Certificate holders

Subtype

Buderus Logatherm WSW196i.2/186 -16

Certificate Holder
Bosch Thermotechnik GmbH (Buderus)
Sophienstraße 30-32
35576 Wetzlar
Germany
Registration number
011-1W0436
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Buderus Logatherm WSW196i.2/186 -16
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R410A
Mass of Refrigerant

2,300 kg

Certification Date
08.12.2020
Testing basis
HP KEYMARK certification scheme rules rev. 10
Testing laboratory
RISE Research Institutes of Sweden
Generate PDF Export model CSV
  • Number of models 2

Models

WSW196i.2-16 T180 (+W) / 186-16 T180
Configure model
Model name
WSW196i.2-16 T180 (+W) / 186-16 T180
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
No

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

15.54 kW

14.19 kW

El input

4.14 kW

5.68 kW

COP

3.75

2.50

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

155 %

Prated

15.53 kW

14.18 kW

SCOP

5.30

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

15.54 kW

14.19 kW

COP Tj = +2°C

3.75

2.46

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

9.99 kW

9.32 kW

COP Tj = +7°C

5.05

3.63

Cdh Tj = +7 °C

0.990

1.000

Pdh Tj = 12°C

4.89 kW

4.71 kW

COP Tj = 12°C

5.98

4.98

Cdh Tj = +12 °C

0.900

0.990

Pdh Tj = Tbiv

15.54 kW

14.19 kW

COP Tj = Tbiv

3.75

2.46

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.54 kW

14.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.75

2.46

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

71 °C

71 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3916 kWh

4658 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

161 %

Prated

15.53 kW

14.18 kW

SCOP

5.47

4.24

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

10.06 kW

8.96 kW

COP Tj = -7°C

5.18

3.86

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

6.20 kW

5.42 kW

COP Tj = +2°C

5.97

4.74

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.91 kW

4.76 kW

COP Tj = +7°C

6.07

5.09

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

4.88 kW

4.75 kW

COP Tj = 12°C

5.89

5.19

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.53 kW

14.19 kW

COP Tj = Tbiv

3.75

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.54 kW

14.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.75

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

71 °C

71 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6995 kWh

8251 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

154 %

Prated

15.53 kW

14.18 kW

SCOP

5.28

4.06

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.91 kW

12.81 kW

COP Tj = -7°C

4.07

2.81

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.93 kW

7.91 kW

COP Tj = +2°C

5.39

4.21

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.72 kW

5.40 kW

COP Tj = +7°C

6.04

4.72

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

4.89 kW

4.70 kW

COP Tj = 12°C

5.98

4.97

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.54 kW

14.19 kW

COP Tj = Tbiv

3.75

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.54 kW

14.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.75

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

71 °C

71 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6074 kWh

7218 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

127 %

COP

3.05

Heating up time

1:09 h:min

Standby power input

110.0 W

Reference hot water temperature

46.9 °C

Mixed water at 40°C

206 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

127 %

COP

3.05

Heating up time

1:09 h:min

Standby power input

110.0 W

Reference hot water temperature

46.9 °C

Mixed water at 40°C

206 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

127 %

COP

3.05

Heating up time

1:09 h:min

Standby power input

110.0 W

Reference hot water temperature

46.9 °C

Mixed water at 40°C

206 l

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

20.43 kW

17.36 kW

El input

4.32 kW

5.53 kW

COP

4.73

3.14

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

289 %

212 %

Prated

20.43 kW

17.37 kW

SCOP

7.43

5.51

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

18.35 kW

14.99 kW

COP Tj = -7°C

5.21

3.63

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

11.74 kW

9.13 kW

COP Tj = +2°C

7.34

5.58

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.51 kW

6.15 kW

COP Tj = +7°C

9.29

6.85

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.43 kW

6.23 kW

COP Tj = 12°C

9.63

7.21

Cdh Tj = +12 °C

0.980

0.990

Pdh Tj = Tbiv

20.43 kW

17.36 kW

COP Tj = Tbiv

4.73

3.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.43 kW

17.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.73

3.14

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

71 °C

71 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5681 kWh

6511 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

153 %

COP

3.70

Heating up time

0:53 h:min

Standby power input

33.2 W

Reference hot water temperature

46.3 °C

Mixed water at 40°C

201 l

WSW196i.2-16 (+W) / 186-16
Configure model
Model name
WSW196i.2-16 (+W) / 186-16
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

15.54 kW

14.19 kW

El input

4.14 kW

5.68 kW

COP

3.75

2.50

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

155 %

Prated

15.53 kW

14.18 kW

SCOP

5.30

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

15.54 kW

14.19 kW

COP Tj = +2°C

3.75

2.46

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

9.99 kW

9.32 kW

COP Tj = +7°C

5.05

3.63

Cdh Tj = +7 °C

0.990

1.000

Pdh Tj = 12°C

4.89 kW

4.71 kW

COP Tj = 12°C

5.98

4.98

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.54 kW

14.19 kW

COP Tj = Tbiv

3.75

2.46

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.54 kW

14.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.75

2.46

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

71 °C

71 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3916 kWh

4658 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

161 %

Prated

15.53 kW

14.18 kW

SCOP

5.47

4.24

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

10.06 kW

8.96 kW

COP Tj = -7°C

5.18

3.86

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

6.20 kW

5.42 kW

COP Tj = +2°C

5.97

4.74

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.91 kW

4.76 kW

COP Tj = +7°C

6.07

5.09

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

4.88 kW

4.75 kW

COP Tj = 12°C

5.89

5.19

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.53 kW

14.19 kW

COP Tj = Tbiv

3.75

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.54 kW

14.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.75

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

71 °C

71 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6995 kWh

8251 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

154 %

Prated

15.53 kW

14.18 kW

SCOP

5.28

4.06

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.91 kW

12.81 kW

COP Tj = -7°C

4.07

2.81

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.93 kW

7.91 kW

COP Tj = +2°C

5.39

4.21

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.72 kW

5.40 kW

COP Tj = +7°C

6.04

4.72

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

4.89 kW

4.70 kW

COP Tj = 12°C

5.98

4.97

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.54 kW

14.19 kW

COP Tj = Tbiv

3.75

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.54 kW

14.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.75

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

71 °C

71 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6074 kWh

7218 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

20.43 kW

17.36 kW

El input

4.32 kW

5.53 kW

COP

4.73

3.14

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

289 %

212 %

Prated

20.43 kW

17.37 kW

SCOP

7.43

5.51

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

18.35 kW

14.99 kW

COP Tj = -7°C

5.21

3.63

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

11.74 kW

9.13 kW

COP Tj = +2°C

7.34

5.58

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.51 kW

6.15 kW

COP Tj = +7°C

9.29

6.85

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.43 kW

6.23 kW

COP Tj = 12°C

9.63

7.21

Cdh Tj = +12 °C

0.980

0.990

Pdh Tj = Tbiv

20.43 kW

17.36 kW

COP Tj = Tbiv

4.73

3.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.43 kW

17.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.73

3.14

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

71 °C

71 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5681 kWh

6511 kWh