2,950 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.40 kW
3.84 kW
El input
0.93 kW
1.44 kW
COP
4.74
2.66
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
Sound power level outdoor
55 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
207 %
150 %
Prated
9.00 kW
8.00 kW
SCOP
5.24
3.82
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = -7°C
0.00 kW
0.00 kW
COP Tj = -7°C
0.00
0.00
Pdh Tj = +2°C
8.81 kW
8.32 kW
COP Tj = +2°C
3.18
2.34
Pdh Tj = +7°C
5.77 kW
5.41 kW
COP Tj = +7°C
4.57
3.26
Pdh Tj = 12°C
3.34 kW
3.17 kW
COP Tj = 12°C
6.89
5.11
Pdh Tj = Tbiv
8.81 kW
8.32 kW
COP Tj = Tbiv
3.18
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.81 kW
8.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.18
2.34
Rated airflow rate
0 m³/h
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.98
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2243 kWh
2911 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
Sound power level outdoor
55 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
131 %
102 %
Prated
14.00 kW
11.00 kW
SCOP
3.34
2.62
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-13 °C
Pdh Tj = -7°C
8.62 kW
6.38 kW
COP Tj = -7°C
2.96
2.50
Pdh Tj = +2°C
5.28 kW
3.92 kW
COP Tj = +2°C
4.20
3.48
Pdh Tj = +7°C
3.42 kW
2.79 kW
COP Tj = +7°C
5.87
4.68
Pdh Tj = 12°C
3.35 kW
3.24 kW
COP Tj = 12°C
7.12
5.67
Pdh Tj = Tbiv
8.62 kW
6.38 kW
COP Tj = Tbiv
2.56
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.73 kW
2.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
6.38
Rated airflow rate
0 m³/h
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.98
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
14.24 kW
10.57 kW
Annual energy consumption Qhe
10498 kWh
9932 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
Sound power level outdoor
55 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
163 %
128 %
Prated
10.00 kW
7.00 kW
SCOP
4.14
3.27
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.42 kW
5.87 kW
COP Tj = -7°C
2.76
2.26
Cdh Tj = -7 °C
Pdh Tj = +2°C
5.12 kW
3.52 kW
COP Tj = +2°C
3.94
3.27
Cdh Tj = +2 °C
Pdh Tj = +7°C
3.26 kW
2.72 kW
COP Tj = +7°C
5.53
4.14
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.35 kW
3.20 kW
COP Tj = 12°C
7.09
5.29
Cdh Tj = +12 °C
Pdh Tj = Tbiv
8.42 kW
5.87 kW
COP Tj = Tbiv
2.76
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.37 kW
2.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.88
Rated airflow rate
0 m³/h
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.980
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.63 kW
4.33 kW
Annual energy consumption Qhe
4755 kWh
4199 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.40 kW
3.84 kW
El input
0.93 kW
1.44 kW
COP
4.74
2.66
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
Sound power level outdoor
5 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
133 %
Prated
9.00 kW
8.00 kW
SCOP
4.67
3.41
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = -7°C
0.00 kW
0.00 kW
COP Tj = -7°C
0.00
0.00
Pdh Tj = +2°C
8.81 kW
8.32 kW
COP Tj = +2°C
3.18
2.34
Cdh Tj = +2 °C
Pdh Tj = +7°C
5.77 kW
5.41 kW
COP Tj = +7°C
4.57
3.26
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.34 kW
3.17 kW
COP Tj = 12°C
6.89
5.11
Cdh Tj = +12 °C
Pdh Tj = Tbiv
8.81 kW
8.32 kW
COP Tj = Tbiv
3.18
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.81 kW
8.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.18
2.34
Rated airflow rate
0 m³/h
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.980
WTOL
60 °C
60 °C
Poff
24 W
24 W
PTO
69 W
69 W
PSB
24 W
24 W
PCK
55 W
55 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2517 kWh
3264 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
Sound power level outdoor
55 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
129 %
100 %
Prated
14.00 kW
11.00 kW
SCOP
3.30
2.58
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-13 °C
Pdh Tj = -7°C
8.62 kW
6.38 kW
COP Tj = -7°C
2.96
2.50
Pdh Tj = +2°C
5.28 kW
3.92 kW
COP Tj = +2°C
4.20
3.48
Pdh Tj = +7°C
3.42 kW
2.79 kW
COP Tj = +7°C
5.87
4.68
Pdh Tj = 12°C
3.35 kW
3.24 kW
COP Tj = 12°C
7.12
5.67
Pdh Tj = Tbiv
8.62 kW
6.38 kW
COP Tj = Tbiv
2.56
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.73 kW
2.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
2.09
Rated airflow rate
0 m³/h
