Certificate holders

Subtype

NIMBUS 110 S - ARIANEXT 110 S - AEROTOP SPLIT 11

Certificate Holder
Ariston Thermo Group
Viale Aristide Merloni 45
I-60044 Fabriano (AN)
Italy
Registration number
ICIM-PDC-000001 / 03
Certification Body
ICIM S.p.A.
Subtype title
NIMBUS 110 S - ARIANEXT 110 S - AEROTOP SPLIT 11
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

4,300 kg

Certification Date
19.12.2017
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 28

Models

AEROTOP SPLIT 11M-R
Configure model
Model name
AEROTOP SPLIT 11M-R
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

ARIANEXT PLUS 110 S-T LINK
Configure model
Model name
ARIANEXT PLUS 110 S-T LINK
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

ARIANEXT PLUS 110 S-T
Configure model
Model name
ARIANEXT PLUS 110 S-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

NIMBUS PLUS 110 S-T NET
Configure model
Model name
NIMBUS PLUS 110 S-T NET
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

AEROTOP SPLIT 11M-CR
Configure model
Model name
AEROTOP SPLIT 11M-CR
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.70

Heating up time

01:16 h:min

Standby power input

39.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

248 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.15

Heating up time

01:49 h:min

Standby power input

57.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

250 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.56

Heating up time

01:28 h:min

Standby power input

52.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

251 l

ARIANEXT COMPACT 110 S-T LINK
Configure model
Model name
ARIANEXT COMPACT 110 S-T LINK
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.70

Heating up time

01:16 h:min

Standby power input

39.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

248 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.15

Heating up time

01:49 h:min

Standby power input

57.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

250 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.56

Heating up time

01:28 h:min

Standby power input

52.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

251 l

ARIANEXT FLEX 110 S-T LINK
Configure model
Model name
ARIANEXT FLEX 110 S-T LINK
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.70

Heating up time

01:16 h:min

Standby power input

39.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

248 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.15

Heating up time

01:49 h:min

Standby power input

57.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

250 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.56

Heating up time

01:28 h:min

Standby power input

52.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

251 l

ARIANEXT FLEX 110 S-T - 300 LINK
Configure model
Model name
ARIANEXT FLEX 110 S-T - 300 LINK
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

132 %

COP

3.30

Heating up time

01:34 h:min

Standby power input

48.0 W

Reference hot water temperature

54.2 °C

Mixed water at 40°C

430 l

Colder Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

97 %

COP

2.43

Heating up time

02:15 h:min

Standby power input

63.0 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

422 l

Average Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

122 %

COP

3.06

Heating up time

01:52 h:min

Standby power input

53.0 W

Reference hot water temperature

54.5 °C

Mixed water at 40°C

434 l

NIMBUS COMPACT 110 S-T NET
Configure model
Model name
NIMBUS COMPACT 110 S-T NET
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.70

Heating up time

01:16 h:min

Standby power input

39.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

248 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.15

Heating up time

01:49 h:min

Standby power input

57.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

250 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.56

Heating up time

01:28 h:min

Standby power input

52.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

251 l

NIMBUS FLEX 110 S-T NET
Configure model
Model name
NIMBUS FLEX 110 S-T NET
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.70

Heating up time

01:16 h:min

Standby power input

39.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

248 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.15

Heating up time

01:49 h:min

Standby power input

57.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

250 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.56

Heating up time

01:28 h:min

Standby power input

52.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

251 l

NIMBUS FLEX 110 S-T - 300 NET
Configure model
Model name
NIMBUS FLEX 110 S-T - 300 NET
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

132 %

COP

3.30

Heating up time

01:34 h:min

Standby power input

48.0 W

Reference hot water temperature

54.2 °C

Mixed water at 40°C

430 l

Colder Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

97 %

COP

2.43

Heating up time

02:15 h:min

Standby power input

63.0 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

422 l

Average Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

122 %

COP

3.06

Heating up time

01:52 h:min

Standby power input

53.0 W

Reference hot water temperature

54.5 °C

Mixed water at 40°C

434 l

ARIANEXT COMPACT 110 S-T
Configure model
Model name
ARIANEXT COMPACT 110 S-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

127 %

COP

3.01

Heating up time

00:47 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

247 l

ARIANEXT FLEX 110 S-T
Configure model
Model name
ARIANEXT FLEX 110 S-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

127 %

COP

3.01

Heating up time

00:47 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

247 l

ARIANEXT FLEX 110 S-T - 300
Configure model
Model name
ARIANEXT FLEX 110 S-T - 300
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:52 h:min

Standby power input

61.0 W

Reference hot water temperature

54.4 °C

Mixed water at 40°C

434 l

AEROTOP SPLIT 11M-RX
Configure model
Model name
AEROTOP SPLIT 11M-RX
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

ARIANEXT PLUS 110 S LINK
Configure model
Model name
ARIANEXT PLUS 110 S LINK
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

ARIANEXT PLUS 110 S
Configure model
Model name
ARIANEXT PLUS 110 S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

NIMBUS PLUS 110 S NET
Configure model
Model name
NIMBUS PLUS 110 S NET
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

AEROTOP SPLIT 11M-CRX
Configure model
Model name
AEROTOP SPLIT 11M-CRX
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.70

Heating up time

01:16 h:min

Standby power input

39.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

248 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.15

Heating up time

01:49 h:min

Standby power input

57.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

250 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.56

Heating up time

01:28 h:min

Standby power input

52.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

251 l

ARIANEXT COMPACT 110 S LINK
Configure model
Model name
ARIANEXT COMPACT 110 S LINK
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.70

