2,750 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.50 kW
12.90 kW
El input
1.77 kW
4.31 kW
COP
4.79
2.99
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
131 %
Prated
13.50 kW
13.30 kW
SCOP
4.51
3.36
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.90 kW
11.80 kW
COP Tj = -7°C
3.04
2.24
Cdh Tj = -7 °C
0.970
0.980
Pdh Tj = +2°C
7.30 kW
7.20 kW
COP Tj = +2°C
4.70
3.38
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
8.60 kW
8.30 kW
COP Tj = +7°C
5.55
4.24
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
10.10 kW
9.80 kW
COP Tj = 12°C
6.53
5.06
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
11.90 kW
11.80 kW
COP Tj = Tbiv
3.09
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.10 kW
11.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.86
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
60 °C
60 °C
Poff
18 W
18 W
PTO
48 W
32 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.40 kW
2.10 kW
Annual energy consumption Qhe
6187 kWh
8179 kWh