0,980 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.45 kW
4.45 kW
El input
0.84 kW
1.46 kW
COP
5.21
3.05
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
201 %
130 %
Prated
4.53 kW
3.84 kW
SCOP
5.10
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.01 kW
3.40 kW
COP Tj = -7°C
3.35
1.98
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.43 kW
2.12 kW
COP Tj = +2°C
5.00
3.37
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.71 kW
1.41 kW
COP Tj = +7°C
6.52
4.14
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.22 kW
2.10 kW
COP Tj = 12°C
11.22
8.16
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
4.01 kW
3.40 kW
COP Tj = Tbiv
3.35
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.38 kW
3.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.65
1.71
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
8 W
8 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.15 kW
0.15 kW
Annual energy consumption Qhe
1835 kWh
2381 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
135 %
COP
3.32
Heating up time
1:58 h:min
Standby power input
26.0 W
Reference hot water temperature
46.0 °C
Mixed water at 40°C
235 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.99 kW
6.11 kW
El input
1.13 kW
1.96 kW
COP
5.26
3.11
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
198 %
133 %
Prated
6.40 kW
5.31 kW
SCOP
5.03
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.66 kW
4.70 kW
COP Tj = -7°C
3.21
2.01
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.35 kW
3.05 kW
COP Tj = +2°C
4.88
3.37
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.05 kW
1.99 kW
COP Tj = +7°C
6.72
4.56
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.22 kW
2.05 kW
COP Tj = 12°C
11.22
7.43
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.66 kW
4.70 kW
COP Tj = Tbiv
3.21
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.29 kW
4.56 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.10 kW
0.80 kW
Annual energy consumption Qhe
2629 kWh
3221 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
136 %
COP
3.32
Heating up time
1:58 h:min
Standby power input
26.0 W
Reference hot water temperature
46.0 °C
Mixed water at 40°C
235 l