3,300 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.67 kW
4.39 kW
El input
0.93 kW
1.62 kW
COP
5.00
2.71
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
163 %
Prated
10.87 kW
11.43 kW
SCOP
6.29
4.15
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.87 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.30 kW
7.90 kW
COP Tj = +7°C
5.37
3.45
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
10.87 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.87 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2308 kWh
3681 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
148 %
113 %
Prated
9.05 kW
9.15 kW
SCOP
3.78
2.90
Tbiv
-17 °C
-16 °C
TOL
-18 °C
-17 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Pdh Tj = +2°C
5.40 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Pdh Tj = +7°C
2.77 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
5.90
Pdh Tj = Tbiv
7.39 kW
7.71 kW
COP Tj = Tbiv
2.11
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.18 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.05 kW
9.15 kW
Annual energy consumption Qhe
5895 kWh
7769 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.80
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.14 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.54 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4558 kWh
5389 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
102 %
COP
2.35
Heating up time
01:51 h:min
Standby power input
69.0 W
Reference hot water temperature
51.3 °C
Mixed water at 40°C
252 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
75 %
COP
1.73
Heating up time
02:37 h:min
Standby power input
94.0 W
Reference hot water temperature
51.3 °C
Mixed water at 40°C
257 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
91 %
COP
2.11
Heating up time
02:15 h:min
Standby power input
71.0 W
Reference hot water temperature
52.2 °C
Mixed water at 40°C
255 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.67 kW
4.39 kW
El input
0.93 kW
1.62 kW
COP
5.00
2.71
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
163 %
Prated
10.87 kW
11.43 kW
SCOP
6.29
4.15
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.87 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.30 kW
7.90 kW
COP Tj = +7°C
5.37
3.45
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
10.87 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.87 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2308 kWh
3681 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
148 %
113 %
Prated
9.05 kW
9.15 kW
SCOP
3.78
2.90
Tbiv
-17 °C
-16 °C
TOL
-18 °C
-17 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Pdh Tj = +2°C
5.40 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Pdh Tj = +7°C
2.77 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
5.90
Pdh Tj = Tbiv
7.39 kW
7.71 kW
COP Tj = Tbiv
2.11
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.18 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.05 kW
9.15 kW
Annual energy consumption Qhe
5895 kWh
7769 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.80
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.14 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.54 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4558 kWh
5389 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
111 %
COP
2.55
Heating up time
01:49 h:min
Standby power input
66.0 W
Reference hot water temperature
52.7 °C
Mixed water at 40°C
266 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
76 %
COP
1.77
Heating up time
02:34 h:min
Standby power input
83.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
269 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
92 %
COP
2.15
Heating up time
02:12 h:min
Standby power input
68.0 W
Reference hot water temperature
53.2 °C
Mixed water at 40°C
265 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.67 kW
4.39 kW
El input
0.93 kW
1.62 kW
COP
5.00
2.71
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
163 %
Prated
10.87 kW
11.43 kW
SCOP
6.29
4.15
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.87 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.30 kW
7.90 kW
COP Tj = +7°C
5.37
3.45
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
10.87 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.87 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2308 kWh
3681 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
148 %
113 %
Prated
9.05 kW
9.15 kW
SCOP
3.78
2.90
Tbiv
-17 °C
-16 °C
TOL
-18 °C
-17 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Cdh Tj = -7 °C
Pdh Tj = +2°C
5.40 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Cdh Tj = +2 °C
Pdh Tj = +7°C
2.77 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
5.90
Cdh Tj = +12 °C
Pdh Tj = Tbiv
7.39 kW
7.71 kW
COP Tj = Tbiv
2.11
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.18 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
9.05 kW
9.15 kW
Annual energy consumption Qhe
5895 kWh
7769 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.80
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.14 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.54 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4558 kWh
5389 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.67 kW
4.39 kW
El input
0.93 kW
1.62 kW
COP
5.00
2.71
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
163 %
Prated
10.87 kW
11.43 kW
SCOP
6.29
4.15
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.87 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.30 kW
7.90 kW
COP Tj = +7°C
5.37
3.45
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
10.87 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.87 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2308 kWh
3681 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
148 %
113 %
Prated
9.05 kW
9.15 kW
SCOP
3.78
2.90
Tbiv
-17 °C
-16 °C
TOL
-18 °C
-17 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Pdh Tj = +2°C
5.40 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Pdh Tj = +7°C
2.77 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
5.90
Pdh Tj = Tbiv
7.39 kW
7.71 kW
COP Tj = Tbiv
2.11
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.18 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.05 kW
9.15 kW
Annual energy consumption Qhe
5895 kWh
7769 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.80
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.14 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.54 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4558 kWh
5389 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.19 kW
4.62 kW
El input
1.04 kW
1.62 kW
COP
4.98
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
167 %
Prated
11.80 kW
11.43 kW
SCOP
6.30
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.80 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.62 kW
7.90 kW
COP Tj = +7°C
5.37
3.61
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
11.80 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.80 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2504 kWh
3603 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
114 %
Prated
9.49 kW
8.87 kW
SCOP
3.87
2.93
Tbiv
-17 °C
-17 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Pdh Tj = +2°C
7.25 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Pdh Tj = +7°C
5.48 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
6.14
Pdh Tj = Tbiv
8.25 kW
