DAIKIN ALTHERMA 3 R ECH2O 08KW (500L) (/A)

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0267
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA 3 R ECH2O 08KW (500L) (/A)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,500 kg

Certification Date
17.08.2018
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 9 (as of 2021-03)
Generate PDF Export model CSV
  • Number of models 12

Models

ERGA08EV / EHSH(B)08P50D3
Configure model
Model name
ERGA08EV / EHSH(B)08P50D3
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.63 kW

2.78 kW

COP

4.6

2.7

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.4 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc Tj = 20 °C

1

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

130 %

Prated

8 kW

8 kW

SCOP

4.56

3.32

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7 kW

6.9 kW

COP Tj = -7°C

2.77

1.96

Cdh Tj = -7 °C

n/a

1

Pdh Tj = +2°C

4.2 kW

4.4 kW

COP Tj = +2°C

4.35

3.2

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

3.3 kW

3.3 kW

COP Tj = +7°C

6.49

4.64

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.9 kW

4.1 kW

COP Tj = 12°C

8.52

6.22

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

7.5 kW

COP Tj = Tbiv

2.66

1.9

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.1 kW

0.94 kW

Annual energy consumption Qhe

3625 kWh

4975 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.57

Heating up time

2:47 h:min

Standby power input

38.2 W

Reference hot water temperature

45.2 °C

Mixed water at 40°C

237 l

ERGA08EV / EHSX(B)08P50D3
Configure model
Model name
ERGA08EV / EHSX(B)08P50D3
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.63 kW

2.78 kW

COP

4.6

2.7

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.4 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc Tj = 20 °C

1

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

131 %

Prated

8 kW

8 kW

SCOP

4.61

3.35

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7 kW

6.9 kW

COP Tj = -7°C

2.77

1.96

Cdh Tj = -7 °C

n/a

1

Pdh Tj = +2°C

4.2 kW

4.4 kW

COP Tj = +2°C

4.35

3.2

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

3.3 kW

3.3 kW

COP Tj = +7°C

6.49

4.64

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.9 kW

4.1 kW

COP Tj = 12°C

8.52

6.22

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

7.5 kW

COP Tj = Tbiv

2.66

1.9

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.1 kW

0.94 kW

Annual energy consumption Qhe

3588 kWh

4939 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.57

Heating up time

2:47 h:min

Standby power input

38.2 W

Reference hot water temperature

45.2 °C

Mixed water at 40°C

237 l

ERGA08EVA / EHSH(B)08P50D3
Configure model
Model name
ERGA08EVA / EHSH(B)08P50D3
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.63 kW

2.78 kW

COP

4.6

2.7

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.4 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc Tj = 20 °C

1

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

128 %

Prated

8 kW

8 kW

SCOP

4.56

3.27

Tbiv

-8 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7 kW

5.9 kW

COP Tj = -7°C

2.77

1.98

Cdh Tj = -7 °C

n/a

1

Pdh Tj = +2°C

4.2 kW

4.1 kW

COP Tj = +2°C

4.35

3.18

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

3.3 kW

3 kW

COP Tj = +7°C

6.49

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.9 kW

3.7 kW

COP Tj = 12°C

8.52

6.16

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

6.4 kW

COP Tj = Tbiv

2.66

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

4.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.43

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.1 kW

3.5 kW

Annual energy consumption Qhe

3625 kWh

4731 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.57

Heating up time

2:47 h:min

Standby power input

38.2 W

Reference hot water temperature

45.2 °C

Mixed water at 40°C

237 l

ERGA08EVA / EHSX(B)08P50D3
Configure model
Model name
ERGA08EVA / EHSX(B)08P50D3
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.63 kW

2.78 kW

COP

4.6

2.7

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.4 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc Tj = 20 °C

1

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

129 %

Prated

8 kW

8 kW

SCOP

4.61

3.3

Tbiv

-8 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7 kW

5.9 kW

COP Tj = -7°C

2.77

1.98

Cdh Tj = -7 °C

n/a

1

Pdh Tj = +2°C

4.2 kW

4.1 kW

COP Tj = +2°C

4.35

3.18

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

3.3 kW

3 kW

COP Tj = +7°C

6.49

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.9 kW

3.7 kW

COP Tj = 12°C

8.52

6.16

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

6.4 kW

COP Tj = Tbiv

2.66

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

4.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.43

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.1 kW

3.5 kW

Annual energy consumption Qhe

3588 kWh

4694 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.57

Heating up time

2:47 h:min

Standby power input

38.2 W

Reference hot water temperature

45.2 °C

Mixed water at 40°C

237 l

ERGA08EVH / EHSH(B)08P50D3
Configure model
Model name
ERGA08EVH / EHSH(B)08P50D3
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.63 kW

