Certificate holders

Subtype

Air Source Heat Pump 018

Certificate Holder
SolarEast Heat Pump Ltd.
No.73 Defu Road
528325 Guangdong Province,
China
Registration number
041-K042-04 / 01
Certification Body
BRE Global Limited
Subtype title
Air Source Heat Pump 018
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

3,500 kg

Certification Date
26.12.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

BLN-018TD1
Configure model
Model name
BLN-018TD1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

18.73 kW

18.52 kW

El input

4.12 kW

6.14 kW

COP

4.55

3.02

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

71 dB(A)

71 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

129 %

Prated

14.04 kW

13.47 kW

SCOP

4.52

3.30

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.42 kW

11.92 kW

COP Tj = -7°C

3.42

2.47

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.64 kW

7.37 kW

COP Tj = +2°C

4.37

3.32

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.49 kW

5.87 kW

COP Tj = +7°C

5.51

3.88

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.29 kW

6.77 kW

COP Tj = 12°C

8.24

5.10

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.42 kW

11.92 kW

COP Tj = Tbiv

3.42

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.29 kW

11.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.11

2.17

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

50 °C

50 °C

Poff

11 W

11 W

PTO

37 W

37 W

PSB

11 W

11 W

PCK

40 W

40 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.76 kW

2.00 kW

Annual energy consumption Qhe

6412 kWh

8435 kWh

BLN-018TB1
Configure model
Model name
BLN-018TB1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

18.73 kW

18.52 kW

El input

4.12 kW

6.14 kW

COP

4.55

3.02

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

71 dB(A)

71 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

129 %

Prated

14.04 kW

13.47 kW

SCOP

4.52

3.30

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.42 kW

11.92 kW

COP Tj = -7°C

3.42

2.47

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.64 kW

7.37 kW

COP Tj = +2°C

4.37

3.32

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.49 kW

5.87 kW

COP Tj = +7°C

5.51

3.88

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.29 kW

6.77 kW

COP Tj = 12°C

8.24

5.10

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.42 kW

11.92 kW

COP Tj = Tbiv

3.42

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.29 kW

11.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.11

2.17

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

50 °C

50 °C

Poff

11 W

11 W

PTO

37 W

37 W

PSB

11 W

11 W

PCK

40 W

40 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.76 kW

2.00 kW

Annual energy consumption Qhe

6412 kWh

8435 kWh

BLN-018TB3
Configure model
Model name
BLN-018TB3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

18.62 kW

18.66 kW

El input

4.05 kW

5.99 kW

COP

4.60

3.12

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

70 dB(A)

71 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

128 %

Prated

13.75 kW

13.73 kW

SCOP

4.53

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.17 kW

12.15 kW

COP Tj = -7°C

3.41

2.52

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.39 kW

7.36 kW

COP Tj = +2°C

4.39

3.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.46 kW

5.86 kW

COP Tj = +7°C

5.62

3.82

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.28 kW

6.83 kW

COP Tj = 12°C

7.99

5.12

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.17 kW

12.15 kW

COP Tj = Tbiv

3.41

2.52

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.39 kW

11.03 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.20

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

50 °C

50 °C

Poff

11 W

11 W

PTO

37 W

37 W

PSB

11 W

11 W

PCK

40 W

40 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.37 kW

2.70 kW

Annual energy consumption Qhe

6271 kWh

8646 kWh

BLN-018TD3
Configure model
Model name
BLN-018TD3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

18.62 kW

18.66 kW

El input

4.05 kW

5.99 kW

COP

4.60

3.12

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

70 dB(A)

71 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

128 %

Prated

13.75 kW

13.73 kW

SCOP

4.53

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.17 kW

12.15 kW

COP Tj = -7°C

3.41

2.52

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.39 kW

7.36 kW

COP Tj = +2°C

4.39

3.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.46 kW

5.86 kW

COP Tj = +7°C

5.62

3.82

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.28 kW

6.83 kW

COP Tj = 12°C

7.99

5.12

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.17 kW

12.15 kW

COP Tj = Tbiv

3.41

2.52

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.39 kW

11.03 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.20

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

50 °C

50 °C

Poff

11 W

11 W

PTO

37 W

37 W

PSB

11 W

11 W

PCK

40 W

40 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.37 kW

2.70 kW

Annual energy consumption Qhe

6271 kWh

8646 kWh