2,300 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
13.21 kW
11.99 kW
El input
2.73 kW
3.93 kW
COP
4.83
3.04
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
202 %
141 %
Prated
13.00 kW
12.00 kW
SCOP
5.25
3.73
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.20 kW
12.00 kW
COP Tj = +2°C
4.84
3.05
Cdh Tj = +2 °C
Pdh Tj = +7°C
13.30 kW
12.40 kW
COP Tj = +7°C
5.13
3.45
Cdh Tj = +7 °C
Pdh Tj = 12°C
13.50 kW
12.90 kW
COP Tj = 12°C
5.61
4.23
Cdh Tj = +12 °C
Pdh Tj = Tbiv
13.20 kW
12.00 kW
COP Tj = Tbiv
4.84
3.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.20 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.84
3.05
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
84 W
84 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3361 kWh
4287 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
208 %
147 %
Prated
16.00 kW
15.00 kW
SCOP
5.39
3.88
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
13.40 kW
12.50 kW
COP Tj = -7°C
5.25
3.68
Cdh Tj = -7 °C
Pdh Tj = +2°C
13.50 kW
12.80 kW
COP Tj = +2°C
5.59
4.08
Cdh Tj = +2 °C
Pdh Tj = +7°C
13.60 kW
13.00 kW
COP Tj = +7°C
5.78
4.44
Cdh Tj = +7 °C
Pdh Tj = 12°C
13.60 kW
13.20 kW
COP Tj = 12°C
5.82
4.75
Cdh Tj = +12 °C
Pdh Tj = Tbiv
13.40 kW
12.40 kW
COP Tj = Tbiv
5.25
3.46
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.40 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.25
3.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
84 W
84 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.60 kW
3.16 kW
Annual energy consumption Qhe
7507 kWh
9647 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
203 %
142 %
Prated
13.00 kW
12.00 kW
SCOP
5.26
3.75
Tbiv
-10 °C
-10 °C
TOL
-20 °C
-10 °C
Pdh Tj = -7°C
13.20 kW
12.10 kW
COP Tj = -7°C
4.89
3.18
Cdh Tj = -7 °C
Pdh Tj = +2°C
13.40 kW
12.50 kW
COP Tj = +2°C
5.20
3.69
Cdh Tj = +2 °C
Pdh Tj = +7°C
13.50 kW
12.80 kW
COP Tj = +7°C
5.50
4.08
Cdh Tj = +7 °C
Pdh Tj = 12°C
13.60 kW
13.10 kW
COP Tj = 12°C
5.84
4.54
Cdh Tj = +12 °C
Pdh Tj = Tbiv
13.20 kW
12.00 kW
COP Tj = Tbiv
4.84
3.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.20 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.84
3.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
84 W
84 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5186 kWh
6603 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
13.21 kW
11.99 kW
El input
2.73 kW
3.93 kW
COP
4.83
3.04
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
202 %
141 %
Prated
13.00 kW
12.00 kW
SCOP
5.25
3.73
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.20 kW
12.00 kW
COP Tj = +2°C
4.84
3.05
Cdh Tj = +2 °C
Pdh Tj = +7°C
13.30 kW
12.40 kW
COP Tj = +7°C
5.13
3.45
Cdh Tj = +7 °C
Pdh Tj = 12°C
13.50 kW
12.90 kW
COP Tj = 12°C
5.61
4.23
Cdh Tj = +12 °C
Pdh Tj = Tbiv
13.20 kW
12.00 kW
COP Tj = Tbiv
4.84
3.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.20 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.84
3.05
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
84 W
84 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3361 kWh
4287 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
208 %
147 %
Prated
16.00 kW
15.00 kW
SCOP
5.39
3.88
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
13.40 kW
12.50 kW
COP Tj = -7°C
5.25
3.68
Cdh Tj = -7 °C
Pdh Tj = +2°C
13.50 kW
12.80 kW
COP Tj = +2°C
5.59
4.08
Cdh Tj = +2 °C
Pdh Tj = +7°C
13.60 kW
13.00 kW
COP Tj = +7°C
5.78
4.44
Cdh Tj = +7 °C
Pdh Tj = 12°C
13.60 kW
13.20 kW
COP Tj = 12°C
5.82
4.75
Cdh Tj = +12 °C
Pdh Tj = Tbiv
13.40 kW
12.40 kW
COP Tj = Tbiv
5.25
3.46
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.40 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.25
3.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
84 W
84 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.60 kW
3.16 kW
Annual energy consumption Qhe
7507 kWh
9647 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
203 %
142 %
Prated
13.00 kW
12.00 kW
SCOP
5.26
3.75
Tbiv
-10 °C
-10 °C
TOL
-20 °C
-10 °C
Pdh Tj = -7°C
13.20 kW
12.10 kW
COP Tj = -7°C
4.89
3.18
Cdh Tj = -7 °C
Pdh Tj = +2°C
13.40 kW
12.50 kW
COP Tj = +2°C
5.20
3.69
Cdh Tj = +2 °C
Pdh Tj = +7°C
13.50 kW
12.80 kW
COP Tj = +7°C
5.50
4.08
Cdh Tj = +7 °C
Pdh Tj = 12°C
13.60 kW
13.10 kW
COP Tj = 12°C
5.84
4.54
Cdh Tj = +12 °C
Pdh Tj = Tbiv
13.20 kW
12.00 kW
COP Tj = Tbiv
4.84
3.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.20 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.84
3.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
84 W
84 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5186 kWh