7.71 kW
COP Tj = Tbiv
2.36
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.48 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.49 kW
8.87 kW
Annual energy consumption Qhe
6039 kWh
7456 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.25
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.53 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.68 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4562 kWh
5389 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
102 %
COP
2.35
Heating up time
01:51 h:min
Standby power input
69.0 W
Reference hot water temperature
51.3 °C
Mixed water at 40°C
252 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
75 %
COP
1.73
Heating up time
02:37 h:min
Standby power input
94.0 W
Reference hot water temperature
51.3 °C
Mixed water at 40°C
257 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
91 %
COP
2.11
Heating up time
02:15 h:min
Standby power input
71.0 W
Reference hot water temperature
52.2 °C
Mixed water at 40°C
255 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.19 kW
4.62 kW
El input
1.04 kW
1.62 kW
COP
4.98
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
167 %
Prated
11.80 kW
11.43 kW
SCOP
6.30
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.80 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.62 kW
7.90 kW
COP Tj = +7°C
5.37
3.61
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
11.80 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.80 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2504 kWh
3603 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
114 %
Prated
9.49 kW
8.87 kW
SCOP
3.87
2.93
Tbiv
-17 °C
-17 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Pdh Tj = +2°C
7.25 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Pdh Tj = +7°C
5.48 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
6.14
Pdh Tj = Tbiv
8.25 kW
7.71 kW
COP Tj = Tbiv
2.36
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.48 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.49 kW
8.87 kW
Annual energy consumption Qhe
6039 kWh
7456 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.25
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.53 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.68 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4562 kWh
5389 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
111 %
COP
2.55
Heating up time
01:48 h:min
Standby power input
66.0 W
Reference hot water temperature
52.7 °C
Mixed water at 40°C
266 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
76 %
COP
1.77
Heating up time
02:34 h:min
Standby power input
83.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
269 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
92 %
COP
2.15
Heating up time
02:12 h:min
Standby power input
68.0 W
Reference hot water temperature
53.2 °C
Mixed water at 40°C
265 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.19 kW
4.62 kW
El input
1.04 kW
1.62 kW
COP
4.98
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
167 %
Prated
11.80 kW
11.43 kW
SCOP
6.30
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.80 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.62 kW
7.90 kW
COP Tj = +7°C
5.37
3.61
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
11.80 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.80 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2504 kWh
3603 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
114 %
Prated
9.49 kW
8.87 kW
SCOP
3.87
2.93
Tbiv
-17 °C
-17 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Cdh Tj = -7 °C
Pdh Tj = +2°C
7.25 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Cdh Tj = +2 °C
Pdh Tj = +7°C
5.48 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
6.14
Cdh Tj = +12 °C
Pdh Tj = Tbiv
8.25 kW
7.71 kW
COP Tj = Tbiv
2.36
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.48 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
9.49 kW
8.87 kW
Annual energy consumption Qhe
6039 kWh
7456 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.25
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.53 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.68 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4562 kWh
5389 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.19 kW
4.62 kW
El input
1.04 kW
1.62 kW
COP
4.98
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
167 %
Prated
11.80 kW
11.43 kW
SCOP
6.30
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.80 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.62 kW
7.90 kW
COP Tj = +7°C
5.37
3.61
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
11.80 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.80 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2504 kWh
3603 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
114 %
Prated
9.49 kW
8.87 kW
SCOP
3.87
2.93
Tbiv
-17 °C
-17 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Pdh Tj = +2°C
7.25 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Pdh Tj = +7°C
5.48 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
6.14
Pdh Tj = Tbiv
8.25 kW
7.71 kW
COP Tj = Tbiv
2.36
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.48 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.49 kW
8.87 kW
Annual energy consumption Qhe
6039 kWh
7456 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.25
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.53 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.68 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4562 kWh
5389 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.86 kW
4.60 kW
El input
1.47 kW
1.79 kW
COP
4.68
2.56
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
166 %
Prated
12.10 kW
10.00 kW
SCOP
5.78
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.20 kW
10.02 kW
COP Tj = +2°C
2.73
2.18
Pdh Tj = +7°C
7.77 kW
6.46 kW
COP Tj = +7°C
4.99
3.73
Pdh Tj = 12°C
3.46 kW
6.17 kW
COP Tj = 12°C
7.51
5.41
Pdh Tj = Tbiv
12.20 kW
10.02 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.20 kW
10.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
2.18
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2796 kWh
3154 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
121 %
Prated
9.80 kW
10.60 kW
SCOP
4.19
3.11
Tbiv
-17 °C
-15 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
6.24 kW
6.49 kW
COP Tj = -7°C
3.56
2.65
Pdh Tj = +2°C
3.66 kW
4.49 kW
COP Tj = +2°C
5.14
3.88
Pdh Tj = +7°C
2.82 kW
5.35 kW
COP Tj = +7°C
6.30
4.87
Pdh Tj = 12°C
3.06 kW
6.32 kW
COP Tj = 12°C
6.86
6.09
Pdh Tj = Tbiv
8.60 kW
8.70 kW
COP Tj = Tbiv
2.24
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.80 kW
8.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.80 kW
10.60 kW
Annual energy consumption Qhe
5762 kWh
8402 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.38
1.83
COP Tj = -15°C (if TOL<-20°C)
2.44
1.83
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
139 %
Prated
10.40 kW
8.60 kW
SCOP
4.73
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.07 kW
7.72 kW
COP Tj = -7°C
2.88
2.28
Pdh Tj = +2°C
5.93 kW
4.45 kW
COP Tj = +2°C
4.65
3.53
Pdh Tj = +7°C
3.75 kW
5.21 kW
COP Tj = +7°C
6.29
4.41
Pdh Tj = 12°C
3.11 kW
6.23 kW
COP Tj = 12°C
7.25
5.75
Pdh Tj = Tbiv
10.45 kW
8.59 kW
COP Tj = Tbiv
2.51
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.45 kW
8.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4540 kWh
5008 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