Heating up time

01:16 h:min

Standby power input

39.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

248 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.15

Heating up time

01:49 h:min

Standby power input

57.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

250 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.56

Heating up time

01:28 h:min

Standby power input

52.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

251 l

ARIANEXT FLEX 110 S LINK
Configure model
Model name
ARIANEXT FLEX 110 S LINK
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.70

Heating up time

01:16 h:min

Standby power input

39.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

248 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.15

Heating up time

01:49 h:min

Standby power input

57.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

250 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.56

Heating up time

01:28 h:min

Standby power input

52.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

251 l

ARIANEXT FLEX 110 S - 300 LINK
Configure model
Model name
ARIANEXT FLEX 110 S - 300 LINK
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

132 %

COP

3.30

Heating up time

01:34 h:min

Standby power input

48.0 W

Reference hot water temperature

54.2 °C

Mixed water at 40°C

430 l

Colder Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

97 %

COP

2.43

Heating up time

02:15 h:min

Standby power input

63.0 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

422 l

Average Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

122 %

COP

3.06

Heating up time

01:52 h:min

Standby power input

53.0 W

Reference hot water temperature

54.5 °C

Mixed water at 40°C

434 l

NIMBUS COMPACT 110 S NET
Configure model
Model name
NIMBUS COMPACT 110 S NET
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.70

Heating up time

01:16 h:min

Standby power input

39.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

248 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.15

Heating up time

01:49 h:min

Standby power input

57.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

250 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.56

Heating up time

01:28 h:min

Standby power input

52.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

251 l

NIMBUS FLEX 110 S NET
Configure model
Model name
NIMBUS FLEX 110 S NET
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

111 %

COP

2.70

Heating up time

01:16 h:min

Standby power input

39.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

248 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.15

Heating up time

01:49 h:min

Standby power input

57.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

250 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.56

Heating up time

01:28 h:min

Standby power input

52.0 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

251 l

NIMBUS FLEX 110 S - 300 NET
Configure model
Model name
NIMBUS FLEX 110 S - 300 NET
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

8.21 kW

7.46 kW

ηs

250 %

161 %

Prated

8.21 kW

7.46 kW

SCOP

6.33

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.21 kW

7.46 kW

COP Tj = +2°C

4.28

2.50

Pdh Tj = +7°C

5.36 kW

4.90 kW

COP Tj = +7°C

5.51

3.34

Pdh Tj = 12°C

4.39 kW

4.14 kW

COP Tj = 12°C

8.35

5.86

Pdh Tj = Tbiv

8.21 kW

7.46 kW

COP Tj = Tbiv

4.28

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.21 kW

7.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.28

2.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1734 kWh

2436 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.91 kW

17.01 kW

ηs

149 %

112 %

Prated

17.91 kW

17.01 kW

SCOP

3.80

2.87

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.84 kW

10.30 kW

COP Tj = -7°C

3.45

2.71

Pdh Tj = +2°C

6.59 kW

6.21 kW

COP Tj = +2°C

4.91

3.76

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

6.56

5.04

Pdh Tj = 12°C

4.42 kW

4.28 kW

COP Tj = 12°C

9.15

7.64

Pdh Tj = Tbiv

10.84 kW

10.30 kW

COP Tj = Tbiv

3.45

2.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.78 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

0.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.00 kW

6.00 kW

Annual energy consumption Qhe

11631 kWh

14593 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

132 %

COP

3.30

Heating up time

01:34 h:min

Standby power input

48.0 W

Reference hot water temperature

54.2 °C

Mixed water at 40°C

430 l

Colder Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

97 %

COP

2.43

Heating up time

02:15 h:min

Standby power input

63.0 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

422 l

Average Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

122 %

COP

3.06

Heating up time

01:52 h:min

Standby power input

53.0 W

Reference hot water temperature

54.5 °C

Mixed water at 40°C

434 l

ARIANEXT COMPACT 110 S
Configure model
Model name
ARIANEXT COMPACT 110 S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

127 %

COP

3.01

Heating up time

00:47 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

247 l

ARIANEXT FLEX 110 S
Configure model
Model name
ARIANEXT FLEX 110 S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

127 %

COP

3.01

Heating up time

00:47 h:min

Standby power input

38.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

247 l

ARIANEXT FLEX 110 S - 300
Configure model
Model name
ARIANEXT FLEX 110 S - 300
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.60 kW

9.55 kW

El input

2.06 kW

3.02 kW

COP

5.15

3.17

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

12.29 kW

11.54 kW

ηs

187 %

135 %

Prated

12.29 kW

11.54 kW

SCOP

4.74

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.87 kW

10.21 kW

COP Tj = -7°C

3.21

2.32

Pdh Tj = +2°C

6.67 kW

6.21 kW

COP Tj = +2°C

4.52

3.32

Pdh Tj = +7°C

4.33 kW

3.99 kW

COP Tj = +7°C

6.12

4.38

Pdh Tj = 12°C

4.42 kW

4.27 kW

COP Tj = 12°C

9.15

6.59

Pdh Tj = Tbiv

10.87 kW

10.21 kW

COP Tj = Tbiv

3.21

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.08 kW

10.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

19 W

19 W

PSB

18 W

18 W

PCK

18 W

18 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.08 kW

1.18 kW

Annual energy consumption Qhe

5358 kWh

6891 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

131 %

COP

3.10

Heating up time

01:52 h:min

Standby power input

61.0 W

Reference hot water temperature

54.4 °C

Mixed water at 40°C

434 l