1,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.82 kW
5.19 kW
El input
1.21 kW
1.85 kW
COP
4.80
2.81
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
0 dB(A)
0 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
134 %
Prated
6.00 kW
5.00 kW
SCOP
5.32
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.80 kW
5.30 kW
COP Tj = -7°C
4.87
2.94
Pdh Tj = +2°C
5.90 kW
5.50 kW
COP Tj = +2°C
5.24
3.49
Pdh Tj = +7°C
6.00 kW
5.60 kW
COP Tj = +7°C
5.61
3.92
Pdh Tj = 12°C
6.00 kW
5.70 kW
COP Tj = 12°C
6.03
4.44
Pdh Tj = Tbiv
5.80 kW
5.20 kW
COP Tj = Tbiv
4.81
2.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
5.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.81
2.81
Rated airflow rate
0 m³/h
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
54 W
54 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2262 kWh
3017 kWh
Heating
EN 14511-2
Heat output
5.82 kW
El input
1.21 kW
COP
4.80
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Warmer Climate
EN 12102-1
Sound power level indoor
47 dB(A)
Sound power level outdoor
0 dB(A)
EN 14825
ηs
203 %
Prated
6.00 kW
SCOP
5.28
Tbiv
2 °C
TOL
0 °C
Pdh Tj = -7°C
0.00 kW
COP Tj = -7°C
0.00
Pdh Tj = +2°C
5.80 kW
COP Tj = +2°C
4.81
Cdh Tj = +2 °C
Pdh Tj = +7°C
5.90 kW
COP Tj = +7°C
5.16
Cdh Tj = +7 °C
Pdh Tj = 12°C
6.00 kW
COP Tj = 12°C
5.75
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.80 kW
COP Tj = Tbiv
4.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.81
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
65 °C
Poff
0 W
PTO
54 W
PSB
9 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.20 kW
Annual energy consumption Qhe
1473 kWh
Colder Climate
EN 12102-1
Sound power level indoor
47 dB(A)
Sound power level outdoor
0 dB(A)
EN 14825
ηs
212 %
Prated
7.00 kW
SCOP
5.49
Tbiv
-15 °C
TOL
-22 °C
Pdh Tj = -7°C
5.90 kW
COP Tj = -7°C
5.43
Cdh Tj = -7 °C
Pdh Tj = +2°C
6.00 kW
COP Tj = +2°C
5.72
Cdh Tj = +2 °C
Pdh Tj = +7°C
6.00 kW
COP Tj = +7°C
5.97
Cdh Tj = +7 °C
Pdh Tj = 12°C
6.00 kW
COP Tj = 12°C
6.01
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.90 kW
COP Tj = Tbiv
5.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.31
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
65 °C
Poff
0 W
PTO
54 W
PSB
9 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
1.10 kW
Annual energy consumption Qhe
3254 kWh
Average Climate
EN 12102-1
Sound power level indoor
47 dB(A)
Sound power level outdoor
0 dB(A)
EN 14825
ηs
205 %
Prated
6.00 kW
SCOP
5.32
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
5.80 kW
COP Tj = -7°C
4.87
Pdh Tj = +2°C
5.90 kW
COP Tj = +2°C
5.24
Pdh Tj = +7°C
6.00 kW
COP Tj = +7°C
5.61
Pdh Tj = 12°C
6.00 kW
COP Tj = 12°C
6.03
Pdh Tj = Tbiv
5.80 kW
COP Tj = Tbiv
4.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.81
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
WTOL
65 °C
Poff
0 W
PTO
54 W
PSB
9 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
2262 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.82 kW
5.19 kW
El input
1.21 kW
1.85 kW
COP
4.80
2.81
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
47 dB(A)
47 dB(A)
Sound power level outdoor
0 dB(A)
0 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
134 %
Prated
6.00 kW
5.00 kW
SCOP
5.32
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.80 kW
5.30 kW
COP Tj = -7°C
4.87
2.94
Pdh Tj = +2°C
5.90 kW
5.50 kW
COP Tj = +2°C
5.24
3.49
Pdh Tj = +7°C
6.00 kW
5.60 kW
COP Tj = +7°C
5.61
3.92
Pdh Tj = 12°C
6.00 kW
5.70 kW
COP Tj = 12°C
6.03
4.44
Pdh Tj = Tbiv
5.80 kW
5.20 kW
COP Tj = Tbiv
4.81
2.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
5.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.81
2.81
Rated airflow rate
0 m³/h
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
54 W
54 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2262 kWh
3017 kWh
Heating
EN 14511-2
Heat output
5.82 kW
El input
1.21 kW
COP
4.80
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Warmer Climate