100 %
COP
2.32
Heating up time
01:48 h:min
Standby power input
57.0 W
Reference hot water temperature
51.6 °C
Mixed water at 40°C
253 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
80 %
COP
1.87
Heating up time
02:43 h:min
Standby power input
84.0 W
Reference hot water temperature
52.3 °C
Mixed water at 40°C
258 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
89 %
COP
2.09
Heating up time
02:21 h:min
Standby power input
63.0 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
256 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.86 kW
4.60 kW
El input
1.47 kW
1.79 kW
COP
4.68
2.56
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
166 %
Prated
12.10 kW
10.00 kW
SCOP
5.78
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.20 kW
10.02 kW
COP Tj = +2°C
2.73
2.18
Pdh Tj = +7°C
7.77 kW
6.46 kW
COP Tj = +7°C
4.99
3.73
Pdh Tj = 12°C
3.46 kW
6.17 kW
COP Tj = 12°C
7.51
5.41
Pdh Tj = Tbiv
12.20 kW
10.02 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.20 kW
10.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
2.18
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2796 kWh
3154 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
121 %
Prated
9.80 kW
10.60 kW
SCOP
4.19
3.11
Tbiv
-17 °C
-15 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
6.24 kW
6.49 kW
COP Tj = -7°C
3.56
2.65
Pdh Tj = +2°C
3.66 kW
4.49 kW
COP Tj = +2°C
5.14
3.88
Pdh Tj = +7°C
2.82 kW
5.35 kW
COP Tj = +7°C
6.30
4.87
Pdh Tj = 12°C
3.06 kW
6.32 kW
COP Tj = 12°C
6.86
6.09
Pdh Tj = Tbiv
8.60 kW
8.70 kW
COP Tj = Tbiv
2.24
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.80 kW
8.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.80 kW
10.60 kW
Annual energy consumption Qhe
5762 kWh
8402 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.38
1.83
COP Tj = -15°C (if TOL<-20°C)
2.44
1.83
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
139 %
Prated
10.40 kW
8.60 kW
SCOP
4.73
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.07 kW
7.72 kW
COP Tj = -7°C
2.88
2.28
Pdh Tj = +2°C
5.93 kW
4.45 kW
COP Tj = +2°C
4.65
3.53
Pdh Tj = +7°C
3.75 kW
5.21 kW
COP Tj = +7°C
6.29
4.41
Pdh Tj = 12°C
3.11 kW
6.23 kW
COP Tj = 12°C
7.25
5.75
Pdh Tj = Tbiv
10.45 kW
8.59 kW
COP Tj = Tbiv
2.51
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.45 kW
8.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4540 kWh
5008 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
108 %
COP
2.52
Heating up time
01:46 h:min
Standby power input
55.0 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
267 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
82 %
COP
1.91
Heating up time
02:41 h:min
Standby power input
74.0 W
Reference hot water temperature
53.5 °C
Mixed water at 40°C
270 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
91 %
COP
2.13
Heating up time
02:18 h:min
Standby power input
60.0 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
266 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.86 kW
4.60 kW
El input
1.47 kW
1.79 kW
COP
4.68
2.56
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
166 %
Prated
12.10 kW
10.00 kW
SCOP
5.78
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.20 kW
10.02 kW
COP Tj = +2°C
2.73
2.18
Pdh Tj = +7°C
7.77 kW
6.46 kW
COP Tj = +7°C
4.99
3.73
Pdh Tj = 12°C
3.46 kW
6.17 kW
COP Tj = 12°C
7.51
5.41
Pdh Tj = Tbiv
12.20 kW
10.02 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.20 kW
10.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
2.18
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2796 kWh
3154 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
121 %
Prated
9.80 kW
10.60 kW
SCOP
4.19
3.11
Tbiv
-17 °C
-15 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
6.24 kW
6.49 kW
COP Tj = -7°C
3.56
2.65
Cdh Tj = -7 °C
Pdh Tj = +2°C
3.66 kW
4.49 kW
COP Tj = +2°C
5.14
3.88
Cdh Tj = +2 °C
Pdh Tj = +7°C
2.82 kW
5.35 kW
COP Tj = +7°C
6.30
4.87
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.06 kW
6.32 kW
COP Tj = 12°C
6.86
6.09
Cdh Tj = +12 °C
Pdh Tj = Tbiv
8.60 kW
8.70 kW
COP Tj = Tbiv
2.24
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.80 kW
8.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
9.80 kW
10.60 kW
Annual energy consumption Qhe
5762 kWh
8402 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.38
1.83
COP Tj = -15°C (if TOL<-20°C)
2.44
1.83
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
139 %
Prated
10.40 kW
8.60 kW
SCOP
4.73
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.07 kW
7.72 kW
COP Tj = -7°C
2.88
2.28
Pdh Tj = +2°C
5.93 kW
4.45 kW
COP Tj = +2°C
4.65
3.53
Pdh Tj = +7°C
3.75 kW
5.21 kW
COP Tj = +7°C
6.29
4.41
Pdh Tj = 12°C
3.11 kW
6.23 kW
COP Tj = 12°C
7.25
5.75
Pdh Tj = Tbiv
10.45 kW
8.59 kW
COP Tj = Tbiv
2.51
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.45 kW
8.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4540 kWh
5008 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.86 kW
4.60 kW
El input
1.47 kW
1.79 kW
COP
4.68
2.56
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
166 %
Prated
12.10 kW
10.00 kW
SCOP
5.78
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.20 kW
10.02 kW
COP Tj = +2°C
2.73
2.18
Pdh Tj = +7°C
7.77 kW
6.46 kW
COP Tj = +7°C
4.99
3.73
Pdh Tj = 12°C
3.46 kW
6.17 kW
COP Tj = 12°C
7.51
5.41
Pdh Tj = Tbiv
12.20 kW
10.02 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.20 kW
10.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
2.18
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2796 kWh
3154 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
121 %
Prated
9.80 kW
10.60 kW
SCOP
4.19
3.11
Tbiv
-17 °C
-15 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
6.24 kW
6.49 kW
COP Tj = -7°C
3.56
2.65
Pdh Tj = +2°C
3.66 kW
4.49 kW
COP Tj = +2°C
5.14
3.88
Pdh Tj = +7°C
2.82 kW
5.35 kW
COP Tj = +7°C
6.30
4.87
Pdh Tj = 12°C
3.06 kW
6.32 kW
COP Tj = 12°C
6.86
6.09
Pdh Tj = Tbiv
8.60 kW
8.70 kW
COP Tj = Tbiv
2.24
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.80 kW
8.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.80 kW
10.60 kW
Annual energy consumption Qhe
5762 kWh
8402 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.38
1.83
COP Tj = -15°C (if TOL<-20°C)
2.44
1.83
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
139 %
Prated
10.40 kW
8.60 kW
SCOP
4.73
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.07 kW
7.72 kW
COP Tj = -7°C
2.88
2.28
Pdh Tj = +2°C
5.93 kW
4.45 kW
COP Tj = +2°C
4.65
3.53
Pdh Tj = +7°C
3.75 kW
5.21 kW
COP Tj = +7°C
6.29
4.41
Pdh Tj = 12°C
3.11 kW
6.23 kW
COP Tj = 12°C
7.25
5.75
Pdh Tj = Tbiv
10.45 kW
8.59 kW
COP Tj = Tbiv
2.51
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.45 kW
8.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4540 kWh
5008 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.19 kW
4.62 kW
El input
1.04 kW
1.62 kW
COP
4.98
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
167 %
Prated
11.80 kW
11.43 kW
SCOP
6.30
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.80 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.62 kW
7.90 kW
COP Tj = +7°C
5.37
3.61
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
11.80 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.80 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2504 kWh
3603 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
114 %
Prated
9.49 kW
8.87 kW
SCOP
3.87
2.93
Tbiv
-17 °C
-17 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Cdh Tj = -7 °C
