2,300 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.05 kW
13.96 kW
El input
3.53 kW
4.98 kW
COP
4.27
2.81
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
69 dB(A)
69 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
132 %
Prated
11.65 kW
10.88 kW
SCOP
4.60
3.37
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.30 kW
9.63 kW
COP Tj = -7°C
2.76
1.98
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.21 kW
5.90 kW
COP Tj = +2°C
4.37
3.17
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.82 kW
7.23 kW
COP Tj = +7°C
6.42
4.77
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
9.10 kW
8.77 kW
COP Tj = 12°C
8.93
7.12
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
10.30 kW
9.63 kW
COP Tj = Tbiv
2.76
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.32 kW
9.46 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.71
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
61 °C
61 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.33 kW
1.42 kW
Annual energy consumption Qhe
5230 kWh
6665 kWh