Certificate holders

Subtype

Buderus Logatherm WPS 10-1

Certificate Holder
Bosch Thermotechnik GmbH (Buderus)
Sophienstraße 30-32
35576 Wetzlar
Germany
Registration number
011-1W0182
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Buderus Logatherm WPS 10-1
Driving energy
n/a
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

2,400 kg

Certification Date
17.11.2017
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 1

Models

Buderus Logatherm WPS 10-1
Configure model
Model name
Buderus Logatherm WPS 10-1
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.08 kW

9.37 kW

El input

2.18 kW

3.2 kW

COP

4.63

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

141 %

Prated

11 kW

11 kW

SCOP

4.97

3.72

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.1 kW

9.46 kW

COP Tj = -7°C

4.72

3.14

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

10.17 kW

9.69 kW

COP Tj = +2°C

4.96

3.71

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

10.24 kW

9.84 kW

COP Tj = +7°C

5.21

4.11

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

10.31 kW

9.98 kW

COP Tj = 12°C

5.49

4.55

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

10.1 kW

9.5 kW

COP Tj = Tbiv

4.72

3.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.08 kW

9.37 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.63

2.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

62 °C

62 °C

Poff

6 W

6 W

PTO

6 W

6 W

PSB

6 W

6 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.92 kW

1.63 kW

Annual energy consumption Qhe

4570 kWh

6110 kWh