Pdh Tj = +2°C
7.25 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Cdh Tj = +2 °C
Pdh Tj = +7°C
5.48 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
6.14
Cdh Tj = +12 °C
Pdh Tj = Tbiv
8.25 kW
7.71 kW
COP Tj = Tbiv
2.36
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.48 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
9.49 kW
8.87 kW
Annual energy consumption Qhe
6039 kWh
7456 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.25
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.53 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.68 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4562 kWh
5389 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.19 kW
4.62 kW
El input
1.04 kW
1.62 kW
COP
4.98
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
167 %
Prated
11.80 kW
11.43 kW
SCOP
6.30
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.80 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.62 kW
7.90 kW
COP Tj = +7°C
5.37
3.61
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
11.80 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.80 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2504 kWh
3603 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
114 %
Prated
9.49 kW
8.87 kW
SCOP
3.87
2.93
Tbiv
-17 °C
-17 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Pdh Tj = +2°C
7.25 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Pdh Tj = +7°C
5.48 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
6.14
Pdh Tj = Tbiv
8.25 kW
7.71 kW
COP Tj = Tbiv
2.36
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.48 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.49 kW
8.87 kW
Annual energy consumption Qhe
6039 kWh
7456 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.25
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.53 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.68 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4562 kWh
5389 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
111 %
COP
2.55
Heating up time
01:48 h:min
Standby power input
66.0 W
Reference hot water temperature
52.7 °C
Mixed water at 40°C
266 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
76 %
COP
1.77
Heating up time
02:34 h:min
Standby power input
83.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
269 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
92 %
COP
2.15
Heating up time
02:12 h:min
Standby power input
68.0 W
Reference hot water temperature
53.2 °C
Mixed water at 40°C
265 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.19 kW
4.62 kW
El input
1.04 kW
1.62 kW
COP
4.98
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
167 %
Prated
11.80 kW
11.43 kW
SCOP
6.30
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.80 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.62 kW
7.90 kW
COP Tj = +7°C
5.37
3.61
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
11.80 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.80 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2504 kWh
3603 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
114 %
Prated
9.49 kW
8.87 kW
SCOP
3.87
2.93
Tbiv
-17 °C
-17 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Pdh Tj = +2°C
7.25 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Pdh Tj = +7°C
5.48 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
6.14
Pdh Tj = Tbiv
8.25 kW
7.71 kW
COP Tj = Tbiv
2.36
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.48 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.49 kW
8.87 kW
Annual energy consumption Qhe
6039 kWh
7456 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.25
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.53 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.68 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4562 kWh
5389 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.19 kW
4.62 kW
El input
1.04 kW
1.62 kW
COP
4.98
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
167 %
Prated
11.80 kW
11.43 kW
SCOP
6.30
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.80 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.62 kW
7.90 kW
COP Tj = +7°C
5.37
3.61
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
11.80 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.80 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2504 kWh
3603 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
114 %
Prated
9.49 kW
8.87 kW
SCOP
3.87
2.93
Tbiv
-17 °C
-17 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Pdh Tj = +2°C
7.25 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Pdh Tj = +7°C
5.48 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
6.14
Pdh Tj = Tbiv
8.25 kW
7.71 kW
COP Tj = Tbiv
2.36
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.48 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.49 kW
8.87 kW
Annual energy consumption Qhe
6039 kWh
7456 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.25
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.53 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.68 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4562 kWh
5389 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
102 %
COP
2.35
Heating up time
01:51 h:min
Standby power input
69.0 W
Reference hot water temperature
51.3 °C
Mixed water at 40°C
252 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
75 %
COP
1.73
Heating up time
02:37 h:min
Standby power input
94.0 W
Reference hot water temperature
51.3 °C
Mixed water at 40°C
257 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
91 %
COP
2.11
Heating up time
02:15 h:min
Standby power input
71.0 W
Reference hot water temperature
52.2 °C
Mixed water at 40°C
255 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.86 kW
4.60 kW
El input
1.47 kW
1.79 kW
COP
4.68
2.56
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
166 %
Prated
12.10 kW
10.00 kW
SCOP
5.78
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.20 kW
10.02 kW
COP Tj = +2°C
2.73
2.18
Pdh Tj = +7°C
7.77 kW
6.46 kW
COP Tj = +7°C
4.99
3.73
Pdh Tj = 12°C
3.46 kW
6.17 kW
COP Tj = 12°C
7.51
5.41
Pdh Tj = Tbiv
12.20 kW
10.02 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.20 kW
10.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
2.18
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2796 kWh
3154 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
121 %
Prated
9.80 kW
10.60 kW
SCOP
4.19
3.11
Tbiv
-17 °C
-15 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
6.24 kW
6.49 kW
COP Tj = -7°C
3.56
2.65
Cdh Tj = -7 °C
Pdh Tj = +2°C
3.66 kW
4.49 kW
COP Tj = +2°C
5.14
3.88
Cdh Tj = +2 °C
Pdh Tj = +7°C
2.82 kW
5.35 kW
COP Tj = +7°C
6.30
4.87
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.06 kW
6.32 kW
COP Tj = 12°C
6.86
6.09
Cdh Tj = +12 °C
Pdh Tj = Tbiv
8.60 kW
8.70 kW
COP Tj = Tbiv
2.24
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.80 kW
8.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
9.80 kW
10.60 kW
Annual energy consumption Qhe
5762 kWh
8402 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.38
1.83
COP Tj = -15°C (if TOL<-20°C)
2.44
1.83
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
139 %
Prated
10.40 kW
8.60 kW
SCOP
4.73
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.07 kW
7.72 kW
COP Tj = -7°C
2.88
2.28
Pdh Tj = +2°C
5.93 kW
4.45 kW
COP Tj = +2°C
4.65
3.53
Pdh Tj = +7°C
3.75 kW
5.21 kW
COP Tj = +7°C
6.29
4.41
Pdh Tj = 12°C
3.11 kW
