2,350 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
19.40 kW
16.90 kW
El input
4.52 kW
6.11 kW
COP
4.29
2.77
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
70 dB(A)
71 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
130 %
Prated
12.87 kW
11.83 kW
SCOP
4.50
3.32
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.38 kW
10.47 kW
COP Tj = -7°C
3.41
2.25
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.18 kW
6.42 kW
COP Tj = +2°C
4.34
3.29
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.29 kW
6.95 kW
COP Tj = +7°C
5.73
4.18
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.63 kW
7.97 kW
COP Tj = 12°C
7.83
6.89
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.38 kW
10.47 kW
COP Tj = Tbiv
3.41
2.25
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.79 kW
11.77 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.85
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
5 W
5 W
PTO
16 W
16 W
PSB
5 W
5 W
PCK
24 W
24 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.08 kW
0.06 kW
Annual energy consumption Qhe
5908 kWh
7372 kWh