2,500 kg
Heating
EN 14511-2
Heat output
12.59 kW
El input
2.85 kW
COP
4.42
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
failed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Sound power level indoor
60 dB(A)
EN 14825
ηs
189 %
Prated
13.00 kW
SCOP
4.94
Tbiv
2 °C
TOL
0 °C
Pdh Tj = +2°C
12.60 kW
COP Tj = +2°C
4.42
Cdh Tj = +2 °C
0.900
Pdh Tj = +7°C
12.70 kW
COP Tj = +7°C
4.76
Cdh Tj = +7 °C
0.900
Pdh Tj = 12°C
12.90 kW
COP Tj = 12°C
5.34
Cdh Tj = +12 °C
0.900
Pdh Tj = Tbiv
12.60 kW
COP Tj = Tbiv
4.42
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.42
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
Poff
0 W
PTO
78 W
PSB
3 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.40 kW
Annual energy consumption Qhe
3407 kWh
Colder Climate
EN 12102-1
Sound power level indoor
60 dB(A)
EN 14825
ηs
196 %
Prated
16.00 kW
SCOP
5.10
Tbiv
-15 °C
TOL
-22 °C
Pdh Tj = -7°C
12.80 kW
COP Tj = -7°C
5.02
Cdh Tj = -7 °C
0.900
Pdh Tj = +2°C
12.80 kW
COP Tj = +2°C
5.31
Cdh Tj = +2 °C
0.900
Pdh Tj = +7°C
12.90 kW
COP Tj = +7°C
5.56
Cdh Tj = +7 °C
0.900
Pdh Tj = 12°C
12.90 kW
COP Tj = 12°C
5.60
Cdh Tj = +12 °C
0.900
Pdh Tj = Tbiv
12.70 kW
COP Tj = Tbiv
4.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
Poff
0 W
PTO
78 W
PSB
3 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
3.30 kW
Annual energy consumption Qhe
7542 kWh
Pdh Tj = -15°C (if TOL<-20°C)
12.70
COP Tj = -15°C (if TOL<-20°C)
4.90
Cdh Tj = -15 °C
0.90
Average Climate
EN 12102-1
Sound power level indoor
60 dB(A)
EN 14825
ηs
189 %
Prated
13.00 kW
SCOP
4.92
Tbiv
-10 °C
TOL
-20 °C
Pdh Tj = -7°C
12.60 kW
COP Tj = -7°C
4.48
Cdh Tj = -7 °C
0.900
Pdh Tj = +2°C
12.70 kW
COP Tj = +2°C
4.84
Cdh Tj = +2 °C
0.900
Pdh Tj = +7°C
12.80 kW
COP Tj = +7°C
5.21
Cdh Tj = +7 °C
0.900
Pdh Tj = 12°C
12.90 kW
COP Tj = 12°C
5.63
Cdh Tj = +12 °C
0.900
Pdh Tj = Tbiv
12.60 kW
COP Tj = Tbiv
4.42
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.42
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
Poff
0 W
PTO
78 W
PSB
3 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.40 kW
Annual energy consumption Qhe
5285 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.59 kW
11.60 kW
El input
2.85 kW
4.52 kW
COP
4.42
2.57
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
failed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
189 %
122 %
Prated
13.00 kW
12.00 kW
SCOP
4.92
3.26
Tbiv
-10 °C
-10 °C
TOL
-20 °C
-10 °C
Pdh Tj = -7°C
12.60 kW
11.70 kW
COP Tj = -7°C
4.48
2.69
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
12.70 kW
12.00 kW
COP Tj = +2°C
4.84
3.20
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
12.80 kW
12.30 kW
COP Tj = +7°C
5.21
3.60
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
12.90 kW
12.50 kW
COP Tj = 12°C
5.63
4.09
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.60 kW
11.60 kW
COP Tj = Tbiv
4.42
2.57
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.60 kW
11.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.42
2.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
0 W
0 W
PTO
78 W
78 W
PSB
3 W
3 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.40 kW
0.00 kW
Annual energy consumption Qhe
5285 kWh
7350 kWh