Certificate holders

Subtype

PACIFIC H-TECH 60 Tri Taille 17

Certificate Holder
Groupe Atlantic
44 boulevard des Etats-Unis
85000 La Roche Sur Yon
France
Registration number
012-C700182
Certification Body
RISE CERT
Subtype title
PACIFIC H-TECH 60 Tri Taille 17
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

3,800 kg

Certification Date
22.03.2023
Testing basis
EN 14511:2013, EN 16147:2017, EN 14825:2016, EN 12102:2013.
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

PACIFIC H-TECH 60 Tri Taille 17
Configure model
Model name
PACIFIC H-TECH 60 Tri Taille 17
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

17.11 kW

15.53 kW

El input

4.08 kW

5.52 kW

COP

4.19

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

130 %

Prated

18.00 kW

16.50 kW

SCOP

4.11

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.00 kW

15.00 kW

COP Tj = -7°C

2.82

2.10

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

9.70 kW

9.00 kW

COP Tj = +2°C

4.13

3.32

Cdh Tj = +2 °C

0.960

0.980

Pdh Tj = +7°C

6.80 kW

6.30 kW

COP Tj = +7°C

5.01

4.23

Cdh Tj = +7 °C

0.930

0.970

Pdh Tj = 12°C

8.00 kW

7.70 kW

COP Tj = 12°C

6.64

5.95

Cdh Tj = +12 °C

0.920

0.960

Pdh Tj = Tbiv

16.00 kW

15.00 kW

COP Tj = Tbiv

2.82

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.90 kW

12.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

1.76

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.990

WTOL

60 °C

60 °C

Poff

16 W

16 W

PTO

97 W

49 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.10 kW

4.10 kW

Annual energy consumption Qhe

9059 kWh

10232 kWh

PACIFIC H-TECH 60 + Tri Taille 17
Configure model
Model name
PACIFIC H-TECH 60 + Tri Taille 17
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

17.11 kW

15.53 kW

El input

4.08 kW

5.52 kW

COP

4.19

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

130 %

Prated

18.00 kW

16.50 kW

SCOP

4.11

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.00 kW

15.00 kW

COP Tj = -7°C

2.82

2.10

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

9.70 kW

9.00 kW

COP Tj = +2°C

4.13

3.32

Cdh Tj = +2 °C

0.960

0.980

Pdh Tj = +7°C

6.80 kW

6.30 kW

COP Tj = +7°C

5.01

4.23

Cdh Tj = +7 °C

0.930

0.970

Pdh Tj = 12°C

8.00 kW

7.70 kW

COP Tj = 12°C

6.64

5.95

Cdh Tj = +12 °C

0.920

0.960

Pdh Tj = Tbiv

16.00 kW

15.00 kW

COP Tj = Tbiv

2.82

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.90 kW

12.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

1.76

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.990

WTOL

60 °C

60 °C

Poff

16 W

16 W

PTO

97 W

49 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.10 kW

4.10 kW

Annual energy consumption Qhe

9059 kWh

10232 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

109 %

COP

2.56

Heating up time

0:54 h:min

Standby power input

48.0 W

Reference hot water temperature

54.2 °C

Mixed water at 40°C

250 l