Certificate holders

Subtype

Air to Water Heat Pump 200

Certificate Holder
Guangdong New Energy Technology Development Co., Ltd.
NO.125, Chuangyou Road
511340 Guangdong
China
Registration number
041-K054-03
Certification Body
BRE Global Limited
Subtype title
Air to Water Heat Pump 200
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,350 kg

Certification Date
16.05.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

NE-F200HCR4TINVM
Configure model
Model name
NE-F200HCR4TINVM
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

19.40 kW

16.90 kW

El input

4.52 kW

6.11 kW

COP

4.29

2.77

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

70 dB(A)

71 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

130 %

Prated

12.87 kW

11.83 kW

SCOP

4.50

3.32

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.38 kW

10.47 kW

COP Tj = -7°C

3.41

2.25

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.18 kW

6.42 kW

COP Tj = +2°C

4.34

3.29

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.29 kW

6.95 kW

COP Tj = +7°C

5.73

4.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.63 kW

7.97 kW

COP Tj = 12°C

7.83

6.89

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.38 kW

10.47 kW

COP Tj = Tbiv

3.41

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.79 kW

11.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.69

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

5 W

5 W

PTO

16 W

16 W

PSB

5 W

5 W

PCK

24 W

24 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

0.06 kW

Annual energy consumption Qhe

5908 kWh

7372 kWh