Certificate holders

Subtype

DAIKIN ALTHERMA 3 R F 3.5KW

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0198
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA 3 R F 3.5KW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,000 kg

Certification Date
27.03.2020
Testing basis
European KEYMARK Scheme for Heat Pumps Rev.10
Generate PDF Export model CSV
  • Number of models 4

Models

ERLA03DV / EHFH03S18D3V
Configure model
Model name
ERLA03DV / EHFH03S18D3V
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.59 kW

3.53 kW

El input

0.72 kW

1.21 kW

COP

5

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

Cooling capacity

4

EER

3.6

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173 %

126 %

Prated

3.5 kW

3.5 kW

SCOP

4.4

3.2

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.3 kW

3.2 kW

COP Tj = -7°C

3.03

2.21

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

2 kW

1.9 kW

COP Tj = +2°C

4.47

3.28

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

1.4 kW

1.2 kW

COP Tj = +7°C

6.18

4.16

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

8.3

6.26

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

3.6 kW

3.5 kW

COP Tj = Tbiv

2.72

1.76

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.6 kW

3.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.76

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

22 W

22 W

PSB

11 W

11 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

1643 kWh

2237 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.67

Heating up time

1:40 h:min

Standby power input

19 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

240 l

ERLA03DV / EHFH03S18D3V + cooling kit
Configure model
Model name
ERLA03DV / EHFH03S18D3V + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.59 kW

3.53 kW

El input

0.72 kW

1.21 kW

COP

5

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.17 kW

Cooling capacity

3.49

EER

3.03

EN 14825

+7°C/+12°C

Pdesignc

3.5 kW

SEER

4.41

Pdc Tj = 35°C

3.49 kW

EER Tj = 35°C

3.03

Pdc Tj = 30°C

2.66 kW

EER Tj = 30°C

4.21

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

1.73 kW

EER Tj = 25°C

5.11

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

1.38 kW

EER Tj = 20°C

6.79

Cdc Tj = 20 °C

1

Poff

11 W

PTO

22 W

PSB

11 W

PCK

11 W

Annual energy consumption Qce

476 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173 %

126 %

Prated

3.5 kW

3.5 kW

SCOP

4.4

3.2

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.3 kW

3.2 kW

COP Tj = -7°C

3.03

2.21

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

2 kW

1.9 kW

COP Tj = +2°C

4.47

3.28

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

1.4 kW

1.2 kW

COP Tj = +7°C

6.18

4.16

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

8.3

6.26

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

3.6 kW

3.5 kW

COP Tj = Tbiv

2.72

1.76

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.6 kW

3.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.76

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

22 W

22 W

PSB

11 W

11 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

1643 kWh

2237 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.67

Heating up time

1:40 h:min

Standby power input

19 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

240 l

ERLA03DV / EHFZ03S18D3V
Configure model
Model name
ERLA03DV / EHFZ03S18D3V
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.59 kW

3.53 kW

El input

0.72 kW

1.21 kW

COP

5

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

Cooling capacity

4

EER

3.6

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173 %

126 %

Prated

3.5 kW

3.5 kW

SCOP

4.4

3.2

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.3 kW

3.2 kW

COP Tj = -7°C

3.03

2.21

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

2 kW

1.9 kW

COP Tj = +2°C

4.47

3.28

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

1.4 kW

1.2 kW

COP Tj = +7°C

6.18

4.16

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

8.3

6.26

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

3.6 kW

3.5 kW

COP Tj = Tbiv

2.72

1.76

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.6 kW

3.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.76

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

22 W

22 W

PSB

11 W

11 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

1643 kWh

2237 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.67

Heating up time

1:40 h:min

Standby power input

19 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

240 l

ERLA03DV / EHFZ03S18D3V + cooling kit
Configure model
Model name
ERLA03DV / EHFZ03S18D3V + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.59 kW

3.53 kW

El input

0.72 kW

1.21 kW

COP

5

2.94

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.17 kW

Cooling capacity

3.49

EER

3.03

EN 14825

+7°C/+12°C

Pdesignc

3.5 kW

SEER

4.41

Pdc Tj = 35°C

3.49 kW

EER Tj = 35°C

3.03

Pdc Tj = 30°C

2.66 kW

EER Tj = 30°C

4.21

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

1.73 kW

EER Tj = 25°C

5.11

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

1.38 kW

EER Tj = 20°C

6.79

Cdc Tj = 20 °C

1

Poff

11 W

PTO

22 W

PSB

11 W

PCK

11 W

Annual energy consumption Qce

476 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173 %

126 %

Prated

3.5 kW

3.5 kW

SCOP

4.4

3.2

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.3 kW

3.2 kW

COP Tj = -7°C

3.03

2.21

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

2 kW

1.9 kW

COP Tj = +2°C

4.47

3.28

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

1.4 kW

1.2 kW

COP Tj = +7°C

6.18

4.16

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

1.7 kW

1.6 kW

COP Tj = 12°C

8.3

6.26

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

3.6 kW

3.5 kW

COP Tj = Tbiv

2.72

1.76

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.6 kW

3.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.76

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

22 W

22 W

PSB

11 W

11 W

PCK

11 W

11 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

1643 kWh

2237 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.67

Heating up time

1:40 h:min

Standby power input

19 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

240 l