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.98
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
14.24 kW
10.57 kW
Annual energy consumption Qhe
10634 kWh
10109 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
Sound power level outdoor
55 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
155 %
121 %
Prated
10.00 kW
7.00 kW
SCOP
3.95
3.10
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.42 kW
5.87 kW
COP Tj = -7°C
2.76
2.26
Cdh Tj = -7 °C
Pdh Tj = +2°C
5.12 kW
3.52 kW
COP Tj = +2°C
3.94
3.27
Cdh Tj = +2 °C
Pdh Tj = +7°C
3.26 kW
2.72 kW
COP Tj = +7°C
5.53
4.14
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.35 kW
3.20 kW
COP Tj = 12°C
7.09
5.29
Cdh Tj = +12 °C
Pdh Tj = Tbiv
8.42 kW
5.87 kW
COP Tj = Tbiv
2.76
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.37 kW
2.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.88
Rated airflow rate
0 m³/h
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.980
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.63 kW
4.33 kW
Annual energy consumption Qhe
4982 kWh
4427 kWh
Heating
EN 14511-2
Medium temperature
Heat output
3.84 kW
El input
1.44 kW
COP
2.66
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Medium temperature
Sound power level indoor
52 dB(A)
Sound power level outdoor
50 dB(A)
EN 14825
Medium temperature
ηs
128 %
Prated
7.00 kW
SCOP
3.27
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
5.87 kW
COP Tj = -7°C
2.26
Cdh Tj = -7 °C
Pdh Tj = +2°C
3.52 kW
COP Tj = +2°C
3.27
Cdh Tj = +2 °C
Pdh Tj = +7°C
2.72 kW
COP Tj = +7°C
4.14
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.20 kW
COP Tj = 12°C
5.29
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.87 kW
COP Tj = Tbiv
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.88
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
WTOL
60 °C
Poff
27 W
PTO
63 W
PSB
27 W
PCK
35 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
4.33 kW
Annual energy consumption Qhe
4199 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
111 %
COP
2.70
Heating up time
02:06 h:min
Standby power input
132.0 W
Reference hot water temperature
57.0 °C
Mixed water at 40°C
352 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.40 kW
3.84 kW
El input
0.93 kW
1.44 kW
COP
4.74
2.66
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
134 %
Prated
7.00 kW
7.00 kW
SCOP
4.53
3.42
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.70 kW
6.89 kW
COP Tj = +2°C
3.38
2.50
Pdh Tj = +7°C
4.31 kW
4.47 kW
COP Tj = +7°C
4.81
3.28
Pdh Tj = 12°C
3.32 kW
3.16 kW
COP Tj = 12°C
6.73
4.98
Pdh Tj = Tbiv
6.70 kW
6.68 kW
COP Tj = Tbiv
3.38
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.70 kW
6.89 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.38
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.98
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1977 kWh
2694 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
135 %
101 %
Prated
9.00 kW
9.00 kW
SCOP
3.45
2.60
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-13 °C
Pdh Tj = -7°C
5.57 kW
5.31 kW
COP Tj = -7°C
3.14
2.52
Pdh Tj = +2°C
3.45 kW
3.28 kW
COP Tj = +2°C
4.51
3.50
Pdh Tj = +7°C
2.89 kW
2.78 kW
COP Tj = +7°C
5.78
4.56
Pdh Tj = 12°C
3.34 kW
3.23 kW
COP Tj = 12°C
6.96
5.59
Pdh Tj = Tbiv
5.57 kW
5.31 kW
COP Tj = Tbiv
3.14
2.52
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.36 kW
2.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.55
2.09
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.98
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.52 kW
8.76 kW
Annual energy consumption Qhe
6605 kWh
8311 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
154 %
121 %
Prated
6.00 kW
6.00 kW
SCOP
3.92
3.11
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.48 kW
5.54 kW
COP Tj = -7°C
2.93
2.26
Cdh Tj = -7 °C
Pdh Tj = +2°C
3.28 kW
3.41 kW
COP Tj = +2°C
4.18
3.27
Cdh Tj = +2 °C
Pdh Tj = +7°C
2.86 kW
2.71 kW
COP Tj = +7°C
5.43
4.09
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.34 kW
3.19 kW
COP Tj = 12°C
6.96
5.29
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.48 kW
5.54 kW
COP Tj = Tbiv
2.93
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.48 kW
2.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.980
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.52 kW
3.55 kW
Annual energy consumption Qhe
3280 kWh
