Certificate holders

Subtype

THERMOR Aérolia 11

Certificate Holder
Groupe Atlantic
44 boulevard des Etats-Unis
85000 La Roche Sur Yon
France
Registration number
012-C700156
Certification Body
RISE CERT
Subtype title
THERMOR Aérolia 11
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,500 kg

Certification Date
09.12.2022
Testing basis
EN 14511:2013, EN 16147:2011, EN 14825:2013, EN 12102:2013
Phase-out Date
16.04.2026
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

THERMOR Aérolia 11 Phasing out on 16.04.2026
Configure model
Model name
THERMOR Aérolia 11
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
16.04.2026

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.80 kW

7.59 kW

El input

2.54 kW

3.07 kW

COP

4.25

2.47

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

151 %

112 %

Prated

11.30 kW

9.30 kW

SCOP

3.85

2.87

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.00 kW

8.20 kW

COP Tj = -7°C

2.60

1.90

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.10 kW

5.00 kW

COP Tj = +2°C

3.70

2.80

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.20 kW

5.90 kW

COP Tj = +7°C

5.30

3.80

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.40 kW

7.00 kW

COP Tj = 12°C

6.90

4.80

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.00 kW

8.20 kW

COP Tj = Tbiv

2.60

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.00 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

1.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

8 W

8 W

PTO

45 W

22 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.30 kW

1.30 kW

Annual energy consumption Qhe

6062 kWh

6623 kWh

THERMOR Aérolia Duo 11 Phasing out on 16.04.2026
Configure model
Model name
THERMOR Aérolia Duo 11
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
16.04.2026

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.80 kW

7.59 kW

El input

2.54 kW

3.07 kW

COP

4.25

2.47

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

151 %

112 %

Prated

11.30 kW

9.30 kW

SCOP

3.85

2.87

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.00 kW

8.20 kW

COP Tj = -7°C

2.60

1.90

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.10 kW

5.00 kW

COP Tj = +2°C

3.70

2.80

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.20 kW

5.90 kW

COP Tj = +7°C

5.30

3.80

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.40 kW

7.00 kW

COP Tj = 12°C

6.90

4.80

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.00 kW

8.20 kW

COP Tj = Tbiv

2.60

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.00 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

1.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

8 W

8 W

PTO

45 W

22 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.30 kW

1.30 kW

Annual energy consumption Qhe

6062 kWh

6623 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

88 %

COP

2.25

Heating up time

0:46 h:min

Standby power input

40.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

250 l