Certificate holders

Subtype

EGEA 260 LT - 260 LT-S

Certificate Holder
Ferroli S.p.A.
Via Ritonda 78/A
37047 San Bonifacio (VR)
Italy
Registration number
011-1W0595
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
EGEA 260 LT - 260 LT-S
Driving energy
Electricity
Heat Pump Type
Heat Pump for Domestic Hot Water (DHW)
Refrigerant
R134a
Mass of Refrigerant

1,000 kg

Certification Date
03.05.2023
Testing basis
HP KEYMARK certification scheme rules V11
Generate PDF Export model CSV
  • Number of models 2

Models

EGEA 260 LT
Configure model
Model name
EGEA 260 LT
Units
Indoor
Climate zone (for heating)
Colder + Warmer
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Warmer Climate

EN 12102-2

Sound power level indoor

51 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

160 %

COP

3.90

Heating up time

7:54 h:min

Standby power input

24.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

340 l

Colder Climate

EN 12102-2

Sound power level indoor

51 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

112 %

COP

2.73

Heating up time

12:5 h:min

Standby power input

32.0 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

338 l

Average Climate

EN 12102-2

Sound power level indoor

51 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

138 %

COP

3.37

Heating up time

9:29 h:min

Standby power input

28.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

340 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

EGEA 260 LT-S
Configure model
Model name
EGEA 260 LT-S
Units
Indoor
Climate zone (for heating)
Colder + Warmer
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Warmer Climate

EN 12102-2

Sound power level indoor

51 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

160 %

COP

3.90

Heating up time

7:54 h:min

Standby power input

24.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

340 l

Colder Climate

EN 12102-2

Sound power level indoor

51 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

112 %

COP

2.73

Heating up time

12:5 h:min

Standby power input

32.0 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

338 l

Average Climate

EN 12102-2

Sound power level indoor

51 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

138 %

COP

3.37

Heating up time

9:29 h:min

Standby power input

28.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

335 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed