Certificate holders

Subtype

SHERPA MONOBLOC S2 E SERIES 6 8 10 kW

Certificate Holder
Olimpia Splendid S.p.A.
Via Industriale, 1/3
25060 Cellatica (BS)
Italy
Registration number
041-K028-01
Certification Body
BRE
Subtype title
SHERPA MONOBLOC S2 E SERIES 6 8 10 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,250 kg

Certification Date
14.10.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 3

Models

SHERPA MONOBLOC S2 E 6
Configure model
Model name
SHERPA MONOBLOC S2 E 6
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.5 kW

6.3 kW

El input

1.23 kW

1.97 kW

COP

5.3

3.2

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

268.2 %

170.9 %

Prated

6.24 kW

6.17 kW

SCOP

6.78

4.35

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.69 kW

6.17 kW

COP Tj = +2°C

4.31

2.77

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

4.01 kW

3.97 kW

COP Tj = +7°C

6.39

3.9

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

2.07 kW

2.06 kW

COP Tj = 12°C

8.71

5.28

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

4.01 kW

3.97 kW

COP Tj = Tbiv

6.39

3.9

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.69 kW

6.17 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.31

2.77

WTOL

65 °C

65 °C

Poff

13 W

13 W

PTO

20 W

20 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.55 kW

0 kW

Annual energy consumption Qhe

1229 kWh

1895 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173.4 %

113.12 %

Prated

6.13 kW

5.22 kW

SCOP

4.41

2.9

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.11 kW

3.21 kW

COP Tj = -7°C

3.76

2.6

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

2.38 kW

2.03 kW

COP Tj = +2°C

5.33

3.18

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

1.66 kW

1.56 kW

COP Tj = +7°C

5.78

4.5

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.87 kW

1.44 kW

COP Tj = 12°C

9.12

5.83

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

5 kW

4.25 kW

COP Tj = Tbiv

3.02

2

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.21 kW

3.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.12

1.32

WTOL

65 °C

65 °C

Poff

13 W

13 W

PTO

20 W

20 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.92 kW

1.98 kW

Annual energy consumption Qhe

3425 kWh

4428 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5

4.25

COP Tj = -15°C (if TOL<-20°C)

3.02

2

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

201.8 %

140.72 %

Prated

6.52 kW

6.36 kW

SCOP

5.12

3.59

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.77 kW

5.62 kW

COP Tj = -7°C

3.43

2.36

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

3.74 kW

3.52 kW

COP Tj = +2°C

5.04

3.7

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

2.32 kW

2.2 kW

COP Tj = +7°C

6.06

4.21

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.87 kW

1.31 kW

COP Tj = 12°C

9.12

4.96

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

5.77 kW

5.62 kW

COP Tj = Tbiv

3.43

2.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.52 kW

6.04 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3

2.02

WTOL

65 °C

65 °C

Poff

13 W

13 W

PTO

20 W

20 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0.32 kW

Annual energy consumption Qhe

2631 kWh

3655 kWh

SHERPA MONOBLOC S2 E 8
Configure model
Model name
SHERPA MONOBLOC S2 E 8
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.40 kW

8.20 kW

El input

1.66 kW

2.60 kW

COP

5.05

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

274.74 %

185.3 %

Prated

8.06 kW

8.10 kW

SCOP

6.94

4.71

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.23 kW

7.80 kW

COP Tj = +2°C

4.04

2.68

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.18 kW

5.22 kW

COP Tj = +7°C

6.35

4.07

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

2.46 kW

2.36 kW

COP Tj = 12°C

9.30

6.07

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

5.18 kW

5.22 kW

COP Tj = Tbiv

6.35

4.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.23 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.04

