Certificate holders

Subtype

DAIKIN ALTHERMA 3 H HT ECH2O 14-18kW (300L)

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0524
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA 3 H HT ECH2O 14-18kW (300L)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

4,200 kg

Certification Date
24.03.2022
Testing basis
HP KEYMARK certification scheme rules rev. 10
Generate PDF Export model CSV
  • Number of models 24

Models

EPRA14DV3 / ETSH(B)16P30E
Configure model
Model name
EPRA14DV3 / ETSH(B)16P30E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

0.99

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

0.98

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

0.98

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

124 %

COP

2.86

Heating up time

1:25 h:min

Standby power input

57.4 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA14DV3 / ETSX(B)16P30E
Configure model
Model name
EPRA14DV3 / ETSX(B)16P30E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

0.99

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

0.98

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

0.98

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

142 %

Prated

12.5 kW

12.5 kW

SCOP

4.57

3.62

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5649 kWh

7134 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

124 %

COP

2.86

Heating up time

1:25 h:min

Standby power input

57.4 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA14DW1 / ETSH(B)16P30E
Configure model
Model name
EPRA14DW1 / ETSH(B)16P30E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

0.97

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

124 %

COP

2.85

Heating up time

1:25 h:min

Standby power input

57.7 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA14DW1 / ETSX(B)16P30E
Configure model
Model name
EPRA14DW1 / ETSX(B)16P30E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

0.97

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

142 %

Prated

12.5 kW

12.5 kW

SCOP

4.81

3.63

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5366 kWh

7122 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

124 %

COP

2.85

Heating up time

1:25 h:min

Standby power input

57.7 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA16DV3 / ETSH(B)16P30E
Configure model
Model name
EPRA16DV3 / ETSH(B)16P30E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.41 kW

COP

5

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.93 kW

Cooling capacity

7.88

EER

2.69

EN 14825

+7°C/+12°C

Pdesignc

7.9 kW

SEER

4.08

Pdc Tj = 35°C

7.88 kW

EER Tj = 35°C

2.69

Pdc Tj = 30°C

5.92 kW

EER Tj = 30°C

3.69

Cdc Tj = 30 °C

0.99

Pdc Tj = 25°C

5.09 kW

EER Tj = 25°C

4.63

Cdc Tj = 25 °C

0.98

Pdc Tj = 20°C

5.13 kW

EER Tj = 20°C

5.61

Cdc Tj = 20 °C

0.98

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1158 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

124 %

COP

2.86

Heating up time

1:25 h:min

Standby power input

57.4 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA16DV3 / ETSX(B)16P30E
Configure model
Model name
EPRA16DV3 / ETSX(B)16P30E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.41 kW

COP

5

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.93 kW

Cooling capacity

7.88

EER

2.69

EN 14825

+7°C/+12°C

Pdesignc

7.9 kW

SEER

4.08

Pdc Tj = 35°C

7.88 kW

EER Tj = 35°C

2.69

Pdc Tj = 30°C

5.92 kW

EER Tj = 30°C

3.69

Cdc Tj = 30 °C

0.99

Pdc Tj = 25°C

5.09 kW

EER Tj = 25°C

4.63

Cdc Tj = 25 °C

0.98

Pdc Tj = 20°C

5.13 kW

EER Tj = 20°C

5.61

Cdc Tj = 20 °C

0.98

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1158 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

142 %

Prated

12.5 kW

12.5 kW

SCOP

4.57

3.62

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5649 kWh

7134 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

124 %

COP

2.86

Heating up time

1:25 h:min

Standby power input

57.4 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA16DW1 / ETSH(B)16P30E
Configure model
Model name
EPRA16DW1 / ETSH(B)16P30E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.47 kW

COP

5

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.93 kW

Cooling capacity

7.88

EER

2.69

EN 14825

+7°C/+12°C

Pdesignc

7.9 kW

SEER

3.98

Pdc Tj = 35°C

7.88 kW

EER Tj = 35°C

2.69

Pdc Tj = 30°C

5.92 kW

EER Tj = 30°C

3.69

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

5.09 kW

EER Tj = 25°C

4.63

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

5.13 kW

EER Tj = 20°C

5.61

Cdc Tj = 20 °C

0.97

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1188 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

