Certificate holders

Subtype

HPMO2-16/23

Certificate Holder
Kospel spółka z o.o.
ul. Olchowa 1,
75-136 Koszalin
Poland
Registration number
041-K050-03
Certification Body
BRE Global Limited
Subtype title
HPMO2-16/23
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,000 kg

Certification Date
03.05.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

HPMO2-16/23
Configure model
Model name
HPMO2-16/23
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

17.17 kW

15.05 kW

El input

3.55 kW

5.36 kW

COP

4.83

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

135 %

Prated

13.09 kW

14.42 kW

SCOP

4.62

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.58 kW

12.75 kW

COP Tj = -7°C

3.27

2.18

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.32 kW

7.77 kW

COP Tj = +2°C

4.38

3.28

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.27 kW

7.27 kW

COP Tj = +7°C

5.66

4.56

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

7.71 kW

6.87 kW

COP Tj = 12°C

8.24

6.70

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

11.58 kW

12.75 kW

COP Tj = Tbiv

3.27

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.87 kW

13.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.93

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

51 °C

51 °C

Poff

24 W

24 W

PTO

24 W

24 W

PSB

24 W

24 W

PCK

40 W

40 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.22 kW

0.44 kW

Annual energy consumption Qhe

5850 kWh

8613 kWh