Certificate holders

Subtype

Bosch Compress 7800i LW 6 and 8

Certificate Holder
Bosch Thermotechnik GmbH
Junkersstraße 20 - 24
73249 Wernau
Germany
Registration number
011-1W0431
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Bosch Compress 7800i LW 6 and 8
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R410A
Mass of Refrigerant

1,350 kg

Certification Date
08.12.2020
Testing basis
HP KEYMARK certification scheme rules rev. 10
Generate PDF Export model CSV
  • Number of models 4

Models

CS7800i LW 6 M (+MF)
Configure model
Model name
CS7800i LW 6 M (+MF)
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
No

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.85 kW

5.24 kW

El input

1.35 kW

1.91 kW

COP

4.33

2.75

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

141 %

Prated

5.85 kW

5.24 kW

SCOP

5.21

3.73

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.85 kW

5.24 kW

COP Tj = +2°C

4.33

2.75

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.98 kW

3.63 kW

COP Tj = +7°C

5.14

3.47

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

2.12 kW

1.97 kW

COP Tj = 12°C

5.90

4.46

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

5.85 kW

5.24 kW

COP Tj = Tbiv

4.33

2.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.85 kW

5.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.33

2.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1500 kWh

1876 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

151 %

Prated

5.85 kW

5.24 kW

SCOP

5.44

3.99

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.62 kW

3.29 kW

COP Tj = -7°C

5.29

3.71

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.34 kW

1.94 kW

COP Tj = +2°C

5.85

4.37

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

2.13 kW

1.98 kW

COP Tj = +7°C

5.86

4.69

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

2.11 kW

2.00 kW

COP Tj = 12°C

5.78

4.78

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

5.85 kW

5.24 kW

COP Tj = Tbiv

4.33

2.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.85 kW

5.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.33

2.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2650 kWh

3241 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

145 %

Prated

5.85 kW

5.24 kW

SCOP

5.26

3.82

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.13 kW

4.58 kW

COP Tj = -7°C

4.53

2.97

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.34 kW

3.04 kW

COP Tj = +2°C

5.39

3.87

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.12 kW

1.97 kW

COP Tj = +7°C

5.87

4.52

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

2.12 kW

1.97 kW

COP Tj = 12°C

5.91

4.57

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

5.85 kW

5.24 kW

COP Tj = Tbiv

4.33

2.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.84 kW

5.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.33

2.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2298 kWh

2835 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

126 %

COP

3.06

Heating up time

1:35 h:min

Standby power input

30.9 W

Reference hot water temperature

47.6 °C

Mixed water at 40°C

211 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

126 %

COP

3.06

Heating up time

1:35 h:min

Standby power input

30.9 W

Reference hot water temperature

47.6 °C

Mixed water at 40°C

211 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

126 %

COP

3.06

Heating up time

1:35 h:min

Standby power input

30.9 W

Reference hot water temperature

47.6 °C

Mixed water at 40°C

211 l

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.80 kW

6.89 kW

El input

1.38 kW

2.03 kW

COP

5.66

3.40

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

300 %

202 %

Prated

7.80 kW

6.89 kW

SCOP

7.70

5.24

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.94 kW

6.22 kW

COP Tj = -7°C

6.07

3.78

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.34 kW

3.64 kW

COP Tj = +2°C

7.77

5.29

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.80 kW

2.61 kW

COP Tj = +7°C

9.40

6.44

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.80 kW

2.65 kW

COP Tj = 12°C

9.35

6.74

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

7.80 kW

6.89 kW

COP Tj = Tbiv

5.66

3.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

6.89 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.66

3.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2092 kWh

2721 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

xl

Efficiency ηDHW

126 %

COP

3.06

Heating up time

1:35 h:min

Standby power input

30.9 W

Reference hot water temperature

47.6 °C

Mixed water at 40°C

211 l

CS7800i LW 6 (+F)
Configure model
Model name
CS7800i LW 6 (+F)
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.85 kW

