4,270 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.15 kW
13.30 kW
El input
1.78 kW
6.43 kW
COP
5.13
2.07
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
224 %
165 %
Prated
10.10 kW
9.75 kW
SCOP
5.68
4.19
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.10 kW
9.75 kW
COP Tj = +2°C
4.19
2.88
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
6.60 kW
6.35 kW
COP Tj = +7°C
5.69
3.87
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
4.48 kW
4.30 kW
COP Tj = 12°C
7.47
5.66
Cdh Tj = +12 °C
0.960
0.960
Pdh Tj = Tbiv
10.10 kW
9.75 kW
COP Tj = Tbiv
4.19
2.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.10 kW
9.75 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.19
2.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
24 W
24 W
PTO
24 W
24 W
PSB
24 W
24 W
PCK
24 W
24 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2375 kWh
3109 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
150 %
127 %
Prated
23.13 kW
22.63 kW
SCOP
3.83
3.26
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
14.00 kW
13.70 kW
COP Tj = -7°C
3.21
2.74
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
8.52 kW
8.37 kW
COP Tj = +2°C
5.67
4.45
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
5.50 kW
5.40 kW
COP Tj = +7°C
6.59
5.57
Cdh Tj = +7 °C
0.960
0.960
Pdh Tj = 12°C
4.37 kW
4.47 kW
COP Tj = 12°C
8.50
7.10
Cdh Tj = +12 °C
0.960
0.980
Pdh Tj = Tbiv
14.00 kW
13.70 kW
COP Tj = Tbiv
3.21
2.74
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.52 kW
9.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.960
0.960
WTOL
60 °C
60 °C
Poff
24 W
24 W
PTO
24 W
24 W
PSB
24 W
24 W
PCK
24 W
24 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
23.13 kW
22.63 kW
Annual energy consumption Qhe
14890 kWh
17120 kWh
Pdh Tj = -15°C (if TOL<-20°C)
COP Tj = -15°C (if TOL<-20°C)
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
151 %
Prated
15.70 kW
15.15 kW
SCOP
4.64
3.85
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
13.89 kW
13.40 kW
COP Tj = -7°C
2.93
2.38
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
8.84 kW
8.51 kW
COP Tj = +2°C
4.69
3.80
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
5.58 kW
5.53 kW
COP Tj = +7°C
6.27
5.42
Cdh Tj = +7 °C
0.960
0.960
Pdh Tj = 12°C
4.43 kW
4.40 kW
COP Tj = 12°C
7.70
6.57
Cdh Tj = +12 °C
0.960
0.960
Pdh Tj = Tbiv
13.89 kW
13.40 kW
COP Tj = Tbiv
2.93
2.38
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.79 kW
12.51 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.960
0.960
WTOL
60 °C
60 °C
Poff
24 W
24 W
PTO
24 W
24 W
PSB
24 W
24 W
PCK
24 W
24 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.91 kW
2.64 kW
Annual energy consumption Qhe
6993 kWh
8129 kWh