2.78 kW

COP

4.6

2.7

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.4 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc Tj = 20 °C

1

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

130 %

Prated

8 kW

8 kW

SCOP

4.56

3.32

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7 kW

6.9 kW

COP Tj = -7°C

2.77

1.96

Cdh Tj = -7 °C

n/a

1

Pdh Tj = +2°C

4.2 kW

4.4 kW

COP Tj = +2°C

4.35

3.2

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

3.3 kW

3.3 kW

COP Tj = +7°C

6.49

4.64

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.9 kW

4.1 kW

COP Tj = 12°C

8.52

6.22

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

7.5 kW

COP Tj = Tbiv

2.66

1.9

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.1 kW

0.94 kW

Annual energy consumption Qhe

3625 kWh

4975 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.57

Heating up time

2:47 h:min

Standby power input

38.2 W

Reference hot water temperature

45.2 °C

Mixed water at 40°C

237 l

ERGA08EVH / EHSX(B)08P50D3
Configure model
Model name
ERGA08EVH / EHSX(B)08P50D3
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.63 kW

2.78 kW

COP

4.6

2.7

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.4 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc Tj = 20 °C

1

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

131 %

Prated

8 kW

8 kW

SCOP

4.61

3.35

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7 kW

6.9 kW

COP Tj = -7°C

2.77

1.96

Cdh Tj = -7 °C

n/a

1

Pdh Tj = +2°C

4.2 kW

4.4 kW

COP Tj = +2°C

4.35

3.2

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

3.3 kW

3.3 kW

COP Tj = +7°C

6.49

4.64

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.9 kW

4.1 kW

COP Tj = 12°C

8.52

6.22

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

7.5 kW

COP Tj = Tbiv

2.66

1.9

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.1 kW

0.94 kW

Annual energy consumption Qhe

3588 kWh

4939 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

106 %

COP

2.57

Heating up time

2:47 h:min

Standby power input

38.2 W

Reference hot water temperature

45.2 °C

Mixed water at 40°C

237 l

ERGA08EVA / EHSH(B)08P50E
Configure model
Model name
ERGA08EVA / EHSH(B)08P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.63 kW

2.78 kW

COP

4.6

2.7

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.4 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc Tj = 20 °C

1

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

128 %

Prated

8 kW

7.5 kW

SCOP

4.56

3.27

Tbiv

-8 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7 kW

5.9 kW

COP Tj = -7°C

2.77

1.98

Cdh Tj = -7 °C

n/a

1

Pdh Tj = +2°C

4.2 kW

4.1 kW

COP Tj = +2°C

4.35

3.18

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

3.3 kW

3 kW

COP Tj = +7°C

6.49

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.9 kW

3.7 kW

COP Tj = 12°C

8.52

6.16

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

6.4 kW

COP Tj = Tbiv

2.66

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

4.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.43

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.1 kW

3.1 kW

Annual energy consumption Qhe

3625 kWh

4731 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

125 %

COP

3.06

Heating up time

2:41 h:min

Standby power input

25.3 W

Reference hot water temperature

44.6 °C

Mixed water at 40°C

227.9 l

ERGA08EVA / EHSX(B)08P50E
Configure model
Model name
ERGA08EVA / EHSX(B)08P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.63 kW

2.78 kW

COP

4.6

2.7

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.4 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc Tj = 20 °C

1

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

129 %

Prated

8 kW

7.5 kW

SCOP

4.61

3.3

Tbiv

-8 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7 kW

5.9 kW

COP Tj = -7°C

2.77

1.98

Cdh Tj = -7 °C

n/a

1

Pdh Tj = +2°C

4.2 kW

4.1 kW

COP Tj = +2°C

4.35

3.18

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

3.3 kW

3 kW

COP Tj = +7°C

6.49

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.9 kW

3.7 kW

COP Tj = 12°C

8.52

6.16

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

6.4 kW

COP Tj = Tbiv

2.66

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

4.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.43

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.1 kW

3.1 kW

Annual energy consumption Qhe

3588 kWh

4694 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

125 %

COP

3.06

Heating up time

2:41 h:min

Standby power input

25.3 W

Reference hot water temperature

44.6 °C

Mixed water at 40°C

227.9 l

ERGA08EVH / EHSH(B)08P50E
Configure model
Model name
ERGA08EVH / EHSH(B)08P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.63 kW