5.24 kW

El input

1.35 kW

1.91 kW

COP

4.33

2.75

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

141 %

Prated

5.85 kW

5.24 kW

SCOP

5.21

3.73

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.85 kW

5.24 kW

COP Tj = +2°C

4.33

2.75

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.98 kW

3.63 kW

COP Tj = +7°C

5.14

3.47

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

2.12 kW

1.97 kW

COP Tj = 12°C

5.90

4.46

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

5.85 kW

5.24 kW

COP Tj = Tbiv

4.33

2.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.85 kW

5.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.33

2.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1500 kWh

1876 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

151 %

Prated

5.85 kW

5.24 kW

SCOP

5.44

3.99

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.62 kW

3.29 kW

COP Tj = -7°C

5.29

3.71

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

2.34 kW

1.94 kW

COP Tj = +2°C

5.85

4.37

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

2.13 kW

1.98 kW

COP Tj = +7°C

5.86

4.69

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

2.11 kW

2.00 kW

COP Tj = 12°C

5.78

4.78

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

5.85 kW

5.24 kW

COP Tj = Tbiv

4.33

2.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.85 kW

5.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.33

2.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2650 kWh

3241 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

145 %

Prated

5.85 kW

5.24 kW

SCOP

5.26

3.82

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.13 kW

4.85 kW

COP Tj = -7°C

4.53

2.97

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.34 kW

3.04 kW

COP Tj = +2°C

5.39

3.87

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.12 kW

1.97 kW

COP Tj = +7°C

5.87

4.52

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

2.12 kW

1.97 kW

COP Tj = 12°C

5.91

4.57

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

5.85 kW

5.24 kW

COP Tj = Tbiv

4.33

2.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.85 kW

5.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.33

2.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2298 kWh

2835 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.80 kW

6.89 kW

El input

1.38 kW

2.03 kW

COP

5.66

3.40

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

300 %

202 %

Prated

7.80 kW

6.89 kW

SCOP

7.70

5.24

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.94 kW

6.22 kW

COP Tj = -7°C

6.07

3.78

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.34 kW

3.64 kW

COP Tj = +2°C

7.77

5.29

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.80 kW

2.61 kW

COP Tj = +7°C

9.24

6.44

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.80 kW

2.65 kW

COP Tj = 12°C

9.35

6.74

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

7.80 kW

6.89 kW

COP Tj = Tbiv

5.66

3.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

6.89 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.66

3.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2092 kWh

2721 kWh

CS7800i LW 8 M (+MF)
Configure model
Model name
CS7800i LW 8 M (+MF)
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
No