2.68

WTOL

65.00 °C

65.00 °C

Poff

13.00 W

13.00 W

PTO

20.00 W

20.00 W

PSB

13.00 W

13.00 W

PCK

0.00 W

0.00 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.84 kW

0.32 kW

Annual energy consumption Qhe

1551 kWh

2303 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

174.6 %

117.73 %

Prated

7.51 kW

6.06 kW

SCOP

4.44

3.02

Tbiv

-15.00 °C

-15.00 °C

TOL

-22.00 °C

-22.00 °C

Pdh Tj = -7°C

4.42 kW

3.95 kW

COP Tj = -7°C

3.67

2.75

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

2.99 kW

2.25 kW

COP Tj = +2°C

5.50

3.30

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

2.03 kW

1.56 kW

COP Tj = +7°C

6.69

4.50

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

1.87 kW

1.44 kW

COP Tj = 12°C

9.12

5.83

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

6.12 kW

4.94 kW

COP Tj = Tbiv

2.70

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.78 kW

3.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.32

WTOL

65.00 °C

65.00 °C

Poff

13.00 W

13.00 W

PTO

20.00 W

20.00 W

PSB

13.00 W

13.00 W

PCK

0.00 W

0.00 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.72 kW

2.82 kW

Annual energy consumption Qhe

4166 kWh

4948 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.12

4.94

COP Tj = -15°C (if TOL<-20°C)

2.70

2.08

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203.99 %

143.64 %

Prated

7.90 kW

7.25 kW

SCOP

5.17

3.67

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.99 kW

6.42 kW

COP Tj = -7°C

3.29

2.31

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.51 kW

4.03 kW

COP Tj = +2°C

4.99

3.76

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

2.81 kW

2.56 kW

COP Tj = +7°C

6.72

4.48

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

1.87 kW

1.31 kW

COP Tj = 12°C

9.12

4.96

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

6.99 kW

6.42 kW

COP Tj = Tbiv

3.29

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.46 kW

6.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

1.98

WTOL

65.00 °C

65.00 °C

Poff

13.00 W

13.00 W

PTO

20.00 W

20.00 W

PSB

13.00 W

13.00 W

PCK

0.00 W

0.00 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.44 kW

0.40 kW

Annual energy consumption Qhe

3155 kWh

4088 kWh

SHERPA MONOBLOC S2 E 10
Configure model
Model name
SHERPA MONOBLOC S2 E 10
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10 kW

9.4 kW

El input

2.13 kW

3.03 kW

COP

4.7

3.1

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

279.05 %

193.4 %

Prated

9.04 kW

9.03 kW

SCOP

7.05

4.91

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.29 kW

8.42 kW

COP Tj = +2°C

3.85

2.68

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.81 kW

5.81 kW

COP Tj = +7°C

6.24

4.16

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

2.67 kW

2.74 kW

COP Tj = 12°C

9.63

6.64

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

5.81 kW

5.81 kW

COP Tj = Tbiv

6.24

4.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.29 kW

8.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.85

2.68

WTOL

65 °C

65 °C

Poff

13 W

13 W

PTO

20 W

20 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.75 kW

0.61 kW

Annual energy consumption Qhe

1714 kWh

2458 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

174.6 %

122.4 %

Prated

8.27 kW

7.21 kW

SCOP

4.44

3.14

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.42 kW

4.59 kW

COP Tj = -7°C

3.72

2.72

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

3.14 kW

2.82 kW

COP Tj = +2°C

5.56

3.6

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

2.16 kW

1.76 kW

COP Tj = +7°C

6.55

4.84

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.87 kW

1.44 kW

COP Tj = 12°C

9.12

5.83

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

6.75 kW

5.88 kW

COP Tj = Tbiv

2.59

2.1

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.08 kW

3.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.01

1.32

WTOL

65 °C

65 °C

Poff

13 W

13 W

PTO

20 W

20 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.19 kW

3.97 kW

Annual energy consumption Qhe

4591 kWh

5665 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.75

5.88

COP Tj = -15°C (if TOL<-20°C)

2.59

2.1

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

201.91 %

145.47 %

Prated

9.06 kW

8.16 kW

SCOP

5.12

3.71

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.02 kW

7.21 kW

COP Tj = -7°C

3.09

2.24

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

5.06 kW

4.56 kW

COP Tj = +2°C

4.92

3.86

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

3.22 kW

2.84 kW

COP Tj = +7°C

7.03

4.58

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.87 kW

1.31 kW

COP Tj = 12°C

9.12

4.96

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

8.02 kW

7.21 kW

COP Tj = Tbiv

3.09

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.88 kW

7.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

1.97

WTOL

65 °C

65 °C

Poff

13 W

13 W

PTO

20 W

20 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.18 kW

1.14 kW

Annual energy consumption Qhe

3654 kWh

4539 kWh