2.78 kW

COP

4.6

2.7

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.4 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc Tj = 20 °C

1

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

130 %

Prated

8 kW

8 kW

SCOP

4.56

3.32

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7 kW

6.9 kW

COP Tj = -7°C

2.77

1.96

Cdh Tj = -7 °C

n/a

1

Pdh Tj = +2°C

4.2 kW

4.4 kW

COP Tj = +2°C

4.35

3.2

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

3.3 kW

3.3 kW

COP Tj = +7°C

6.49

4.64

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.9 kW

4.1 kW

COP Tj = 12°C

8.52

6.22

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

7.5 kW

COP Tj = Tbiv

2.66

1.9

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.1 kW

0.94 kW

Annual energy consumption Qhe

3625 kWh

4975 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

125 %

COP

3.06

Heating up time

2:41 h:min

Standby power input

25.3 W

Reference hot water temperature

44.6 °C

Mixed water at 40°C

227.9 l

ERGA08EVH / EHSX(B)08P50E
Configure model
Model name
ERGA08EVH / EHSX(B)08P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.63 kW

2.78 kW

COP

4.6

2.7

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.4 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc Tj = 20 °C

1

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

131 %

Prated

8 kW

8 kW

SCOP

4.61

3.35

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7 kW

6.9 kW

COP Tj = -7°C

2.77

1.96

Cdh Tj = -7 °C

n/a

1

Pdh Tj = +2°C

4.2 kW

4.4 kW

COP Tj = +2°C

4.35

3.2

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

3.3 kW

3.3 kW

COP Tj = +7°C

6.49

4.64

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.9 kW

4.1 kW

COP Tj = 12°C

8.52

6.22

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

7.5 kW

COP Tj = Tbiv

2.66

1.9

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.1 kW

0.94 kW

Annual energy consumption Qhe

3588 kWh

4939 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

125 %

COP

3.06

Heating up time

2:41 h:min

Standby power input

25.3 W

Reference hot water temperature

44.6 °C

Mixed water at 40°C

227.9 l

ERGA08EVH7 / EHSH(B)08P50E
Configure model
Model name
ERGA08EVH7 / EHSH(B)08P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.63 kW

2.78 kW

COP

4.6

2.7

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.16 kW

Cooling capacity

6.25

EER

5.4

EN 14825

+7°C/+12°C

Pdesignc

5.4 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc Tj = 20 °C

1

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

130 %

Prated

8 kW

8 kW

SCOP

4.56

3.32

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7 kW

6.9 kW

COP Tj = -7°C

2.77

1.96

Cdh Tj = -7 °C

n/a

1

Pdh Tj = +2°C

4.2 kW

4.4 kW

COP Tj = +2°C

4.35

3.2

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

3.3 kW

3.3 kW

COP Tj = +7°C

6.49

4.64

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.9 kW

4.1 kW

COP Tj = 12°C

8.52

6.22

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

7.5 kW

COP Tj = Tbiv

2.66

1.9

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.1 kW

0.94 kW

Annual energy consumption Qhe

3625 kWh

4975 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

125 %

COP

3.06

Heating up time

2:41 h:min

Standby power input

25.3 W

Reference hot water temperature

44.6 °C

Mixed water at 40°C

227.9 l

ERGA08EVH7 / EHSX(B)08P50E
Configure model
Model name
ERGA08EVH7 / EHSX(B)08P50E
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.5 kW

7.5 kW

El input

1.63 kW

2.78 kW

COP

4.6

2.7

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.4 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc Tj = 20 °C

1

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

131 %

Prated

8 kW

8 kW

SCOP

4.61

3.35

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7 kW

6.9 kW

COP Tj = -7°C

2.77

1.96

Cdh Tj = -7 °C

n/a

1

Pdh Tj = +2°C

4.2 kW

4.4 kW

COP Tj = +2°C

4.35

3.2

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

3.3 kW

3.3 kW

COP Tj = +7°C

6.49

4.64

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

3.9 kW

4.1 kW

COP Tj = 12°C

8.52

6.22

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

7.5 kW

7.5 kW

COP Tj = Tbiv

2.66

1.9

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.9 kW

7.1 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.1 kW

0.94 kW

Annual energy consumption Qhe

3588 kWh

4939 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

125 %

COP

3.06

Heating up time

2:41 h:min

Standby power input

25.3 W

Reference hot water temperature

44.6 °C

Mixed water at 40°C

227.9 l