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.63 kW

6.74 kW

El input

1.87 kW

2.57 kW

COP

4.08

2.62

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

144 %

Prated

7.62 kW

6.74 kW

SCOP

5.26

3.80

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.62 kW

6.74 kW

COP Tj = +2°C

4.08

2.62

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

5.23 kW

4.15 kW

COP Tj = +7°C

5.07

3.58

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

2.67 kW

2.00 kW

COP Tj = 12°C

6.02

4.89

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

7.62 kW

6.74 kW

COP Tj = Tbiv

4.08

2.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.62 kW

6.74 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.08

2.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1935 kWh

2369 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

214 %

157 %

Prated

7.62 kW

6.74 kW

SCOP

5.56

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.59 kW

4.22 kW

COP Tj = -7°C

5.35

3.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.01 kW

2.51 kW

COP Tj = +2°C

6.00

4.58

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.14 kW

2.02 kW

COP Tj = +7°C

6.21

5.06

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

2.11 kW

2.02 kW

COP Tj = 12°C

5.95

5.06

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

7.62 kW

6.74 kW

COP Tj = Tbiv

4.08

2.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.62 kW

6.74 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.08

2.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3381 kWh

4024 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

150 %

Prated

7.63 kW

6.74 kW

SCOP

5.28

3.95

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.06 kW

5.86 kW

COP Tj = -7°C

4.29

2.94

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.24 kW

3.76 kW

COP Tj = +2°C

5.37

4.01

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.67 kW

2.53 kW

COP Tj = +7°C

6.00

4.70

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.11 kW

1.99 kW

COP Tj = 12°C

6.12

4.86

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

7.63 kW

6.74 kW

COP Tj = Tbiv

4.08

2.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.62 kW

6.74 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.08

2.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2984 kWh

3530 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

124 %

COP

3.01

Heating up time

1:31 h:min

Standby power input

87.0 W

Reference hot water temperature

47.6 °C

Mixed water at 40°C

211 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

124 %

COP

3.01

Heating up time

1:31 h:min

Standby power input

87.0 W

Reference hot water temperature

47.6 °C

Mixed water at 40°C

211 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

124 %

COP

3.01

Heating up time

1:31 h:min

Standby power input

87.0 W

Reference hot water temperature

47.6 °C

Mixed water at 40°C

211 l

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.03 kW

9.09 kW

El input

1.99 kW

2.87 kW

COP

5.04

3.17

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

288 %

201 %

Prated

9.09 kW

9.09 kW

SCOP

7.40

5.23

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.31 kW

7.85 kW

COP Tj = -7°C

5.37

3.60

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.50 kW

4.98 kW

COP Tj = +2°C

7.38

5.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.53 kW

3.36 kW

COP Tj = +7°C

9.18

6.53

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.80 kW

2.65 kW

COP Tj = 12°C

9.60

7.00

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

10.03 kW

9.09 kW

COP Tj = Tbiv

5.04

3.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.03 kW

9.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.04

3.17

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2800 kWh

3591 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

148 %

COP

3.59

Heating up time

1:11 h:min

Standby power input

30.3 W

Reference hot water temperature

47.1 °C

Mixed water at 40°C

204 l

CS7800i LW 8 (+F)
Configure model
Model name
CS7800i LW 8 (+F)
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.63 kW

6.74 kW

El input

1.87 kW

2.57 kW

COP

4.08

2.62

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

144 %

Prated

7.62 kW

6.74 kW

SCOP

5.26

3.80

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.62 kW

6.74 kW

COP Tj = +2°C

4.08

2.62

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

5.23 kW

4.15 kW

COP Tj = +7°C

5.07

3.58

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

2.67 kW

2.00 kW

COP Tj = 12°C

6.02

4.89

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

7.62 kW

6.74 kW

COP Tj = Tbiv

4.08

2.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.62 kW

6.74 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.08

2.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1935 kWh

2369 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

214 %

157 %

Prated

7.62 kW

6.74 kW

SCOP

5.56

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.59 kW

4.22 kW

COP Tj = -7°C

5.35

3.77

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.01 kW

2.51 kW

COP Tj = +2°C

6.00

4.58

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.14 kW

2.02 kW

COP Tj = +7°C

6.21

5.06

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

2.11 kW

2.02 kW

COP Tj = 12°C

5.95

5.06

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

7.62 kW

6.74 kW

COP Tj = Tbiv

4.08

2.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.62 kW

6.74 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.08

2.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3381 kWh

4024 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

150 %

Prated

7.63 kW

6.74 kW

SCOP

5.28

3.95

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.06 kW

5.86 kW

COP Tj = -7°C

4.29

2.94

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.24 kW

3.76 kW

COP Tj = +2°C

5.37

4.01

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.67 kW

2.53 kW

COP Tj = +7°C

6.00

4.70

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.11 kW

1.99 kW

COP Tj = 12°C

6.12

4.86

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

7.63 kW

6.74 kW

COP Tj = Tbiv

4.08

2.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.62 kW

6.74 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.08

2.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2984 kWh

3530 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.03 kW

9.09 kW

El input

1.99 kW

2.87 kW

COP

5.04

3.17

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

288 %

201 %

Prated

9.09 kW

9.09 kW

SCOP

7.40

5.23

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.31 kW

7.85 kW

COP Tj = -7°C

5.37

3.60

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.50 kW

4.98 kW

COP Tj = +2°C

7.38

5.25

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.53 kW

3.36 kW

COP Tj = +7°C

9.18

6.53

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.80 kW

2.65 kW

COP Tj = 12°C

9.60

7.00

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

10.03 kW

9.09 kW

COP Tj = Tbiv

5.04

3.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.03 kW

9.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.04

3.17

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

67 °C

67 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2800 kWh

3591 kWh