Certificate holders

Subtype

Buderus Logatherm WPS 10K-1

Certificate Holder
Bosch Thermotechnik GmbH (Buderus)
Sophienstraße 30-32
35576 Wetzlar
Germany
Registration number
011-1W0179
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Buderus Logatherm WPS 10K-1
Driving energy
n/a
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

2,200 kg

Certification Date
17.11.2017
Testing basis
HP KEYMARK certification scheme rules rev. 14
Testing laboratory
Universität Stuttgart, Prüfstelle HLK am Institut für Gebäudeenergetik, Thermotechnik und Energiespeicherung (IGTE), DE
Generate PDF Export model CSV
  • Number of models 1

Models

Buderus Logatherm WPS 10K-1
Configure model
Model name
Buderus Logatherm WPS 10K-1
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
No

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.87 kW

9.15 kW

El input

2.27 kW

3.26 kW

COP

4.34

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

133 %

Prated

11 kW

11 kW

SCOP

4.73

3.51

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.9 kW

9.24 kW

COP Tj = -7°C

4.46

2.98

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

9.96 kW

9.45 kW

COP Tj = +2°C

4.72

3.49

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

10.01 kW

9.58 kW

COP Tj = +7°C

4.97

3.89

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

10.07 kW

9.72 kW

COP Tj = 12°C

5.23

4.35

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

9.9 kW

9.29 kW

COP Tj = Tbiv

4.46

3.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.87 kW

9.15 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.34

2.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

62 °C

62 °C

Poff

6 W

6 W

PTO

6 W

6 W

PSB

6 W

6 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.13 kW

1.85 kW

Annual energy consumption Qhe

4809 kWh

6469 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

83 %

COP

2.03

Heating up time

1:02 h:min

Standby power input

25.4 W

Reference hot water temperature

44.6 °C

Mixed water at 40°C

179 l