4138 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.40 kW
3.84 kW
El input
0.93 kW
1.44 kW
COP
4.74
2.66
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
134 %
Prated
7.00 kW
7.00 kW
SCOP
4.53
3.42
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.70 kW
6.89 kW
COP Tj = +2°C
3.38
2.50
Pdh Tj = +7°C
4.31 kW
4.47 kW
COP Tj = +7°C
4.81
3.28
Pdh Tj = 12°C
3.32 kW
3.16 kW
COP Tj = 12°C
6.73
4.98
Pdh Tj = Tbiv
6.70 kW
6.89 kW
COP Tj = Tbiv
3.38
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.70 kW
6.89 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.38
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.98
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1977 kWh
2694 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
135 %
101 %
Prated
9.00 kW
9.00 kW
SCOP
3.45
2.60
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
5.57 kW
5.31 kW
COP Tj = -7°C
3.14
2.52
Pdh Tj = +2°C
4.51 kW
3.50 kW
COP Tj = +2°C
4.51
3.50
Pdh Tj = +7°C
2.89 kW
2.78 kW
COP Tj = +7°C
5.78
4.56
Pdh Tj = 12°C
3.34 kW
3.23 kW
COP Tj = 12°C
6.96
5.59
Pdh Tj = Tbiv
5.57 kW
5.31 kW
COP Tj = Tbiv
2.55
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.36 kW
2.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.55
2.09
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.98
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.25 kW
8.76 kW
Annual energy consumption Qhe
6605 kWh
8311 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
154 %
121 %
Prated
6.00 kW
6.00 kW
SCOP
3.92
3.11
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.48 kW
5.54 kW
COP Tj = -7°C
2.93
2.26
Cdh Tj = -7 °C
Pdh Tj = +2°C
3.28 kW
3.41 kW
COP Tj = +2°C
2.93
2.26
Cdh Tj = +2 °C
Pdh Tj = +7°C
2.86 kW
2.71 kW
COP Tj = +7°C
5.43
4.09
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.34 kW
3.19 kW
COP Tj = 12°C
6.96
5.26
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.48 kW
5.54 kW
COP Tj = Tbiv
2.93
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.47 kW
2.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.980
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.53 kW
3.55 kW
Annual energy consumption Qhe
3280 kWh
4138 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.40 kW
3.84 kW
El input
0.93 kW
1.44 kW
COP
4.74
2.66
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
134 %
Prated
7.00 kW
7.00 kW
SCOP
4.53
3.42
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.70 kW
6.89 kW
COP Tj = +2°C
3.38
2.50
Pdh Tj = +7°C
4.31 kW
4.47 kW
COP Tj = +7°C
4.81
3.28
Pdh Tj = 12°C
3.32 kW
3.16 kW
COP Tj = 12°C
6.73
4.98
Pdh Tj = Tbiv
6.70 kW
6.89 kW
COP Tj = Tbiv
3.38
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.70 kW
6.89 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.38
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.98
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1977 kWh
2694 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
135 %
101 %
Prated
9.00 kW
9.00 kW
SCOP
3.45
2.60
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-13 °C
Pdh Tj = -7°C
5.57 kW
5.31 kW
COP Tj = -7°C
3.14
2.52
Pdh Tj = +2°C
3.45 kW
3.28 kW
COP Tj = +2°C
4.51
3.50
Pdh Tj = +7°C
2.89 kW
2.78 kW
COP Tj = +7°C
5.78
4.56
Pdh Tj = 12°C
3.34 kW
3.23 kW
COP Tj = 12°C
6.96
5.59
Pdh Tj = Tbiv
5.57 kW
5.31 kW
COP Tj = Tbiv
3.14
2.52
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.36 kW
2.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.55
2.09
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.98
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.25 kW
8.76 kW
Annual energy consumption Qhe
6605 kWh
8311 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
154 %
121 %
Prated
6.00 kW
6.00 kW
SCOP
3.92
3.11
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.48 kW
5.54 kW
COP Tj = -7°C
2.93
2.26
Cdh Tj = -7 °C
Pdh Tj = +2°C
3.28 kW
3.41 kW
COP Tj = +2°C
4.18
3.27
Cdh Tj = +2 °C
Pdh Tj = +7°C
2.86 kW
2.71 kW
COP Tj = +7°C
5.43
4.09
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.34 kW
3.19 kW
COP Tj = 12°C
6.96
5.26
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.48 kW
5.54 kW
COP Tj = Tbiv
2.93
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.47 kW
2.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.980
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.53 kW
3.55 kW
Annual energy consumption Qhe
