4,270 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.10 kW
4.85 kW
El input
0.95 kW
1.50 kW
COP
5.35
3.24
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
201 %
159 %
Prated
5.35 kW
4.98 kW
SCOP
5.11
4.03
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.35 kW
4.98 kW
COP Tj = +2°C
4.29
2.60
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.81 kW
3.77 kW
COP Tj = +7°C
5.65
4.52
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
4.45 kW
4.25 kW
COP Tj = 12°C
7.47
5.65
Cdh Tj = +12 °C
0.960
0.960
Pdh Tj = Tbiv
5.35 kW
4.98 kW
COP Tj = Tbiv
4.29
2.60
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.35 kW
4.98 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.29
2.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
24 W
24 W
PTO
24 W
25 W
PSB
24 W
24 W
PCK
24 W
24 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1400 kWh
1649 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
154 %
125 %
Prated
13.42 kW
13.55 kW
SCOP
3.92
3.20
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
8.12 kW
8.20 kW
COP Tj = -7°C
3.63
2.91
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.85 kW
4.93 kW
COP Tj = +2°C
5.67
4.30
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
3.95 kW
3.80 kW
COP Tj = +7°C
7.10
5.47
Cdh Tj = +7 °C
0.960
0.960
Pdh Tj = 12°C
4.47 kW
4.25 kW
COP Tj = 12°C
8.25
7.10
Cdh Tj = +12 °C
0.960
0.960
Pdh Tj = Tbiv
8.12 kW
8.20 kW
COP Tj = Tbiv
3.63
2.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.41 kW
6.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.00
1.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.960
0.960
WTOL
60 °C
60 °C
Poff
24 W
24 W
PTO
24 W
25 W
PSB
24 W
24 W
PCK
24 W
24 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
13.42 kW
13.55 kW
Annual energy consumption Qhe
8434 kWh
10423 kWh
Pdh Tj = -15°C (if TOL<-20°C)
COP Tj = -15°C (if TOL<-20°C)
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
193 %
141 %
Prated
9.21 kW
9.20 kW
SCOP
4.91
3.59
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.15 kW
8.03 kW
COP Tj = -7°C
3.46
2.39
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
5.08 kW
4.95 kW
COP Tj = +2°C
5.12
3.60
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
3.72 kW
3.65 kW
COP Tj = +7°C
6.21
4.82
Cdh Tj = +7 °C
0.960
0.960
Pdh Tj = 12°C
4.34 kW
4.28 kW
COP Tj = 12°C
8.25
6.64
Cdh Tj = +12 °C
0.960
0.960
Pdh Tj = Tbiv
8.15 kW
8.03 kW
COP Tj = Tbiv
3.46
2.39
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.10 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.98
2.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.960
0.960
WTOL
60 °C
60 °C
Poff
24 W
24 W
PTO
24 W
25 W
PSB
24 W
24 W
PCK
24 W
24 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.11 kW
0.20 kW
Annual energy consumption Qhe
3879 kWh
5299 kWh