Hi -Therma Integra 4 6kW

Certificate Holder
Qingdao Hisense Hitachi Air-conditioning Systems Co.,Ltd.
Qianwangang Road
266555 Qingdao, Shandong
China
Registration number
011-1W0579
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Hi -Therma Integra 4 6kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

0,980 kg

Certification Date
10.02.2023
Testing basis
HP KEYMARK certification scheme rules rev. 11
Generate PDF Export model CSV
  • Number of models 2

Models

AHW-044HCDS1/AHS-044HCDSAA-23
Configure model
Model name
AHW-044HCDS1/AHS-044HCDSAA-23
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.45 kW

4.45 kW

El input

0.84 kW

1.46 kW

COP

5.21

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

201 %

130 %

Prated

4.53 kW

3.84 kW

SCOP

5.10

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.01 kW

3.40 kW

COP Tj = -7°C

3.35

1.98

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.43 kW

2.12 kW

COP Tj = +2°C

5.00

3.37

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.71 kW

1.41 kW

COP Tj = +7°C

6.52

4.14

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.22 kW

2.10 kW

COP Tj = 12°C

11.22

8.16

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.01 kW

3.40 kW

COP Tj = Tbiv

3.35

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.38 kW

3.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

1.71

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

8 W

8 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.15 kW

0.15 kW

Annual energy consumption Qhe

1835 kWh

2381 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

135 %

COP

3.32

Heating up time

1:58 h:min

Standby power input

26.0 W

Reference hot water temperature

46.0 °C

Mixed water at 40°C

235 l

AHW-060HCDS1/AHS-060HCDSAA-23
Configure model
Model name
AHW-060HCDS1/AHS-060HCDSAA-23
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.99 kW

6.11 kW

El input

1.13 kW

1.96 kW

COP

5.26

3.11

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

133 %

Prated

6.40 kW

5.31 kW

SCOP

5.03

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.66 kW

4.70 kW

COP Tj = -7°C

3.21

2.01

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.35 kW

3.05 kW

COP Tj = +2°C

4.88

3.37

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.05 kW

1.99 kW

COP Tj = +7°C

6.72

4.56

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.22 kW

2.05 kW

COP Tj = 12°C

11.22

7.43

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.66 kW

4.70 kW

COP Tj = Tbiv

3.21

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.29 kW

4.56 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.69

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.10 kW

0.80 kW

Annual energy consumption Qhe

2629 kWh

3221 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

136 %

COP

3.32

Heating up time

1:58 h:min

Standby power input

26.0 W

Reference hot water temperature

46.0 °C

Mixed water at 40°C

235 l