EN 12102-1
Sound power level indoor
46 dB(A)
Sound power level outdoor
0 dB(A)
EN 14825
ηs
203 %
Prated
6.00 kW
SCOP
5.28
Tbiv
2 °C
TOL
0 °C
Pdh Tj = -7°C
0.00 kW
COP Tj = -7°C
0.00
Pdh Tj = +2°C
5.80 kW
COP Tj = +2°C
4.81
Cdh Tj = +2 °C
Pdh Tj = +7°C
5.90 kW
COP Tj = +7°C
5.16
Cdh Tj = +7 °C
Pdh Tj = 12°C
6.00 kW
COP Tj = 12°C
5.75
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.80 kW
COP Tj = Tbiv
4.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.81
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
65 °C
Poff
0 W
PTO
54 W
PSB
9 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.20 kW
Annual energy consumption Qhe
1473 kWh
Colder Climate
EN 12102-1
Sound power level indoor
46 dB(A)
Sound power level outdoor
0 dB(A)
EN 14825
ηs
212 %
Prated
7.00 kW
SCOP
5.49
Tbiv
-15 °C
TOL
-22 °C
Pdh Tj = -7°C
5.90 kW
COP Tj = -7°C
5.43
Cdh Tj = -7 °C
Pdh Tj = +2°C
6.00 kW
COP Tj = +2°C
5.72
Cdh Tj = +2 °C
Pdh Tj = +7°C
6.00 kW
COP Tj = +7°C
5.97
Cdh Tj = +7 °C
Pdh Tj = 12°C
6.00 kW
COP Tj = 12°C
6.01
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.90 kW
COP Tj = Tbiv
5.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.31
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
65 °C
Poff
0 W
PTO
54 W
PSB
9 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
1.10 kW
Annual energy consumption Qhe
3254 kWh
Average Climate
EN 12102-1
Sound power level indoor
46 dB(A)
Sound power level outdoor
0 dB(A)
EN 14825
ηs
205 %
Prated
6.00 kW
SCOP
5.32
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
5.80 kW
COP Tj = -7°C
4.87
Pdh Tj = +2°C
5.90 kW
COP Tj = +2°C
5.24
Pdh Tj = +7°C
6.00 kW
COP Tj = +7°C
5.61
Pdh Tj = 12°C
6.00 kW
COP Tj = 12°C
6.03
Pdh Tj = Tbiv
5.80 kW
COP Tj = Tbiv
4.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.81
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
WTOL
65 °C
Poff
0 W
PTO
54 W
PSB
9 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
2262 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.82 kW
5.19 kW
El input
1.21 kW
1.85 kW
COP
4.80
2.81
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
Sound power level outdoor
0 dB(A)
0 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
134 %
Prated
6.00 kW
5.00 kW
SCOP
5.32
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.80 kW
5.30 kW
COP Tj = -7°C
4.87
2.94
Pdh Tj = +2°C
5.90 kW
5.50 kW
COP Tj = +2°C
5.24
3.49
Pdh Tj = +7°C
6.00 kW
5.60 kW
COP Tj = +7°C
5.61
3.92
Pdh Tj = 12°C
6.00 kW
5.70 kW
COP Tj = 12°C
6.03
4.44
Pdh Tj = Tbiv
5.80 kW
5.20 kW
COP Tj = Tbiv
4.81
2.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
5.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.81
2.81
Rated airflow rate
0 m³/h
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
54 W
54 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2262 kWh
3017 kWh
Heating
EN 14511-2
Heat output
5.82 kW
El input
1.21 kW
COP
4.80
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Warmer Climate
EN 12102-1
Sound power level indoor
46 dB(A)
Sound power level outdoor
0 dB(A)
EN 14825
ηs
203 %
Prated
6.00 kW
SCOP
5.28
Tbiv
2 °C
TOL
0 °C
Pdh Tj = -7°C
0.00 kW
COP Tj = -7°C
0.00
Pdh Tj = +2°C
5.80 kW
COP Tj = +2°C
4.81
Cdh Tj = +2 °C
Pdh Tj = +7°C
5.90 kW
COP Tj = +7°C
5.16
Cdh Tj = +7 °C
Pdh Tj = 12°C
6.00 kW
COP Tj = 12°C
5.75
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.80 kW
COP Tj = Tbiv
4.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.81
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
65 °C
Poff
0 W
PTO
54 W
PSB
9 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.20 kW
Annual energy consumption Qhe
1473 kWh
Colder Climate
EN 12102-1
Sound power level indoor
46 dB(A)
Sound power level outdoor
0 dB(A)
EN 14825
ηs
212 %
Prated
7.00 kW
SCOP
5.49
Tbiv
-15 °C
TOL
-22 °C
Pdh Tj = -7°C
5.90 kW
COP Tj = -7°C
5.43
Cdh Tj = -7 °C
Pdh Tj = +2°C
6.00 kW
COP Tj = +2°C
5.72
Cdh Tj = +2 °C
Pdh Tj = +7°C
6.00 kW
COP Tj = +7°C
5.97