6.23 kW
COP Tj = 12°C
7.25
5.75
Pdh Tj = Tbiv
10.45 kW
8.59 kW
COP Tj = Tbiv
2.51
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.45 kW
8.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4540 kWh
5008 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.86 kW
4.60 kW
El input
1.47 kW
1.79 kW
COP
4.68
2.56
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
166 %
Prated
12.10 kW
10.00 kW
SCOP
5.78
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.20 kW
10.02 kW
COP Tj = +2°C
2.73
2.18
Pdh Tj = +7°C
7.77 kW
6.46 kW
COP Tj = +7°C
4.99
3.73
Pdh Tj = 12°C
3.46 kW
6.17 kW
COP Tj = 12°C
7.51
5.41
Pdh Tj = Tbiv
12.20 kW
10.02 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.20 kW
10.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
2.18
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2796 kWh
3154 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
121 %
Prated
9.80 kW
10.60 kW
SCOP
4.19
3.11
Tbiv
-17 °C
-15 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
6.24 kW
6.49 kW
COP Tj = -7°C
3.56
2.65
Pdh Tj = +2°C
3.66 kW
4.49 kW
COP Tj = +2°C
5.14
3.88
Pdh Tj = +7°C
2.82 kW
5.35 kW
COP Tj = +7°C
6.30
4.87
Pdh Tj = 12°C
3.06 kW
6.32 kW
COP Tj = 12°C
6.86
6.09
Pdh Tj = Tbiv
8.60 kW
8.70 kW
COP Tj = Tbiv
2.24
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.80 kW
8.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.80 kW
10.60 kW
Annual energy consumption Qhe
5762 kWh
8402 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.38
1.83
COP Tj = -15°C (if TOL<-20°C)
2.44
1.83
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
139 %
Prated
10.40 kW
8.60 kW
SCOP
4.73
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.07 kW
7.72 kW
COP Tj = -7°C
2.88
2.28
Pdh Tj = +2°C
5.93 kW
4.45 kW
COP Tj = +2°C
4.65
3.53
Pdh Tj = +7°C
3.75 kW
5.21 kW
COP Tj = +7°C
6.29
4.41
Pdh Tj = 12°C
3.11 kW
6.23 kW
COP Tj = 12°C
7.25
5.75
Pdh Tj = Tbiv
10.45 kW
8.59 kW
COP Tj = Tbiv
2.51
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.45 kW
8.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4540 kWh
5008 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
108 %
COP
2.52
Heating up time
01:46 h:min
Standby power input
55.0 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
267 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
82 %
COP
1.91
Heating up time
02:41 h:min
Standby power input
74.0 W
Reference hot water temperature
53.5 °C
Mixed water at 40°C
270 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
91 %
COP
2.13
Heating up time
02:18 h:min
Standby power input
60.0 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
266 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.86 kW
4.60 kW
El input
1.47 kW
1.79 kW
COP
4.68
2.56
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
166 %
Prated
12.10 kW
10.00 kW
SCOP
5.78
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.20 kW
10.02 kW
COP Tj = +2°C
2.73
2.18
Pdh Tj = +7°C
7.77 kW
6.46 kW
COP Tj = +7°C
4.99
3.73
Pdh Tj = 12°C
3.46 kW
6.17 kW
COP Tj = 12°C
7.51
5.41
Pdh Tj = Tbiv
12.20 kW
10.02 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.20 kW
10.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
2.18
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2796 kWh
3154 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
121 %
Prated
9.80 kW
10.60 kW
SCOP
4.19
3.11
Tbiv
-17 °C
-15 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
6.24 kW
6.49 kW
COP Tj = -7°C
3.56
2.65
Pdh Tj = +2°C
3.66 kW
4.49 kW
COP Tj = +2°C
5.14
3.88
Pdh Tj = +7°C
2.82 kW
5.35 kW
COP Tj = +7°C
6.30
4.87
Pdh Tj = 12°C
3.06 kW
6.32 kW
COP Tj = 12°C
6.86
6.09
Pdh Tj = Tbiv
8.60 kW
8.70 kW
COP Tj = Tbiv
2.24
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.80 kW
8.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.80 kW
10.60 kW
Annual energy consumption Qhe
5762 kWh
8402 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.38
1.83
COP Tj = -15°C (if TOL<-20°C)
2.44
1.83
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
139 %
Prated
10.40 kW
8.60 kW
SCOP
4.73
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.07 kW
7.72 kW
COP Tj = -7°C
2.88
2.28
Pdh Tj = +2°C
5.93 kW
4.45 kW
COP Tj = +2°C
4.65
3.53
Pdh Tj = +7°C
3.75 kW
5.21 kW
COP Tj = +7°C
6.29
4.41
Pdh Tj = 12°C
3.11 kW
6.23 kW
COP Tj = 12°C
7.25
5.75
Pdh Tj = Tbiv
10.45 kW
8.59 kW
COP Tj = Tbiv
2.51
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.45 kW
8.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4540 kWh
5008 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
100 %
COP
2.32
Heating up time
01:48 h:min
Standby power input
57.0 W
Reference hot water temperature
51.6 °C
Mixed water at 40°C
253 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
80 %
COP
1.87
Heating up time
02:43 h:min
Standby power input
84.0 W
Reference hot water temperature
52.3 °C
Mixed water at 40°C
258 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
89 %
COP
2.09
Heating up time
02:21 h:min
Standby power input
63.0 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
256 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.86 kW
4.60 kW
El input
1.47 kW
1.79 kW
COP
4.68
2.56
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
166 %
Prated
12.10 kW
10.00 kW
SCOP
5.78
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.20 kW
10.02 kW
COP Tj = +2°C
2.73
2.18
Pdh Tj = +7°C
7.77 kW
6.46 kW
COP Tj = +7°C
4.99
3.73
Pdh Tj = 12°C
3.46 kW
6.17 kW
COP Tj = 12°C
7.51
5.41
Pdh Tj = Tbiv
12.20 kW
10.02 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.20 kW
10.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
2.18
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2796 kWh
3154 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
121 %
Prated
9.80 kW
10.60 kW
SCOP
4.19
3.11
Tbiv
-17 °C
-15 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
6.24 kW
6.49 kW
COP Tj = -7°C
3.56
2.65
Pdh Tj = +2°C
3.66 kW
4.49 kW
COP Tj = +2°C
5.14
3.88
Pdh Tj = +7°C
2.82 kW
5.35 kW
COP Tj = +7°C
6.30
4.87
Pdh Tj = 12°C
3.06 kW
6.32 kW
COP Tj = 12°C
6.86
6.09
Pdh Tj = Tbiv
8.60 kW
8.70 kW
COP Tj = Tbiv
2.24
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.80 kW
8.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.80 kW
10.60 kW
Annual energy consumption Qhe
5762 kWh
8402 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.38
1.83
COP Tj = -15°C (if TOL<-20°C)
2.44
1.83
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
139 %
Prated
10.40 kW
8.60 kW
SCOP
4.73
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.07 kW
7.72 kW
COP Tj = -7°C
2.88
2.28
Pdh Tj = +2°C
5.93 kW
4.45 kW
COP Tj = +2°C
4.65
3.53
Pdh Tj = +7°C
3.75 kW
5.21 kW
COP Tj = +7°C
6.29
4.41
Pdh Tj = 12°C
3.11 kW
6.23 kW
COP Tj = 12°C
7.25
5.75
Pdh Tj = Tbiv
10.45 kW
8.59 kW
COP Tj = Tbiv
2.51
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.45 kW
8.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4540 kWh
5008 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.19 kW
4.62 kW
El input
1.04 kW
1.62 kW
COP
4.98
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
167 %
Prated
11.80 kW
11.43 kW
SCOP
6.30
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.80 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.62 kW
7.90 kW
COP Tj = +7°C
5.37
3.61
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
11.80 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.80 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2504 kWh