124 %

COP

2.85

Heating up time

1:25 h:min

Standby power input

57.7 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA16DW1 / ETSX(B)16P30E
Configure model
Model name
EPRA16DW1 / ETSX(B)16P30E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.47 kW

COP

5

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.93 kW

Cooling capacity

7.88

EER

2.69

EN 14825

+7°C/+12°C

Pdesignc

7.9 kW

SEER

3.98

Pdc Tj = 35°C

7.88 kW

EER Tj = 35°C

2.69

Pdc Tj = 30°C

5.92 kW

EER Tj = 30°C

3.69

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

5.09 kW

EER Tj = 25°C

4.63

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

5.13 kW

EER Tj = 20°C

5.61

Cdc Tj = 20 °C

0.97

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1188 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

142 %

Prated

12.5 kW

12.5 kW

SCOP

4.81

3.63

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5366 kWh

7122 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

124 %

COP

2.85

Heating up time

1:25 h:min

Standby power input

57.7 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA18DV3 / ETSH(B)16P30E
Configure model
Model name
EPRA18DV3 / ETSH(B)16P30E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.41 kW

COP

5

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.31 kW

Cooling capacity

8.86

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

8.8 kW

SEER

4.17

Pdc Tj = 35°C

8.86 kW

EER Tj = 35°C

2.68

Pdc Tj = 30°C

6.61 kW

EER Tj = 30°C

3.72

Cdc Tj = 30 °C

0.99

Pdc Tj = 25°C

5.12 kW

EER Tj = 25°C

4.68

Cdc Tj = 25 °C

0.98

Pdc Tj = 20°C

5.31 kW

EER Tj = 20°C

5.81

Cdc Tj = 20 °C

0.98

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1266 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

124 %

COP

2.86

Heating up time

1:25 h:min

Standby power input

57.4 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA18DV3 / ETSX(B)16P30E
Configure model
Model name
EPRA18DV3 / ETSX(B)16P30E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.41 kW

COP

5

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.31 kW

Cooling capacity

8.86

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

8.8 kW

SEER

4.17

Pdc Tj = 35°C

8.86 kW

EER Tj = 35°C

2.68

Pdc Tj = 30°C

6.61 kW

EER Tj = 30°C

3.72

Cdc Tj = 30 °C

0.99

Pdc Tj = 25°C

5.12 kW

EER Tj = 25°C

4.68

Cdc Tj = 25 °C

0.98

Pdc Tj = 20°C

5.31 kW

EER Tj = 20°C

5.81

Cdc Tj = 20 °C

0.98

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1266 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

142 %

Prated

12.5 kW

12.5 kW

SCOP

4.57

3.62

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5649 kWh

7134 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

124 %

COP

2.86

Heating up time

1:25 h:min

Standby power input

57.4 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA18DW1 / ETSH(B)16P30E
Configure model
Model name
EPRA18DW1 / ETSH(B)16P30E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.47 kW

COP

5

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.31 kW

Cooling capacity

8.86

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

8.8 kW

SEER

4.07

Pdc Tj = 35°C

8.86 kW

EER Tj = 35°C

2.68

Pdc Tj = 30°C

6.61 kW

EER Tj = 30°C

3.72

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

5.12 kW

EER Tj = 25°C

4.68

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

5.31 kW

EER Tj = 20°C

5.81

Cdc Tj = 20 °C

0.97

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1296 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

124 %

COP

2.85

Heating up time

1:25 h:min

Standby power input

57.7 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA18DW1 / ETSX(B)16P30E
Configure model
Model name
EPRA18DW1 / ETSX(B)16P30E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.47 kW

COP

5

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.31 kW

Cooling capacity

8.86

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

8.8 kW

SEER

4.07

Pdc Tj = 35°C

8.86 kW

EER Tj = 35°C

2.68

Pdc Tj = 30°C

6.61 kW

EER Tj = 30°C

3.72

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

5.12 kW

EER Tj = 25°C

4.68

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

5.31 kW

EER Tj = 20°C

5.81

Cdc Tj = 20 °C

0.97

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1296 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

142 %

Prated

12.5 kW

12.5 kW

SCOP

4.81

3.63

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5366 kWh

7122 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

124 %

COP

2.85

Heating up time

1:25 h:min

Standby power input

57.7 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA14DV37 / ETSH(B)16P30E(7)
Configure model
Model name
EPRA14DV37 / ETSH(B)16P30E(7)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

