2,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.00 kW
7.66 kW
El input
2.12 kW
2.82 kW
COP
4.25
2.72
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
69 dB(A)
69 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
174 %
117 %
Prated
5.60 kW
5.50 kW
SCOP
4.42
3.01
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.00 kW
4.90 kW
COP Tj = -7°C
2.67
1.77
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.00 kW
3.00 kW
COP Tj = +2°C
4.47
3.02
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.20 kW
2.30 kW
COP Tj = +7°C
5.74
3.90
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.00 kW
2.20 kW
COP Tj = 12°C
8.27
4.90
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.60 kW
5.50 kW
COP Tj = Tbiv
2.31
1.59
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.60 kW
5.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.31
1.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
55 °C
55 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2660 kWh
3885 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
105 %
COP
2.60
Heating up time
2:30 h:min
Standby power input
85.0 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
290 l