3603 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
114 %
Prated
9.49 kW
8.87 kW
SCOP
3.87
2.93
Tbiv
-17 °C
-17 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Pdh Tj = +2°C
7.25 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Pdh Tj = +7°C
5.48 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
6.14
Pdh Tj = Tbiv
8.25 kW
7.71 kW
COP Tj = Tbiv
2.36
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.48 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.49 kW
8.87 kW
Annual energy consumption Qhe
6039 kWh
7456 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.25
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.53 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.68 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4562 kWh
5389 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
102 %
COP
2.35
Heating up time
01:51 h:min
Standby power input
69.0 W
Reference hot water temperature
51.3 °C
Mixed water at 40°C
252 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
75 %
COP
1.73
Heating up time
02:37 h:min
Standby power input
94.0 W
Reference hot water temperature
51.3 °C
Mixed water at 40°C
257 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
91 %
COP
2.11
Heating up time
02:15 h:min
Standby power input
71.0 W
Reference hot water temperature
52.2 °C
Mixed water at 40°C
255 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.19 kW
4.62 kW
El input
1.04 kW
1.62 kW
COP
4.98
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
167 %
Prated
11.80 kW
11.43 kW
SCOP
6.30
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.80 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.62 kW
7.90 kW
COP Tj = +7°C
5.37
3.61
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
11.80 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.80 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2504 kWh
3603 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
114 %
Prated
9.49 kW
8.87 kW
SCOP
3.87
2.93
Tbiv
-17 °C
-17 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Pdh Tj = +2°C
7.25 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Pdh Tj = +7°C
5.48 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
6.14
Pdh Tj = Tbiv
8.25 kW
7.71 kW
COP Tj = Tbiv
2.36
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.48 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.49 kW
8.87 kW
Annual energy consumption Qhe
6039 kWh
7456 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.25
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.53 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.68 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4562 kWh
5389 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
111 %
COP
2.55
Heating up time
01:48 h:min
Standby power input
66.0 W
Reference hot water temperature
52.7 °C
Mixed water at 40°C
266 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
76 %
COP
1.77
Heating up time
02:34 h:min
Standby power input
83.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
269 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
92 %
COP
2.15
Heating up time
02:12 h:min
Standby power input
68.0 W
Reference hot water temperature
53.2 °C
Mixed water at 40°C
265 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.19 kW
4.62 kW
El input
1.04 kW
1.62 kW
COP
4.98
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
167 %
Prated
11.80 kW
11.43 kW
SCOP
6.30
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.80 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.62 kW
7.90 kW
COP Tj = +7°C
5.37
3.61
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
11.80 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.80 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2504 kWh
3603 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
114 %
Prated
9.49 kW
8.87 kW
SCOP
3.87
2.93
Tbiv
-17 °C
-17 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Cdh Tj = -7 °C
Pdh Tj = +2°C
7.25 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Cdh Tj = +2 °C
Pdh Tj = +7°C
5.48 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
6.14
Cdh Tj = +12 °C
Pdh Tj = Tbiv
8.25 kW
7.71 kW
COP Tj = Tbiv
2.36
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.48 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
9.49 kW
8.87 kW
Annual energy consumption Qhe
6039 kWh
7456 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.25
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.53 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.68 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4562 kWh
5389 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.19 kW
4.62 kW
El input
1.04 kW
1.62 kW
COP
4.98
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
167 %
Prated
11.80 kW
11.43 kW
SCOP
6.30
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.80 kW
11.43 kW
COP Tj = +2°C
3.04
2.17
Pdh Tj = +7°C
7.62 kW
7.90 kW
COP Tj = +7°C
5.37
3.61
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
8.25
5.56
Pdh Tj = Tbiv
11.80 kW
11.43 kW
COP Tj = Tbiv
3.04
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.80 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.17
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2504 kWh
3603 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
114 %
Prated
9.49 kW
8.87 kW
SCOP
3.87
2.93
Tbiv
-17 °C
-17 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.61
2.70
Pdh Tj = +2°C
7.25 kW
6.86 kW
COP Tj = +2°C
4.12
3.23
Pdh Tj = +7°C
5.48 kW
5.19 kW
COP Tj = +7°C
6.35
4.86
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.59
6.14
Pdh Tj = Tbiv
8.25 kW
7.71 kW
COP Tj = Tbiv
2.36
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.48 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.49 kW
8.87 kW
Annual energy consumption Qhe
6039 kWh
7456 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.25
1.92
COP Tj = -15°C (if TOL<-20°C)
2.61
1.92
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
140 %
Prated
9.97 kW
9.33 kW
SCOP
4.52
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.53 kW
8.41 kW
COP Tj = -7°C
2.95
2.21
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
4.04
3.58
Pdh Tj = +7°C
3.68 kW
5.12 kW
COP Tj = +7°C
6.71
4.54
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.94
5.66
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4562 kWh
5389 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.86 kW
4.60 kW
El input
1.47 kW
1.79 kW
COP
4.68
2.56
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
166 %
Prated
12.10 kW
10.00 kW
SCOP
5.78
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.20 kW
10.02 kW
COP Tj = +2°C
2.73
2.18
Pdh Tj = +7°C
7.77 kW
6.46 kW
COP Tj = +7°C
4.99
3.73
Pdh Tj = 12°C
3.46 kW
6.17 kW
COP Tj = 12°C
7.51
5.41
Pdh Tj = Tbiv
12.20 kW
10.02 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.20 kW
10.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
2.18
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2796 kWh
3154 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
121 %
Prated
9.80 kW
10.60 kW
SCOP
4.19
3.11
Tbiv
-17 °C
-15 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
6.24 kW
6.49 kW
COP Tj = -7°C
3.56
2.65
Pdh Tj = +2°C
3.66 kW
4.49 kW
COP Tj = +2°C
5.14
3.88
Pdh Tj = +7°C
2.82 kW
5.35 kW
COP Tj = +7°C
6.30
4.87
Pdh Tj = 12°C
3.06 kW
6.32 kW
COP Tj = 12°C
6.86
6.09
Pdh Tj = Tbiv
8.60 kW
8.70 kW
COP Tj = Tbiv
2.24
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.80 kW
