1,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.95 kW
8.16 kW
El input
2.10 kW
2.96 kW
COP
4.26
2.76
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
182 %
136 %
Prated
7.27 kW
5.70 kW
SCOP
4.63
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.43 kW
5.04 kW
COP Tj = -7°C
2.80
1.92
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.98 kW
3.07 kW
COP Tj = +2°C
4.43
3.37
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.94 kW
3.78 kW
COP Tj = +7°C
6.33
4.84
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
4.68 kW
4.52 kW
COP Tj = 12°C
8.98
7.23
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
6.43 kW
5.04 kW
COP Tj = Tbiv
2.80
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.75 kW
5.62 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.71
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
57 °C
57 °C
Poff
7 W
7 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.53 kW
0.08 kW
Annual energy consumption Qhe
3244 kWh
3378 kWh