1,000 kg
Domestic Hot Water (DHW)
Warmer Climate
EN 12102-2
Sound power level indoor
53 dB(A)
EN 16147
Declared load profile
L
Efficiency ηDHW
162 %
COP
3.89
Heating up time
5:29 h:min
Standby power input
22.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
247 l
Colder Climate
EN 12102-2
Sound power level indoor
53 dB(A)
EN 16147
Declared load profile
L
Efficiency ηDHW
106 %
COP
2.55
Heating up time
7:44 h:min
Standby power input
30.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
248 l
Average Climate
EN 12102-2
Sound power level indoor
53 dB(A)
EN 16147
Declared load profile
L
Efficiency ηDHW
135 %
COP
3.23
Heating up time
6:27 h:min
Standby power input
26.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
247 l
Operating test
EN 16147
Temperature operating range
passed
Safety devices checking test
passed
Condensate draining
passed
Domestic Hot Water (DHW)
Warmer Climate
EN 12102-2
Sound power level indoor
53 dB(A)
EN 16147
Declared load profile
L
Efficiency ηDHW
162 %
COP
3.89
Heating up time
5:29 h:min
Standby power input
22.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
247 l
Colder Climate
EN 12102-2
Sound power level indoor
53 dB(A)
EN 16147
Declared load profile
L
Efficiency ηDHW
106 %
COP
2.55
Heating up time
7:44 h:min
Standby power input
30.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
248 l
Average Climate
EN 12102-2
Sound power level indoor
53 dB(A)
EN 16147
Declared load profile
L
Efficiency ηDHW
135 %
COP
3.23
Heating up time
6:27 h:min
Standby power input
26.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
241 l
Operating test
EN 16147
Temperature operating range
passed
Safety devices checking test
passed
Condensate draining
passed