3280 kWh
4138 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.40 kW
3.84 kW
El input
0.93 kW
1.44 kW
COP
4.74
2.66
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
207 %
149 %
Prated
7.00 kW
7.00 kW
SCOP
5.25
3.80
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.70 kW
6.89 kW
COP Tj = +2°C
3.38
2.50
Pdh Tj = +7°C
4.31 kW
4.47 kW
COP Tj = +7°C
4.81
3.28
Pdh Tj = 12°C
3.32 kW
3.16 kW
COP Tj = 12°C
6.73
4.98
Pdh Tj = Tbiv
6.70 kW
6.89 kW
COP Tj = Tbiv
3.38
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.70 kW
6.89 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.38
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.98
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1704 kWh
2420 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
138 %
103 %
Prated
9.00 kW
9.00 kW
SCOP
3.53
2.64
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-13 °C
Pdh Tj = -7°C
5.57 kW
5.31 kW
COP Tj = -7°C
3.14
2.52
Pdh Tj = +2°C
3.45 kW
3.28 kW
COP Tj = +2°C
4.51
3.50
Pdh Tj = +7°C
2.89 kW
2.78 kW
COP Tj = +7°C
5.78
4.56
Pdh Tj = 12°C
3.34 kW
3.23 kW
COP Tj = 12°C
6.96
5.59
Pdh Tj = Tbiv
5.57 kW
5.31 kW
COP Tj = Tbiv
3.14
2.52
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.36 kW
2.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.55
2.09
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.98
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.25 kW
8.76 kW
Annual energy consumption Qhe
6468 kWh
8174 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
129 %
Prated
6.00 kW
6.00 kW
SCOP
4.21
3.29
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.48 kW
5.54 kW
COP Tj = -7°C
2.93
2.26
Cdh Tj = -7 °C
Pdh Tj = +2°C
3.28 kW
3.41 kW
COP Tj = +2°C
4.18
3.27
Cdh Tj = +2 °C
Pdh Tj = +7°C
2.86 kW
2.71 kW
COP Tj = +7°C
5.43
4.09
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.34 kW
3.19 kW
COP Tj = 12°C
6.96
5.26
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.48 kW
5.54 kW
COP Tj = Tbiv
2.93
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.47 kW
2.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.980
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.53 kW
3.55 kW
Annual energy consumption Qhe
3052 kWh
3910 kWh
Heating
EN 14511-2
Medium temperature
Heat output
3.84 kW
El input
1.44 kW
COP
2.66
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Medium temperature
Sound power level indoor
52 dB(A)
EN 14825
Medium temperature
ηs
121 %
Prated
6.00 kW
SCOP
3.11
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
5.54 kW
COP Tj = -7°C
2.26
Pdh Tj = +2°C
3.41 kW
COP Tj = +2°C
3.27
Pdh Tj = +7°C
2.71 kW
COP Tj = +7°C
4.09
Pdh Tj = 12°C
3.19 kW
COP Tj = 12°C
5.29
Pdh Tj = Tbiv
5.54 kW
COP Tj = Tbiv
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
WTOL
60 °C
Poff
27 W
PTO
63 W
PSB
27 W
PCK
35 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
3.55 kW
Annual energy consumption Qhe
4138 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
111 %
COP
2.70
Heating up time
02:06 h:min
Standby power input
132.0 W
Reference hot water temperature
57.0 °C
Mixed water at 40°C
352 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.40 kW
3.84 kW
El input
0.93 kW
1.44 kW
COP
4.74
2.66
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
Sound power level outdoor
55 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
207 %
150 %
Prated
9.00 kW
8.00 kW
SCOP
5.24
3.82
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = -7°C
0.00 kW
0.00 kW
COP Tj = -7°C
0.00
0.00
Pdh Tj = +2°C
8.81 kW
8.32 kW
COP Tj = +2°C
3.18
2.34
Pdh Tj = +7°C
5.77 kW
5.41 kW
COP Tj = +7°C
4.57
3.26
Pdh Tj = 12°C
3.34 kW
3.17 kW
COP Tj = 12°C
6.89
5.11
Pdh Tj = Tbiv
8.81 kW
8.32 kW
COP Tj = Tbiv
3.18
2.34
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.81 kW
8.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.18
2.34
Rated airflow rate
0 m³/h
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.98
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2243 kWh
2911 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
Sound power level outdoor
55 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
131 %
102 %
Prated
14.00 kW
11.00 kW
SCOP
3.34
2.62
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-13 °C
Pdh Tj = -7°C
8.62 kW
6.38 kW
COP Tj = -7°C
2.96
2.50
Pdh Tj = +2°C
5.28 kW
3.92 kW
COP Tj = +2°C
4.20
3.48
