Chappée ERIA S PLUS DUO R32 8-10

Certificate Holder
BDR Thermea FR (CHAPPEE)
57 rue de la Gare
67580 Mertzwiller
France
Registration number
007-DN0133
Certification Body
Kiwa Nederland B.V.
Subtype title
Chappée ERIA S PLUS DUO R32 8-10
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,650 kg

Certification Date
11.11.2022
Testing basis
European KEYMARK Scheme for Heat Pumps (v10)
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

ERIA S PLUS DUO R32 8 MR/EM
Configure model
Model name
ERIA S PLUS DUO R32 8 MR/EM
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.30 kW

7.50 kW

El input

1.60 kW

2.36 kW

COP

5.20

3.18

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

7.33 kW

8.47 kW

Cooling capacity

2.17

1.66

EER

3.38

5.11

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.33 kW

8.47 kW

SEER

4.85

8.07

Pdc Tj = 35°C

7.33 kW

8.47 kW

EER Tj = 35°C

3.38

5.11

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

5.56 kW

6.68 kW

EER Tj = 30°C

4.53

7.14

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

3.63 kW

4.21 kW

EER Tj = 25°C

5.37

8.53

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

1.56 kW

1.70 kW

EER Tj = 20°C

5.56

11.68

Cdc Tj = 20 °C

0.900

0.900

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

906 kWh

630 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

132 %

Prated

8.12 kW

6.60 kW

SCOP

5.21

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.19 kW

5.84 kW

COP Tj = -7°C

3.35

2.16

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.65 kW

3.76 kW

COP Tj = +2°C

5.09

3.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.90 kW

2.43 kW

COP Tj = +7°C

6.82

4.34

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.63 kW

1.40 kW

COP Tj = 12°C

8.35

5.33

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.19 kW

5.84 kW

COP Tj = Tbiv

3.35

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.45 kW

4.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.68 kW

1.69 kW

Annual energy consumption Qhe

3219 kWh

4053 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

128 %

COP

3.08

Heating up time

1:21 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

ERIA S PLUS DUO R32 10 MR/EM
Configure model
Model name
ERIA S PLUS DUO R32 10 MR/EM
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

9.50 kW

El input

2.00 kW

3.06 kW

COP

5.00

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

8.70 kW

10.24 kW

Cooling capacity

2.69

2.17

EER

3.23

4.71

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.70 kW

10.24 kW

SEER

4.94

7.78

Pdc Tj = 35°C

8.70 kW

10.24 kW

EER Tj = 35°C

3.23

4.71

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

6.46 kW

7.98 kW

EER Tj = 30°C

4.38

6.58

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

3.90 kW

4.54 kW

EER Tj = 25°C

5.51

8.27

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

1.90 kW

2.13 kW

EER Tj = 20°C

5.96

11.65

Cdc Tj = 20 °C

0.900

0.900

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1058 kWh

790 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

137 %

Prated

9.17 kW

7.67 kW

SCOP

5.20

3.49

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.11 kW

6.78 kW

COP Tj = -7°C

3.23

2.24

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.95 kW

4.29 kW

COP Tj = +2°C

5.01

3.42

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.32 kW

2.77 kW

COP Tj = +7°C

7.08

4.52

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.65 kW

1.58 kW

COP Tj = 12°C

8.58

5.68

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.11 kW

6.78 kW

COP Tj = Tbiv

3.23

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.40 kW

5.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.96

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.76 kW

2.28 kW

Annual energy consumption Qhe

3646 kWh

4538 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

128 %

COP

3.08

Heating up time

1:21 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

ERIA S PLUS DUO R32 8 MR/H
Configure model
Model name
ERIA S PLUS DUO R32 8 MR/H
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.30 kW

7.50 kW

El input

1.60 kW

2.36 kW

COP

5.20

3.18

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

7.33 kW

8.47 kW

Cooling capacity

2.17

1.66

EER

3.38

5.11

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.33 kW

8.47 kW

SEER

4.85

8.07

Pdc Tj = 35°C

7.33 kW

8.47 kW

EER Tj = 35°C

3.38

5.11

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

5.56 kW

6.68 kW

EER Tj = 30°C

4.53

7.14

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

3.63 kW

4.21 kW

EER Tj = 25°C

5.37

8.53

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

1.56 kW

1.70 kW

EER Tj = 20°C

5.56

11.68

Cdc Tj = 20 °C

0.900

0.900

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

906 kWh

630 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

132 %

Prated

8.12 kW

6.60 kW

SCOP

5.21

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.19 kW

5.84 kW

COP Tj = -7°C

3.35

2.16

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.65 kW

3.76 kW

COP Tj = +2°C

5.09

3.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.90 kW

2.43 kW

COP Tj = +7°C

6.82

4.34

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.63 kW

1.40 kW

COP Tj = 12°C

8.35

5.33

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.19 kW

5.84 kW

COP Tj = Tbiv

3.35

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.45 kW

4.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.68 kW

1.69 kW

Annual energy consumption Qhe

3219 kWh

4053 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

128 %

COP

3.08

Heating up time

1:21 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

ERIA S PLUS DUO R32 10 MR/H
Configure model
Model name
ERIA S PLUS DUO R32 10 MR/H
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

9.50 kW

El input

2.00 kW

3.06 kW

COP

5.00

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

8.70 kW

10.24 kW

Cooling capacity

2.69

2.17

EER

3.23

4.71

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.70 kW

10.24 kW

SEER

4.94

7.78

Pdc Tj = 35°C

8.70 kW

10.24 kW

EER Tj = 35°C

3.23

4.71

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

6.46 kW

7.98 kW

EER Tj = 30°C

4.38

6.58

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

3.90 kW

4.54 kW

EER Tj = 25°C

5.51

8.27

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

1.90 kW

2.13 kW

EER Tj = 20°C

5.96

11.65

Cdc Tj = 20 °C

0.900

0.900

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1058 kWh

790 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

137 %

Prated

9.17 kW

7.67 kW

SCOP

5.20

3.49

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.11 kW

6.78 kW

COP Tj = -7°C

3.23

2.24

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.95 kW

4.29 kW

COP Tj = +2°C

5.01

3.42

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.32 kW

2.77 kW

COP Tj = +7°C

7.08

4.52

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.65 kW

1.58 kW

COP Tj = 12°C

8.58

5.68

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.11 kW

6.78 kW

COP Tj = Tbiv

3.23

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.40 kW

5.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.96

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.76 kW

2.28 kW

Annual energy consumption Qhe

3646 kWh

4538 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

128 %

COP

3.08

Heating up time

1:21 h:min

Standby power input

27.6 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l