0.99

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

0.98

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

0.98

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

126.1 %

COP

2.91

Heating up time

1:36 h:min

Standby power input

56.9 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA14DV37 / ETSX(B)16P30E(7)
Configure model
Model name
EPRA14DV37 / ETSX(B)16P30E(7)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

0.99

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

0.98

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

0.98

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

142 %

Prated

12.5 kW

12.5 kW

SCOP

4.57

3.62

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5649 kWh

7134 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

126.1 %

COP

2.91

Heating up time

1:36 h:min

Standby power input

56.9 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA14DW17 / ETSH(B)16P30E(7)
Configure model
Model name
EPRA14DW17 / ETSH(B)16P30E(7)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

0.97

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

125.5 %

COP

2.89

Heating up time

1:36 h:min

Standby power input

57.2 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA14DW17 / ETSX(B)16P30E(7)
Configure model
Model name
EPRA14DW17 / ETSX(B)16P30E(7)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

0.97

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

142 %

Prated

12.5 kW

12.5 kW

SCOP

4.81

3.63

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5366 kWh

7122 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

125.5 %

COP

2.89

Heating up time

1:36 h:min

Standby power input

57.2 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA16DV37 / ETSH(B)16P30E(7)
Configure model
Model name
EPRA16DV37 / ETSH(B)16P30E(7)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.41 kW

COP

5

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.93 kW

Cooling capacity

7.88

EER

2.69

EN 14825

+7°C/+12°C

Pdesignc

7.9 kW

SEER

4.08

Pdc Tj = 35°C

7.88 kW

EER Tj = 35°C

2.69

Pdc Tj = 30°C

5.92 kW

EER Tj = 30°C

3.69

Cdc Tj = 30 °C

0.99

Pdc Tj = 25°C

5.09 kW

EER Tj = 25°C

4.63

Cdc Tj = 25 °C

0.98

Pdc Tj = 20°C

5.13 kW

EER Tj = 20°C

5.61

Cdc Tj = 20 °C

0.98

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1158 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

126.1 %

COP

2.91

Heating up time

1:36 h:min

Standby power input

56.9 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA16DV37 / ETSX(B)16P30E(7)
Configure model
Model name
EPRA16DV37 / ETSX(B)16P30E(7)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.41 kW

COP

5

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.93 kW

Cooling capacity

7.88

EER

2.69

EN 14825

+7°C/+12°C

Pdesignc

7.9 kW

SEER

4.08

Pdc Tj = 35°C

7.88 kW

EER Tj = 35°C

2.69

Pdc Tj = 30°C

5.92 kW

EER Tj = 30°C

3.69

Cdc Tj = 30 °C

0.99

Pdc Tj = 25°C

5.09 kW

EER Tj = 25°C

4.63

Cdc Tj = 25 °C

0.98

Pdc Tj = 20°C

5.13 kW

EER Tj = 20°C

5.61

Cdc Tj = 20 °C

0.98

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1158 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

142 %

Prated

12.5 kW

12.5 kW

SCOP

4.57

3.62

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5649 kWh

7134 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

126.1 %

COP

2.91

Heating up time

1:36 h:min

Standby power input

56.9 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA16DW17 / ETSH(B)16P30E(7)
Configure model
Model name
EPRA16DW17 / ETSH(B)16P30E(7)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.47 kW

COP

5

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.93 kW

Cooling capacity

7.88

EER

2.69

EN 14825

+7°C/+12°C

Pdesignc

7.9 kW

SEER

3.98

Pdc Tj = 35°C

7.88 kW

EER Tj = 35°C

2.69

Pdc Tj = 30°C

5.92 kW

EER Tj = 30°C

3.69

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

5.09 kW

EER Tj = 25°C

4.63

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

5.13 kW

EER Tj = 20°C

5.61

Cdc Tj = 20 °C

0.97

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1188 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

125.5 %

COP

2.89

Heating up time

1:36 h:min

Standby power input

57.2 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA16DW17 / ETSX(B)16P30E(7)
Configure model
Model name
EPRA16DW17 / ETSX(B)16P30E(7)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.47 kW

