Certificate holders

Subtype

Bosch Compress 7000iAW 13 OR and IR, Compress 6000 AW-13/s, Bosch CS7001iAW 13

Certificate Holder
Bosch Thermotechnik GmbH
Junkersstraße 20 - 24
73249 Wernau
Germany
Registration number
011-1W0125
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Bosch Compress 7000iAW 13 OR and IR, Compress 6000 AW-13/s, Bosch CS7001iAW 13
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

3,300 kg

Certification Date
18.07.2017
Testing basis
HP KEYMARK certification scheme rules rev. 11
Generate PDF Export model CSV
  • Number of models 31

Models

Bosch CS7000iAW 13 IRMS-T
Configure model
Model name
Bosch CS7000iAW 13 IRMS-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.67 kW

4.39 kW

El input

0.93 kW

1.62 kW

COP

5.00

2.71

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

163 %

Prated

10.87 kW

11.43 kW

SCOP

6.29

4.15

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.87 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.30 kW

7.90 kW

COP Tj = +7°C

5.37

3.45

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

10.87 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.87 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2308 kWh

3681 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

113 %

Prated

9.05 kW

9.15 kW

SCOP

3.78

2.90

Tbiv

-17 °C

-16 °C

TOL

-18 °C

-17 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Pdh Tj = +2°C

5.40 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Pdh Tj = +7°C

2.77 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

5.90

Pdh Tj = Tbiv

7.39 kW

7.71 kW

COP Tj = Tbiv

2.11

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.18 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.05 kW

9.15 kW

Annual energy consumption Qhe

5895 kWh

7769 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.80

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.14 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.54 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4558 kWh

5389 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

102 %

COP

2.35

Heating up time

01:51 h:min

Standby power input

69.0 W

Reference hot water temperature

51.3 °C

Mixed water at 40°C

252 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

75 %

COP

1.73

Heating up time

02:37 h:min

Standby power input

94.0 W

Reference hot water temperature

51.3 °C

Mixed water at 40°C

257 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.11

Heating up time

02:15 h:min

Standby power input

71.0 W

Reference hot water temperature

52.2 °C

Mixed water at 40°C

255 l

Bosch CS7000iAW 13 IRM-T
Configure model
Model name
Bosch CS7000iAW 13 IRM-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.67 kW

4.39 kW

El input

0.93 kW

1.62 kW

COP

5.00

2.71

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

163 %

Prated

10.87 kW

11.43 kW

SCOP

6.29

4.15

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.87 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.30 kW

7.90 kW

COP Tj = +7°C

5.37

3.45

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

10.87 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.87 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2308 kWh

3681 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

113 %

Prated

9.05 kW

9.15 kW

SCOP

3.78

2.90

Tbiv

-17 °C

-16 °C

TOL

-18 °C

-17 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Pdh Tj = +2°C

5.40 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Pdh Tj = +7°C

2.77 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

5.90

Pdh Tj = Tbiv

7.39 kW

7.71 kW

COP Tj = Tbiv

2.11

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.18 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.05 kW

9.15 kW

Annual energy consumption Qhe

5895 kWh

7769 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.80

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.14 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.54 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4558 kWh

5389 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

111 %

COP

2.55

Heating up time

01:49 h:min

Standby power input

66.0 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

266 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

76 %

COP

1.77

Heating up time

02:34 h:min

Standby power input

83.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

269 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

92 %

COP

2.15

Heating up time

02:12 h:min

Standby power input

68.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

265 l

Bosch CS7000iAW 13 IRB-T
Configure model
Model name
Bosch CS7000iAW 13 IRB-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.67 kW

4.39 kW

El input

0.93 kW

1.62 kW

COP

5.00

2.71

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

163 %

Prated

10.87 kW

11.43 kW

SCOP

6.29

4.15

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.87 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.30 kW

7.90 kW

COP Tj = +7°C

5.37

3.45

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

10.87 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.87 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2308 kWh

3681 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

113 %

Prated

9.05 kW

9.15 kW

SCOP

3.78

2.90

Tbiv

-17 °C

-16 °C

TOL

-18 °C

-17 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

5.40 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

2.77 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

5.90

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

7.39 kW

7.71 kW

COP Tj = Tbiv

2.11

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.18 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

9.05 kW

9.15 kW

Annual energy consumption Qhe

5895 kWh

7769 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.80

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.14 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.54 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4558 kWh

5389 kWh

Bosch CS7000iAW 13 IRE-T
Configure model
Model name
Bosch CS7000iAW 13 IRE-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.67 kW

4.39 kW

El input

0.93 kW

1.62 kW

COP

5.00

2.71

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

163 %

Prated

10.87 kW

11.43 kW

SCOP

6.29

4.15

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.87 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.30 kW