6603 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
13.21 kW
11.99 kW
El input
2.73 kW
3.93 kW
COP
4.83
3.04
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
202 %
141 %
Prated
13.00 kW
12.00 kW
SCOP
5.25
3.73
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.20 kW
12.00 kW
COP Tj = +2°C
4.84
3.05
Cdh Tj = +2 °C
Pdh Tj = +7°C
13.30 kW
12.40 kW
COP Tj = +7°C
5.13
3.45
Cdh Tj = +7 °C
Pdh Tj = 12°C
13.50 kW
12.90 kW
COP Tj = 12°C
5.61
4.23
Cdh Tj = +12 °C
Pdh Tj = Tbiv
13.20 kW
12.00 kW
COP Tj = Tbiv
4.84
3.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.20 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.84
3.05
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
84 W
84 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3361 kWh
4287 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
208 %
147 %
Prated
16.00 kW
15.00 kW
SCOP
5.39
3.88
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
13.40 kW
12.50 kW
COP Tj = -7°C
5.25
3.68
Cdh Tj = -7 °C
Pdh Tj = +2°C
13.50 kW
12.80 kW
COP Tj = +2°C
5.59
4.08
Cdh Tj = +2 °C
Pdh Tj = +7°C
13.60 kW
13.00 kW
COP Tj = +7°C
5.78
4.44
Cdh Tj = +7 °C
Pdh Tj = 12°C
13.60 kW
13.20 kW
COP Tj = 12°C
5.82
4.75
Cdh Tj = +12 °C
Pdh Tj = Tbiv
13.40 kW
12.40 kW
COP Tj = Tbiv
5.25
3.46
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.40 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.25
3.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
84 W
84 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.60 kW
3.16 kW
Annual energy consumption Qhe
7507 kWh
9647 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
203 %
142 %
Prated
13.00 kW
12.00 kW
SCOP
5.26
3.75
Tbiv
-10 °C
-10 °C
TOL
-20 °C
-10 °C
Pdh Tj = -7°C
13.20 kW
12.10 kW
COP Tj = -7°C
4.89
3.18
Cdh Tj = -7 °C
Pdh Tj = +2°C
13.40 kW
12.50 kW
COP Tj = +2°C
5.20
3.69
Cdh Tj = +2 °C
Pdh Tj = +7°C
13.50 kW
12.80 kW
COP Tj = +7°C
5.50
4.08
Cdh Tj = +7 °C
Pdh Tj = 12°C
13.60 kW
13.10 kW
COP Tj = 12°C
5.84
4.54
Cdh Tj = +12 °C
Pdh Tj = Tbiv
13.20 kW
12.00 kW
COP Tj = Tbiv
4.84
3.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.20 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.84
3.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
84 W
84 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5186 kWh
6603 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
13.21 kW
11.90 kW
El input
2.73 kW
3.93 kW
COP
4.83
3.04
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
202 %
141 %
Prated
13.00 kW
12.00 kW
SCOP
5.25
3.73
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.20 kW
12.00 kW
COP Tj = +2°C
4.84
3.05
Cdh Tj = +2 °C
Pdh Tj = +7°C
13.30 kW
12.40 kW
COP Tj = +7°C
5.13
3.45
Cdh Tj = +7 °C
Pdh Tj = 12°C
13.50 kW
12.90 kW
COP Tj = 12°C
5.61
4.23
Cdh Tj = +12 °C
Pdh Tj = Tbiv
13.20 kW
12.00 kW
COP Tj = Tbiv
4.84
3.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.20 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.84
3.05
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
84 W
84 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3361 kWh
4287 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
208 %
147 %
Prated
16.00 kW
15.00 kW
SCOP
5.39
3.88
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
13.40 kW
12.50 kW
COP Tj = -7°C
5.25
3.68
Cdh Tj = -7 °C
Pdh Tj = +2°C
13.50 kW
12.80 kW
COP Tj = +2°C
5.59
4.08
Cdh Tj = +2 °C
Pdh Tj = +7°C
13.60 kW
13.00 kW
COP Tj = +7°C
5.78
4.44
Cdh Tj = +7 °C
Pdh Tj = 12°C
13.60 kW
13.20 kW
COP Tj = 12°C
5.82
4.75
Cdh Tj = +12 °C
Pdh Tj = Tbiv
13.40 kW
12.40 kW
COP Tj = Tbiv
5.25
3.46
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.40 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.25
3.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
84 W
84 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.60 kW
3.16 kW
Annual energy consumption Qhe
7507 kWh
9647 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
203 %
142 %
Prated
13.00 kW
12.00 kW
SCOP
5.26
3.75
Tbiv
-10 °C
-10 °C
TOL
-20 °C
-10 °C
Pdh Tj = -7°C
13.20 kW
12.10 kW
COP Tj = -7°C
4.89
3.18
Cdh Tj = -7 °C
Pdh Tj = +2°C
13.40 kW
12.50 kW
COP Tj = +2°C
5.20
3.69
Cdh Tj = +2 °C
Pdh Tj = +7°C
13.50 kW
12.80 kW
COP Tj = +7°C
5.50
4.08
Cdh Tj = +7 °C
Pdh Tj = 12°C
13.60 kW
5.84 kW
COP Tj = 12°C
4.23
4.54
Cdh Tj = +12 °C
Pdh Tj = Tbiv
13.20 kW
12.00 kW
COP Tj = Tbiv
4.84
3.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.20 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.84
3.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
84 W
84 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5186 kWh
6603 kWh