8.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.80 kW
10.60 kW
Annual energy consumption Qhe
5762 kWh
8402 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.38
1.83
COP Tj = -15°C (if TOL<-20°C)
2.44
1.83
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
139 %
Prated
10.40 kW
8.60 kW
SCOP
4.73
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.07 kW
7.72 kW
COP Tj = -7°C
2.88
2.28
Pdh Tj = +2°C
5.93 kW
4.45 kW
COP Tj = +2°C
4.65
3.53
Pdh Tj = +7°C
3.75 kW
5.21 kW
COP Tj = +7°C
6.29
4.41
Pdh Tj = 12°C
3.11 kW
6.23 kW
COP Tj = 12°C
7.25
5.75
Pdh Tj = Tbiv
10.45 kW
8.59 kW
COP Tj = Tbiv
2.51
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.45 kW
8.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.89
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4540 kWh
5008 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
108 %
COP
2.52
Heating up time
01:46 h:min
Standby power input
55.0 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
267 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
82 %
COP
1.91
Heating up time
02:41 h:min
Standby power input
74.0 W
Reference hot water temperature
53.5 °C
Mixed water at 40°C
270 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
91 %
COP
2.13
Heating up time
02:18 h:min
Standby power input
60.0 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
266 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.86 kW
4.60 kW
El input
1.47 kW
1.79 kW
COP
4.68
2.56
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
166 %
Prated
12.10 kW
10.00 kW
SCOP
5.78
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.20 kW
10.02 kW
COP Tj = +2°C
2.73
2.18
Pdh Tj = +7°C
7.77 kW
6.46 kW
COP Tj = +7°C
4.99
3.73
Pdh Tj = 12°C
3.46 kW
6.17 kW
COP Tj = 12°C
7.51
5.41
Pdh Tj = Tbiv
12.20 kW
10.02 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.20 kW
10.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
2.18
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2796 kWh
3154 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
121 %
Prated
9.80 kW
10.60 kW
SCOP
4.19
3.11
Tbiv
-17 °C
-15 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
6.24 kW
6.49 kW
COP Tj = -7°C
3.56
2.65
Pdh Tj = +2°C
3.66 kW
4.49 kW
COP Tj = +2°C
5.14
3.88
Pdh Tj = +7°C
2.82 kW
5.35 kW
COP Tj = +7°C
6.30
4.87
Pdh Tj = 12°C
3.06 kW
6.32 kW
COP Tj = 12°C
6.86
6.09
Pdh Tj = Tbiv
8.60 kW
8.70 kW
COP Tj = Tbiv
2.24
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.80 kW
8.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.80 kW
10.60 kW
Annual energy consumption Qhe
5762 kWh
8402 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.38
1.83
COP Tj = -15°C (if TOL<-20°C)
2.44
1.83
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
26 dB(A)
26 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
139 %
Prated
10.40 kW
8.60 kW
SCOP
4.73
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.07 kW
7.72 kW
COP Tj = -7°C
2.88
2.28
Pdh Tj = +2°C
5.93 kW
4.45 kW
COP Tj = +2°C
4.65
3.53
Pdh Tj = +7°C
3.75 kW
5.21 kW
COP Tj = +7°C
6.29
4.41
Pdh Tj = 12°C
3.11 kW
6.23 kW
COP Tj = 12°C
7.25
5.75
Pdh Tj = Tbiv
10.45 kW
8.59 kW
COP Tj = Tbiv
2.51
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.45 kW
8.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.89
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4540 kWh
5008 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
100 %
COP
2.32
Heating up time
01:48 h:min
Standby power input
57.0 W
Reference hot water temperature
51.6 °C
Mixed water at 40°C
253 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
80 %
COP
1.87
Heating up time
02:43 h:min
Standby power input
84.0 W
Reference hot water temperature
52.3 °C
Mixed water at 40°C
258 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
89 %
COP
2.09
Heating up time
02:21 h:min
Standby power input
63.0 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
256 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.86 kW
4.60 kW
El input
1.47 kW
1.79 kW
COP
4.68
2.56
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
166 %
Prated
12.10 kW
10.00 kW
SCOP
5.78
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.20 kW
10.02 kW
COP Tj = +2°C
2.73
2.18
Pdh Tj = +7°C
7.77 kW
6.46 kW
COP Tj = +7°C
4.99
3.73
Pdh Tj = 12°C
3.46 kW
6.17 kW
COP Tj = 12°C
7.51
5.41
Pdh Tj = Tbiv
12.20 kW
10.02 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.20 kW
10.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
2.18
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2796 kWh
3154 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
121 %
Prated
9.80 kW
10.60 kW
SCOP
4.19
3.11
Tbiv
-17 °C
-15 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
6.24 kW
6.49 kW
COP Tj = -7°C
3.56
2.65
Pdh Tj = +2°C
3.66 kW
4.49 kW
COP Tj = +2°C
5.14
3.88
Pdh Tj = +7°C
2.82 kW
5.35 kW
COP Tj = +7°C
6.30
4.87
Pdh Tj = 12°C
3.06 kW
6.32 kW
COP Tj = 12°C
6.86
6.09
Pdh Tj = Tbiv
8.60 kW
8.70 kW
COP Tj = Tbiv
2.24
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.80 kW
8.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.69
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.80 kW
10.60 kW
Annual energy consumption Qhe
5762 kWh
8402 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.38
1.83
COP Tj = -15°C (if TOL<-20°C)
2.44
1.83
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
139 %
Prated
10.40 kW
8.60 kW
SCOP
4.73
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.07 kW
7.72 kW
COP Tj = -7°C
2.88
2.28
Pdh Tj = +2°C
5.93 kW
4.45 kW
COP Tj = +2°C
4.65
3.53
Pdh Tj = +7°C
3.75 kW
5.21 kW
COP Tj = +7°C
6.29
4.41
Pdh Tj = 12°C
3.11 kW
6.23 kW
COP Tj = 12°C
7.25
5.75
Pdh Tj = Tbiv
10.45 kW
8.59 kW
COP Tj = Tbiv
2.51
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.45 kW
8.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.89
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4540 kWh
5008 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.86 kW
4.60 kW
El input
1.47 kW
1.79 kW
COP
4.68
2.56
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
166 %
Prated
12.10 kW
10.00 kW
SCOP
5.78
4.24
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.20 kW
10.02 kW
COP Tj = +2°C
2.73
2.18
Pdh Tj = +7°C
7.77 kW
6.46 kW
COP Tj = +7°C
4.99
3.73
Pdh Tj = 12°C
3.46 kW
6.17 kW
COP Tj = 12°C
7.51
5.41
Pdh Tj = Tbiv
12.20 kW
10.02 kW
COP Tj = Tbiv
2.73
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.20 kW
10.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
2.18
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2796 kWh
3154 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
121 %
Prated
9.80 kW
10.60 kW
SCOP
4.19
3.11
Tbiv
-17 °C
-15 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
6.24 kW
6.49 kW
COP Tj = -7°C
3.56
2.65
Cdh Tj = -7 °C
Pdh Tj = +2°C
3.66 kW
4.49 kW
COP Tj = +2°C
5.14
3.88
Cdh Tj = +2 °C
Pdh Tj = +7°C
2.82 kW
5.35 kW
COP Tj = +7°C
6.30
4.87
Cdh Tj = +7 °C
Pdh Tj = 12°C
3.06 kW
6.32 kW
COP Tj = 12°C
6.86
6.09
Cdh Tj = +12 °C
Pdh Tj = Tbiv
8.60 kW
8.70 kW
COP Tj = Tbiv
2.24
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.80 kW
8.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
9.80 kW
10.60 kW
Annual energy consumption Qhe
5762 kWh
8402 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.38
1.83
COP Tj = -15°C (if TOL<-20°C)
2.44
1.83
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
139 %
Prated
10.40 kW
8.60 kW
SCOP
4.73
3.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.07 kW
7.72 kW
COP Tj = -7°C