Pdh Tj = +7°C
3.42 kW
2.79 kW
COP Tj = +7°C
5.87
4.68
Pdh Tj = 12°C
3.35 kW
3.24 kW
COP Tj = 12°C
7.12
5.67
Pdh Tj = Tbiv
8.62 kW
6.38 kW
COP Tj = Tbiv
2.56
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.73 kW
2.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
6.38
Rated airflow rate
0 m³/h
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.98
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
14.24 kW
10.57 kW
Annual energy consumption Qhe
10498 kWh
9932 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
52 dB(A)
52 dB(A)
Sound power level outdoor
55 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
163 %
128 %
Prated
10.00 kW
7.00 kW
SCOP
4.14
3.27
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.42 kW
5.87 kW
COP Tj = -7°C
2.76
2.26
Cdh Tj = -7 °C
Pdh Tj = +2°C
5.12 kW
3.52 kW
COP Tj = +2°C
3.94
3.27
Cdh Tj = +2 °C
Pdh Tj = +7°C
3.26 kW
2.72 kW
COP Tj = +7°C
5.53
4.14
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.35 kW
3.20 kW
COP Tj = 12°C
7.09
5.29
Cdh Tj = +12 °C
Pdh Tj = Tbiv
8.42 kW
5.87 kW
COP Tj = Tbiv
2.76
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.37 kW
2.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.88
Rated airflow rate
0 m³/h
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.980
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
63 W
63 W
PSB
27 W
27 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.63 kW
4.33 kW
Annual energy consumption Qhe
4755 kWh
4199 kWh
Heating
EN 14511-2
Medium temperature
Heat output
3.84 kW
El input
1.44 kW
COP
2.66
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Medium temperature
Sound power level indoor
52 dB(A)
Sound power level outdoor
50 dB(A)
EN 14825
Medium temperature
ηs
128 %
Prated
7.00 kW
SCOP
3.27
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
5.87 kW
COP Tj = -7°C
2.26
Cdh Tj = -7 °C
Pdh Tj = +2°C
3.52 kW
COP Tj = +2°C
3.27
Cdh Tj = +2 °C
Pdh Tj = +7°C
2.72 kW
COP Tj = +7°C
4.14
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.20 kW
COP Tj = 12°C
5.29
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.87 kW
COP Tj = Tbiv
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.88
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
WTOL
60 °C
Poff
27 W
PTO
63 W
PSB
27 W
PCK
35 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
4.33 kW
Annual energy consumption Qhe
4199 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
111 %
COP
2.70
Heating up time
02:06 h:min
Standby power input
132.0 W
Reference hot water temperature
57.0 °C
Mixed water at 40°C
352 l
Heating
EN 14511-2
Medium temperature
Heat output
3.84 kW
El input
1.44 kW
COP
2.66
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Medium temperature
Sound power level indoor
52 dB(A)
EN 14825
Medium temperature
ηs
121 %
Prated
6.00 kW
SCOP
3.11
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
5.54 kW
COP Tj = -7°C
2.26
Pdh Tj = +2°C
3.41 kW
COP Tj = +2°C
3.27
Pdh Tj = +7°C
2.71 kW
COP Tj = +7°C
4.09
Pdh Tj = 12°C
3.19 kW
COP Tj = 12°C
5.29
Pdh Tj = Tbiv
5.54 kW
COP Tj = Tbiv
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
WTOL
60 °C
Poff
27 W
PTO
63 W
PSB
27 W
PCK
35 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
3.55 kW
Annual energy consumption Qhe
4138 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
111 %
COP
2.70
Heating up time
02:06 h:min
Standby power input
132.0 W
Reference hot water temperature
57.0 °C
Mixed water at 40°C
352 l
Heating
EN 14511-2
Medium temperature
Heat output
3.84 kW
El input
1.44 kW
COP
2.66
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Medium temperature
Sound power level indoor
52 dB(A)
EN 14825
Medium temperature
ηs
121 %
Prated
6.00 kW
SCOP
3.11
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
5.54 kW
COP Tj = -7°C
2.26
Pdh Tj = +2°C
3.41 kW
COP Tj = +2°C
3.27
Pdh Tj = +7°C
2.71 kW
COP Tj = +7°C
4.09
Pdh Tj = 12°C
3.19 kW
COP Tj = 12°C
5.29
Pdh Tj = Tbiv
5.54 kW
COP Tj = Tbiv
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
WTOL
60 °C
Poff
27 W
PTO
63 W
PSB
27 W
PCK
35 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
3.55 kW
Annual energy consumption Qhe
4138 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
111 %
COP
2.70
Heating up time
02:06 h:min
Standby power input
132.0 W
Reference hot water temperature
57.0 °C
Mixed water at 40°C
352 l