COP

5

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.93 kW

Cooling capacity

7.88

EER

2.69

EN 14825

+7°C/+12°C

Pdesignc

7.9 kW

SEER

3.98

Pdc Tj = 35°C

7.88 kW

EER Tj = 35°C

2.69

Pdc Tj = 30°C

5.92 kW

EER Tj = 30°C

3.69

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

5.09 kW

EER Tj = 25°C

4.63

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

5.13 kW

EER Tj = 20°C

5.61

Cdc Tj = 20 °C

0.97

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1188 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

142 %

Prated

12.5 kW

12.5 kW

SCOP

4.81

3.63

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5366 kWh

7122 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

125.5 %

COP

2.89

Heating up time

1:36 h:min

Standby power input

57.2 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA18DV37 / ETSH(B)16P30E(7)
Configure model
Model name
EPRA18DV37 / ETSH(B)16P30E(7)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.41 kW

COP

5

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.31 kW

Cooling capacity

8.86

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

8.8 kW

SEER

4.17

Pdc Tj = 35°C

8.86 kW

EER Tj = 35°C

2.68

Pdc Tj = 30°C

6.61 kW

EER Tj = 30°C

3.72

Cdc Tj = 30 °C

0.99

Pdc Tj = 25°C

5.12 kW

EER Tj = 25°C

4.68

Cdc Tj = 25 °C

0.98

Pdc Tj = 20°C

5.31 kW

EER Tj = 20°C

5.81

Cdc Tj = 20 °C

0.98

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1266 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

126.1 %

COP

2.91

Heating up time

1:36 h:min

Standby power input

56.9 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA18DV37 / ETSX(B)16P30E(7)
Configure model
Model name
EPRA18DV37 / ETSX(B)16P30E(7)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.41 kW

COP

5

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.31 kW

Cooling capacity

8.86

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

8.8 kW

SEER

4.17

Pdc Tj = 35°C

8.86 kW

EER Tj = 35°C

2.68

Pdc Tj = 30°C

6.61 kW

EER Tj = 30°C

3.72

Cdc Tj = 30 °C

0.99

Pdc Tj = 25°C

5.12 kW

EER Tj = 25°C

4.68

Cdc Tj = 25 °C

0.98

Pdc Tj = 20°C

5.31 kW

EER Tj = 20°C

5.81

Cdc Tj = 20 °C

0.98

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1266 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

142 %

Prated

12.5 kW

12.5 kW

SCOP

4.57

3.62

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5649 kWh

7134 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

126.1 %

COP

2.91

Heating up time

1:36 h:min

Standby power input

56.9 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA18DW17 / ETSH(B)16P30E(7)
Configure model
Model name
EPRA18DW17 / ETSH(B)16P30E(7)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.47 kW

COP

5

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.31 kW

Cooling capacity

8.86

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

8.8 kW

SEER

4.07

Pdc Tj = 35°C

8.86 kW

EER Tj = 35°C

2.68

Pdc Tj = 30°C

6.61 kW

EER Tj = 30°C

3.72

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

5.12 kW

EER Tj = 25°C

4.68

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

5.31 kW

EER Tj = 20°C

5.81

Cdc Tj = 20 °C

0.97

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1296 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

125.5 %

COP

2.89

Heating up time

1:36 h:min

Standby power input

57.2 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l

EPRA18DW17 / ETSX(B)16P30E(7)
Configure model
Model name
EPRA18DW17 / ETSX(B)16P30E(7)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9 kW

7.24 kW

El input

1.8 kW

2.47 kW

COP

5

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

3.31 kW

Cooling capacity

8.86

EER

2.68

EN 14825

+7°C/+12°C

Pdesignc

8.8 kW

SEER

4.07

Pdc Tj = 35°C

8.86 kW

EER Tj = 35°C

2.68

Pdc Tj = 30°C

6.61 kW

EER Tj = 30°C

3.72

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

5.12 kW

EER Tj = 25°C

4.68

Cdc Tj = 25 °C

0.97

Pdc Tj = 20°C

5.31 kW

EER Tj = 20°C

5.81

Cdc Tj = 20 °C

0.97

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1296 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45.6 dB(A)

45.6 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

142 %

Prated

12.5 kW

12.5 kW

SCOP

4.81

3.63

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5366 kWh

7122 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

125.5 %

COP

2.89

Heating up time

1:36 h:min

Standby power input

57.2 W

Reference hot water temperature

47 °C

Mixed water at 40°C

193 l