Certificate holders

Subtype

Samsung EHS LNHT 12/14kW (space heating)

Certificate Holder
Samsung Electronics Air Conditioner Europe B.V.
Evert van de Beekstraat 310
1118 CX Schiphol
Netherlands
Registration number
011-1W0550
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Samsung EHS LNHT 12/14kW (space heating)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

3,300 kg

Certification Date
27.09.2022
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 10 (as of 2022-06)
Generate PDF Export model CSV
  • Number of models 8

Models

AE120BXYDEG/EU & MIM-E03EN
Configure model
Model name
AE120BXYDEG/EU & MIM-E03EN
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.35 kW

3.53 kW

COP

5.11

3.40

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

148 %

Prated

12.60 kW

12.60 kW

SCOP

4.90

3.78

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.15 kW

11.15 kW

COP Tj = -7°C

3.10

2.30

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.80 kW

6.80 kW

COP Tj = +2°C

4.70

3.70

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.70 kW

4.70 kW

COP Tj = +7°C

6.60

5.00

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.70 kW

4.70 kW

COP Tj = 12°C

8.60

6.30

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.15 kW

11.15 kW

COP Tj = Tbiv

3.10

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.30 kW

12.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.30 kW

Annual energy consumption Qhe

5277 kWh

6862 kWh

AE120BXYDEG/EU & MIM-E03CN
Configure model
Model name
AE120BXYDEG/EU & MIM-E03CN
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.35 kW

3.53 kW

COP

5.11

3.40

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

148 %

Prated

12.60 kW

12.60 kW

SCOP

4.90

3.78

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.15 kW

11.15 kW

COP Tj = -7°C

3.10

2.30

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.80 kW

6.80 kW

COP Tj = +2°C

4.70

3.70

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.70 kW

4.70 kW

COP Tj = +7°C

6.60

5.00

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.70 kW

4.70 kW

COP Tj = 12°C

8.60

6.30

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.15 kW

11.15 kW

COP Tj = Tbiv

3.10

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.30 kW

12.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Gas

Supplementary Heater: PSUP

0.30 kW

0.30 kW

Annual energy consumption Qhe

5277 kWh

6862 kWh

AE120BXYDGG/EU & MIM-E03EN
Configure model
Model name
AE120BXYDGG/EU & MIM-E03EN
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.35 kW

3.53 kW

COP

5.11

3.40

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

148 %

Prated

12.60 kW

12.60 kW

SCOP

4.90

3.78

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.15 kW

11.15 kW

COP Tj = -7°C

3.10

2.30

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.80 kW

6.80 kW

COP Tj = +2°C

4.70

3.70

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.70 kW

4.70 kW

COP Tj = +7°C

6.60

5.00

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.70 kW

4.70 kW

COP Tj = 12°C

8.60

6.30

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.15 kW

11.15 kW

COP Tj = Tbiv

3.10

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.30 kW

12.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.30 kW

Annual energy consumption Qhe

5277 kWh

6862 kWh

AE120BXYDGG/EU & MIM-E03CN
Configure model
Model name
AE120BXYDGG/EU & MIM-E03CN
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.35 kW

3.53 kW

COP

5.11

3.40

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

148 %

Prated

12.60 kW

12.60 kW

SCOP

4.90

3.78

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.15 kW

11.15 kW

COP Tj = -7°C

3.10

2.30

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.80 kW

6.80 kW

COP Tj = +2°C

4.70

3.70

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.70 kW

4.70 kW

COP Tj = +7°C

6.60

5.00

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.70 kW

4.70 kW

COP Tj = 12°C

8.60

6.30

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.15 kW

11.15 kW

COP Tj = Tbiv

3.10

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.30 kW

12.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.899

0.900

WTOL

70 °C

70 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.30 kW

Annual energy consumption Qhe

5277 kWh

6862 kWh

AE140BXYDEG/EU & MIM-E03EN
Configure model
Model name
AE140BXYDEG/EU & MIM-E03EN
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.77 kW

4.18 kW

COP

5.05

3.35

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

147 %

Prated

13.60 kW

13.60 kW

SCOP

4.83

3.75

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.03 kW

12.03 kW

COP Tj = -7°C

2.90

2.28

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.32 kW

7.32 kW

COP Tj = +2°C

4.65

3.65

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.80 kW

4.80 kW

COP Tj = +7°C

6.60

5.00

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.80 kW

4.80 kW

COP Tj = 12°C

8.60

6.28

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.03 kW

12.03 kW

COP Tj = Tbiv

2.90

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.30 kW

13.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.30 kW

Annual energy consumption Qhe

5796 kWh

7472 kWh

AE140BXYDEG/EU & MIM-E03CN
Configure model
Model name
AE140BXYDEG/EU & MIM-E03CN
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.77 kW

4.18 kW

COP

5.05

3.35

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

147 %

Prated

13.60 kW

13.60 kW

SCOP

4.83

3.75

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.03 kW

12.03 kW

COP Tj = -7°C

2.90

2.28

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.32 kW

7.32 kW

COP Tj = +2°C

4.65

3.65

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.80 kW

4.80 kW

COP Tj = +7°C

6.60

5.00

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.80 kW

4.80 kW

COP Tj = 12°C

8.60

6.28

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.03 kW

12.03 kW

COP Tj = Tbiv

2.90

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.30 kW

13.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.30 kW

Annual energy consumption Qhe

5796 kWh

7472 kWh

AE140BXYDGG/EU & MIM-E03EN
Configure model
Model name
AE140BXYDGG/EU & MIM-E03EN
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.77 kW

4.18 kW

COP

5.05

3.35

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

147 %

Prated

13.60 kW

13.60 kW

SCOP

4.83

3.75

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.03 kW

12.03 kW

COP Tj = -7°C

2.90

2.28

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.32 kW

7.32 kW

COP Tj = +2°C

4.65

3.65

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.80 kW

4.80 kW

COP Tj = +7°C

6.60

5.00

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.80 kW

4.80 kW

COP Tj = 12°C

8.60

6.28

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.03 kW

12.03 kW

COP Tj = Tbiv

2.90

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.30 kW

13.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.30 kW

Annual energy consumption Qhe

5796 kWh

7472 kWh

AE140BXYDGG/EU & MIM-E03CN
Configure model
Model name
AE140BXYDGG/EU & MIM-E03CN
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.77 kW

4.18 kW

COP

5.05

3.35

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

147 %

Prated

13.60 kW

13.60 kW

SCOP

4.83

3.75

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.03 kW

12.00 kW

COP Tj = -7°C

2.90

2.28

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.32 kW

7.30 kW

COP Tj = +2°C

4.65

3.65

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.80 kW

4.80 kW

COP Tj = +7°C

6.60

5.00

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.80 kW

4.80 kW

COP Tj = 12°C

8.60

6.28

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.03 kW

12.00 kW

COP Tj = Tbiv

2.90

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.30 kW

13.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.30 kW

Annual energy consumption Qhe

5796 kWh

7472 kWh