2.88
2.28
Pdh Tj = +2°C
5.93 kW
4.45 kW
COP Tj = +2°C
4.65
3.53
Pdh Tj = +7°C
3.75 kW
5.21 kW
COP Tj = +7°C
6.29
4.41
Pdh Tj = 12°C
3.11 kW
6.23 kW
COP Tj = 12°C
7.25
5.75
Pdh Tj = Tbiv
10.45 kW
8.59 kW
COP Tj = Tbiv
2.51
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.45 kW
8.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.89
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4540 kWh
5008 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.19 kW
4.62 kW
El input
1.09 kW
1.65 kW
COP
4.76
2.80
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
233 %
161 %
Prated
11.80 kW
11.43 kW
SCOP
5.90
4.10
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.80 kW
11.43 kW
COP Tj = +2°C
2.98
2.14
Pdh Tj = +7°C
7.62 kW
7.90 kW
COP Tj = +7°C
5.11
3.54
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
7.61
5.38
Pdh Tj = Tbiv
11.80 kW
11.43 kW
COP Tj = Tbiv
2.98
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.80 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.98
2.14
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2673 kWh
3720 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
145 %
112 %
Prated
9.49 kW
8.88 kW
SCOP
3.71
2.87
Tbiv
-17 °C
-17 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.49
2.65
Pdh Tj = +2°C
7.25 kW
6.86 kW
COP Tj = +2°C
3.95
3.16
Pdh Tj = +7°C
5.48 kW
5.19 kW
COP Tj = +7°C
6.00
4.71
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.04
5.92
Pdh Tj = Tbiv
8.25 kW
7.71 kW
COP Tj = Tbiv
2.30
1.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.48 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.11
1.67
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.49 kW
8.88 kW
Annual energy consumption Qhe
6307 kWh
7636 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.80
7.29
COP Tj = -15°C (if TOL<-20°C)
2.54
1.90
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
137 %
Prated
9.97 kW
9.26 kW
SCOP
4.31
3.49
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.53 kW
8.41 kW
COP Tj = -7°C
2.89
2.18
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
3.88
3.50
Pdh Tj = +7°C
3.68 kW
5.12 kW
COP Tj = +7°C
6.30
4.42
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.35
5.51
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.54
1.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.82
WTOL
60 °C
60 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4776 kWh
5484 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.67 kW
4.39 kW
El input
0.98 kW
1.66 kW
COP
4.77
2.64
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
233 %
158 %
Prated
10.87 kW
11.43 kW
SCOP
5.89
4.02
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.87 kW
11.43 kW
COP Tj = +2°C
2.98
2.14
Pdh Tj = +7°C
7.30 kW
7.90 kW
COP Tj = +7°C
5.10
3.38
Pdh Tj = 12°C
3.13 kW
6.01 kW
COP Tj = 12°C
7.61
5.38
Pdh Tj = Tbiv
10.87 kW
11.43 kW
COP Tj = Tbiv
2.98
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.87 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.98
2.14
WTOL
60 °C
60 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
12 W
12 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2466 kWh
3799 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
143 %
111 %
Prated
9.05 kW
9.15 kW
SCOP
3.64
2.84
Tbiv
-17 °C
-16 °C
TOL
-18 °C
-17 °C
Pdh Tj = -7°C
5.98 kW
5.62 kW
COP Tj = -7°C
3.49
2.66
Pdh Tj = +2°C
5.40 kW
6.86 kW
COP Tj = +2°C
3.97
3.17
Pdh Tj = +7°C
2.77 kW
5.19 kW
COP Tj = +7°C
5.95
4.72
Pdh Tj = 12°C
3.07 kW
6.14 kW
COP Tj = 12°C
7.04
5.70
Pdh Tj = Tbiv
7.39 kW
7.71 kW
COP Tj = Tbiv
2.07
1.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.18 kW
6.32 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.12
1.67
WTOL
60 °C
60 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
12 W
12 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
9.05 kW
9.15 kW
Annual energy consumption Qhe
6132 kWh
7938 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.80
7.29
COP Tj = -15°C (if TOL<-20°C)
2.54
1.90
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
136 %
Prated
9.97 kW
9.33 kW
SCOP
4.32
3.48
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.14 kW
8.41 kW
COP Tj = -7°C
2.88
2.18
Pdh Tj = +2°C
5.48 kW
4.74 kW
COP Tj = +2°C
3.89
3.50
Pdh Tj = +7°C
3.54 kW
5.12 kW
COP Tj = +7°C
6.30
4.41
Pdh Tj = 12°C
3.11 kW
6.10 kW
COP Tj = 12°C
7.35
5.47
Pdh Tj = Tbiv
9.97 kW
9.33 kW
COP Tj = Tbiv
2.54
1.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.97 kW
9.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.82
WTOL
60 °C
60 °C
Poff
23 W
23 W
PTO
23 W
23 W
PSB
23 W
23 W
PCK
12 W
12 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4766 kWh
5534 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.18 kW
7.41 kW
El input
1.06 kW
2.61 kW
COP
4.89
2.84
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
24 dB(A)
24 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
237 %
161 %
Prated
11.80 kW
11.40 kW
SCOP
6.00
4.11
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.80 kW
11.43 kW
COP Tj = +2°C
2.97
2.08
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
7.71 kW
7.96 kW
COP Tj = +7°C
5.04
3.53
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
3.21 kW
5.96 kW
COP Tj = 12°C
8.31
5.57
Cdh Tj = +12 °C
1.000
0.970
Pdh Tj = Tbiv
11.80 kW
11.43 kW
COP Tj = Tbiv
2.97
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.80 kW
11.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.97
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
27 W
27 W
PSB
26 W
26 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2628 kWh
3705 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
24 dB(A)
24 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
168 %
119 %
Prated
9.50 kW
8.90 kW
SCOP
4.16
3.05
Tbiv
-17 °C
-12 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
5.79 kW
5.78 kW
COP Tj = -7°C
3.72
2.68
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.50 kW
3.83 kW
COP Tj = +2°C
4.89
3.28
Cdh Tj = +2 °C
1.000
0.980
Pdh Tj = +7°C
2.77 kW
5.23 kW
COP Tj = +7°C
7.49
4.71
Cdh Tj = +7 °C
0.930
0.980
Pdh Tj = 12°C
3.20 kW
6.11 kW
COP Tj = 12°C
8.18
6.04
Cdh Tj = +12 °C
0.930
0.970
Pdh Tj = Tbiv
8.55 kW
6.42 kW
COP Tj = Tbiv
2.25
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.86 kW
5.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
27 W
27 W
PSB
26 W
26 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Gas
Gas
Supplementary Heater: PSUP
9.50 kW
8.90 kW
Annual energy consumption Qhe
5487 kWh
7194 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.31
COP Tj = -15°C (if TOL<-20°C)
2.46
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
24 dB(A)
24 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
194 %
136 %
Prated
10.00 kW
9.30 kW
SCOP
4.92
3.47
Tbiv
-10 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.31 kW
8.39 kW
COP Tj = -7°C
3.00
2.15
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
5.17 kW
4.65 kW
COP Tj = +2°C
4.88
3.48
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
3.70 kW
5.06 kW
COP Tj = +7°C
6.56
4.46
Cdh Tj = +7 °C
1.000
0.980
Pdh Tj = 12°C
3.22 kW
6.05 kW
COP Tj = 12°C
8.28
5.81
Cdh Tj = +12 °C
0.930
0.970
Pdh Tj = Tbiv
10.23 kW
8.39 kW
COP Tj = Tbiv
2.60
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.23 kW
6.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
27 W
27 W
PSB
26 W
26 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
Gas
Supplementary Heater: PSUP
0.00 kW
2.97 kW
Annual energy consumption Qhe
4198 kWh
5535 kWh