Cdh Tj = +7 °C
Pdh Tj = 12°C
6.00 kW
COP Tj = 12°C
6.01
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.90 kW
COP Tj = Tbiv
5.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.31
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
65 °C
Poff
0 W
PTO
54 W
PSB
9 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
1.10 kW
Annual energy consumption Qhe
3254 kWh
Average Climate
EN 12102-1
Sound power level indoor
46 dB(A)
Sound power level outdoor
0 dB(A)
EN 14825
ηs
205 %
Prated
6.00 kW
SCOP
5.32
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
5.80 kW
COP Tj = -7°C
4.87
Pdh Tj = +2°C
5.90 kW
COP Tj = +2°C
5.24
Pdh Tj = +7°C
6.00 kW
COP Tj = +7°C
5.61
Pdh Tj = 12°C
6.00 kW
COP Tj = 12°C
6.03
Pdh Tj = Tbiv
5.80 kW
COP Tj = Tbiv
4.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.81
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
WTOL
65 °C
Poff
0 W
PTO
54 W
PSB
9 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
2262 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.82 kW
5.19 kW
El input
1.21 kW
1.85 kW
COP
4.80
2.81
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
47 dB(A)
47 dB(A)
Sound power level outdoor
0 dB(A)
0 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
134 %
Prated
6.00 kW
5.00 kW
SCOP
5.32
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.80 kW
5.30 kW
COP Tj = -7°C
4.87
2.94
Pdh Tj = +2°C
5.90 kW
5.50 kW
COP Tj = +2°C
5.24
3.49
Pdh Tj = +7°C
6.00 kW
5.60 kW
COP Tj = +7°C
5.61
3.92
Pdh Tj = 12°C
6.00 kW
5.70 kW
COP Tj = 12°C
6.03
4.44
Pdh Tj = Tbiv
5.80 kW
5.20 kW
COP Tj = Tbiv
4.81
2.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
5.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.81
2.81
Rated airflow rate
0 m³/h
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
54 W
54 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2262 kWh
3017 kWh
Heating
EN 14511-2
Heat output
5.82 kW
El input
1.21 kW
COP
4.80
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Warmer Climate
EN 12102-1
Sound power level indoor
47 dB(A)
Sound power level outdoor
0 dB(A)
EN 14825
ηs
203 %
Prated
6.00 kW
SCOP
5.28
Tbiv
2 °C
TOL
0 °C
Pdh Tj = -7°C
0.00 kW
COP Tj = -7°C
0.00
Pdh Tj = +2°C
5.80 kW
COP Tj = +2°C
4.81
Cdh Tj = +2 °C
Pdh Tj = +7°C
5.90 kW
COP Tj = +7°C
5.16
Cdh Tj = +7 °C
Pdh Tj = 12°C
6.00 kW
COP Tj = 12°C
5.75
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.80 kW
COP Tj = Tbiv
4.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.81
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
65 °C
Poff
0 W
PTO
54 W
PSB
9 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.20 kW
Annual energy consumption Qhe
1473 kWh
Colder Climate
EN 12102-1
Sound power level indoor
47 dB(A)
Sound power level outdoor
0 dB(A)
EN 14825
ηs
212 %
Prated
7.00 kW
SCOP
5.49
Tbiv
-15 °C
TOL
-22 °C
Pdh Tj = -7°C
5.90 kW
COP Tj = -7°C
5.43
Cdh Tj = -7 °C
Pdh Tj = +2°C
6.00 kW
COP Tj = +2°C
5.72
Cdh Tj = +2 °C
Pdh Tj = +7°C
6.00 kW
COP Tj = +7°C
5.97
Cdh Tj = +7 °C
Pdh Tj = 12°C
6.00 kW
COP Tj = 12°C
6.01
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.90 kW
COP Tj = Tbiv
5.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.31
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
65 °C
Poff
0 W
PTO
54 W
PSB
9 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
1.10 kW
Annual energy consumption Qhe
3254 kWh
Average Climate
EN 12102-1
Sound power level indoor
47 dB(A)
Sound power level outdoor
0 dB(A)
EN 14825
ηs
205 %
Prated
6.00 kW
SCOP
5.32
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
5.80 kW
COP Tj = -7°C
4.87
Pdh Tj = +2°C
5.90 kW
COP Tj = +2°C
5.24
Pdh Tj = +7°C
6.00 kW
COP Tj = +7°C
5.61
Pdh Tj = 12°C
6.00 kW
COP Tj = 12°C
6.03
Pdh Tj = Tbiv
5.80 kW
COP Tj = Tbiv
4.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.81
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
WTOL
65 °C
Poff
0 W
PTO
54 W
PSB
9 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
2262 kWh