2,300 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
15.54 kW
14.19 kW
El input
4.14 kW
5.68 kW
COP
3.75
2.50
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
204 %
155 %
Prated
15.53 kW
14.18 kW
SCOP
5.30
4.07
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
15.54 kW
14.19 kW
COP Tj = +2°C
3.75
2.46
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
9.99 kW
9.32 kW
COP Tj = +7°C
5.05
3.63
Cdh Tj = +7 °C
0.990
1.000
Pdh Tj = 12°C
4.89 kW
4.71 kW
COP Tj = 12°C
5.98
4.98
Cdh Tj = +12 °C
0.900
0.990
Pdh Tj = Tbiv
15.54 kW
14.19 kW
COP Tj = Tbiv
3.75
2.46
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.54 kW
14.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.75
2.46
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
71 °C
71 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3916 kWh
4658 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
211 %
161 %
Prated
15.53 kW
14.18 kW
SCOP
5.47
4.24
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
10.06 kW
8.96 kW
COP Tj = -7°C
5.18
3.86
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
6.20 kW
5.42 kW
COP Tj = +2°C
5.97
4.74
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
4.91 kW
4.76 kW
COP Tj = +7°C
6.07
5.09
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
4.88 kW
4.75 kW
COP Tj = 12°C
5.89
5.19
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
15.53 kW
14.19 kW
COP Tj = Tbiv
3.75
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.54 kW
14.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.75
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
71 °C
71 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
6995 kWh
8251 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
202 %
154 %
Prated
15.53 kW
14.18 kW
SCOP
5.28
4.06
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.91 kW
12.81 kW
COP Tj = -7°C
4.07
2.81
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
8.93 kW
7.91 kW
COP Tj = +2°C
5.39
4.21
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.72 kW
5.40 kW
COP Tj = +7°C
6.04
4.72
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
4.89 kW
4.70 kW
COP Tj = 12°C
5.98
4.97
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
15.54 kW
14.19 kW
COP Tj = Tbiv
3.75
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.54 kW
14.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.75
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
71 °C
71 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
6074 kWh
7218 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
127 %
COP
3.05
Heating up time
1:09 h:min
Standby power input
110.0 W
Reference hot water temperature
46.9 °C
Mixed water at 40°C
206 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
127 %
COP
3.05
Heating up time
1:09 h:min
Standby power input
110.0 W
Reference hot water temperature
46.9 °C
Mixed water at 40°C
206 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
127 %
COP
3.05
Heating up time
1:09 h:min
Standby power input
110.0 W
Reference hot water temperature
46.9 °C
Mixed water at 40°C
206 l
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
20.43 kW
17.36 kW
El input
4.32 kW
5.53 kW
COP
4.73
3.14
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
289 %
212 %
Prated
20.43 kW
17.37 kW
SCOP
7.43
5.51
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
18.35 kW
14.99 kW
COP Tj = -7°C
5.21
3.63
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
11.74 kW
9.13 kW
COP Tj = +2°C
7.34
5.58
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.51 kW
6.15 kW
COP Tj = +7°C
9.29
6.85
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.43 kW
6.23 kW
COP Tj = 12°C
9.63
7.21
Cdh Tj = +12 °C
0.980
0.990
Pdh Tj = Tbiv
20.43 kW
17.36 kW
COP Tj = Tbiv
4.73
3.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
20.43 kW
17.36 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.73
3.14
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
71 °C
71 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5681 kWh
6511 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
153 %
COP
3.70
Heating up time
0:53 h:min
Standby power input
33.2 W
Reference hot water temperature
46.3 °C
Mixed water at 40°C
201 l
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
15.54 kW
14.19 kW
El input
4.14 kW
5.68 kW
COP
3.75
2.50
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
204 %
155 %
Prated
15.53 kW
14.18 kW
SCOP
5.30
4.07
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
15.54 kW
14.19 kW
COP Tj = +2°C
3.75
2.46
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
9.99 kW
9.32 kW
COP Tj = +7°C
5.05
3.63
Cdh Tj = +7 °C
0.990
1.000
Pdh Tj = 12°C
4.89 kW
4.71 kW
COP Tj = 12°C
5.98
4.98
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
15.54 kW
14.19 kW
COP Tj = Tbiv
3.75
2.46
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.54 kW
14.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.75
2.46
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
71 °C
71 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3916 kWh
4658 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
211 %
161 %
Prated
15.53 kW
14.18 kW
SCOP
5.47
4.24
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
10.06 kW
8.96 kW
COP Tj = -7°C
5.18
3.86
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
6.20 kW
5.42 kW
COP Tj = +2°C
5.97
4.74
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
4.91 kW
4.76 kW
COP Tj = +7°C
6.07
5.09
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
4.88 kW
4.75 kW
COP Tj = 12°C
5.89
5.19
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
15.53 kW
14.19 kW
COP Tj = Tbiv
3.75
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.54 kW
14.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.75
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
71 °C
71 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
6995 kWh
8251 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
203 %
154 %
Prated
15.53 kW
14.18 kW
SCOP
5.28
4.06
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.91 kW
12.81 kW
COP Tj = -7°C
4.07
2.81
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
8.93 kW
7.91 kW
COP Tj = +2°C
5.39
4.21
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.72 kW
5.40 kW
COP Tj = +7°C
6.04
4.72
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
4.89 kW
4.70 kW
COP Tj = 12°C
5.98
4.97
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
15.54 kW
14.19 kW
COP Tj = Tbiv
3.75
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.54 kW
14.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.75
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
71 °C
71 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
6074 kWh
7218 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
20.43 kW
17.36 kW
El input
4.32 kW
5.53 kW
COP
4.73
3.14
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
289 %
212 %
Prated
20.43 kW
17.37 kW
SCOP
7.43
5.51
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
18.35 kW
14.99 kW
COP Tj = -7°C
5.21
3.63
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
11.74 kW
9.13 kW
COP Tj = +2°C
7.34
5.58
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.51 kW
6.15 kW
COP Tj = +7°C
9.29
6.85
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.43 kW
6.23 kW
COP Tj = 12°C
9.63
7.21
Cdh Tj = +12 °C
0.980
0.990
Pdh Tj = Tbiv
20.43 kW
17.36 kW
COP Tj = Tbiv
4.73
3.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
20.43 kW
17.36 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.73
3.14
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
71 °C
71 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5681 kWh
6511 kWh