1,250 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.21 kW
10.14 kW
El input
1.95 kW
3.74 kW
COP
4.72
2.71
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
128 %
Prated
6.99 kW
7.25 kW
SCOP
4.51
3.28
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.19 kW
6.41 kW
COP Tj = -7°C
3.10
1.99
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.81 kW
3.90 kW
COP Tj = +2°C
4.77
3.39
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.90 kW
3.37 kW
COP Tj = +7°C
5.50
4.25
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.08 kW
4.09 kW
COP Tj = 12°C
7.02
6.55
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.19 kW
6.41 kW
COP Tj = Tbiv
3.10
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.42 kW
3.78 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.45
1.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
6 W
6 W
PTO
13 W
13 W
PSB
6 W
6 W
PCK
26 W
26 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.58 kW
3.47 kW
Annual energy consumption Qhe
3203 kWh
4563 kWh