7.90 kW

COP Tj = +7°C

5.37

3.45

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

10.87 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.87 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2308 kWh

3681 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

113 %

Prated

9.05 kW

9.15 kW

SCOP

3.78

2.90

Tbiv

-17 °C

-16 °C

TOL

-18 °C

-17 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Pdh Tj = +2°C

5.40 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Pdh Tj = +7°C

2.77 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

5.90

Pdh Tj = Tbiv

7.39 kW

7.71 kW

COP Tj = Tbiv

2.11

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.18 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.05 kW

9.15 kW

Annual energy consumption Qhe

5895 kWh

7769 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.80

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.14 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.54 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4558 kWh

5389 kWh

Bosch CS7000iAW 13 ORMS-T
Configure model
Model name
Bosch CS7000iAW 13 ORMS-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.19 kW

4.62 kW

El input

1.04 kW

1.62 kW

COP

4.98

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

167 %

Prated

11.80 kW

11.43 kW

SCOP

6.30

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.80 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.62 kW

7.90 kW

COP Tj = +7°C

5.37

3.61

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

11.80 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2504 kWh

3603 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

114 %

Prated

9.49 kW

8.87 kW

SCOP

3.87

2.93

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Pdh Tj = +2°C

7.25 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Pdh Tj = +7°C

5.48 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

6.14

Pdh Tj = Tbiv

8.25 kW

7.71 kW

COP Tj = Tbiv

2.36

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.48 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.49 kW

8.87 kW

Annual energy consumption Qhe

6039 kWh

7456 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.25

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.53 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.68 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4562 kWh

5389 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

102 %

COP

2.35

Heating up time

01:51 h:min

Standby power input

69.0 W

Reference hot water temperature

51.3 °C

Mixed water at 40°C

252 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

75 %

COP

1.73

Heating up time

02:37 h:min

Standby power input

94.0 W

Reference hot water temperature

51.3 °C

Mixed water at 40°C

257 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.11

Heating up time

02:15 h:min

Standby power input

71.0 W

Reference hot water temperature

52.2 °C

Mixed water at 40°C

255 l

Bosch CS7000iAW 13 ORM-T
Configure model
Model name
Bosch CS7000iAW 13 ORM-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.19 kW

4.62 kW

El input

1.04 kW

1.62 kW

COP

4.98

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

167 %

Prated

11.80 kW

11.43 kW

SCOP

6.30

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.80 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.62 kW

7.90 kW

COP Tj = +7°C

5.37

3.61

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

11.80 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2504 kWh

3603 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

114 %

Prated

9.49 kW

8.87 kW

SCOP

3.87

2.93

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Pdh Tj = +2°C

7.25 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Pdh Tj = +7°C

5.48 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

6.14

Pdh Tj = Tbiv

8.25 kW

7.71 kW

COP Tj = Tbiv

2.36

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.48 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.49 kW

8.87 kW

Annual energy consumption Qhe

6039 kWh

7456 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.25

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.53 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.68 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4562 kWh

5389 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

111 %

COP

2.55

Heating up time

01:48 h:min

Standby power input

66.0 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

266 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

76 %

COP

1.77

Heating up time

02:34 h:min

Standby power input

83.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

269 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

92 %

COP

2.15

Heating up time

02:12 h:min

Standby power input

68.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

265 l

Bosch CS7000iAW 13 ORB-T
Configure model
Model name
Bosch CS7000iAW 13 ORB-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.19 kW

4.62 kW

El input

1.04 kW

1.62 kW

COP

4.98

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

167 %

Prated

11.80 kW

11.43 kW

SCOP

6.30

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.80 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.62 kW

7.90 kW

COP Tj = +7°C

5.37

3.61

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

11.80 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2504 kWh

3603 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

114 %

Prated

9.49 kW

8.87 kW

SCOP

3.87

2.93

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

7.25 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

5.48 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

6.14

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

8.25 kW

7.71 kW

COP Tj = Tbiv

2.36

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.48 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

9.49 kW

8.87 kW

Annual energy consumption Qhe

6039 kWh

7456 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.25

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.53 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.68 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4562 kWh

5389 kWh

Bosch CS7000iAW 13 ORE-T
Configure model
Model name
Bosch CS7000iAW 13 ORE-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.19 kW

4.62 kW

El input

1.04 kW

1.62 kW

COP

4.98

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

167 %

Prated

11.80 kW

11.43 kW

SCOP

6.30

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.80 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.62 kW

7.90 kW

COP Tj = +7°C

5.37

3.61

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

11.80 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2504 kWh

3603 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

114 %

Prated

9.49 kW

8.87 kW

SCOP

3.87

2.93

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Pdh Tj = +2°C

7.25 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Pdh Tj = +7°C

5.48 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

6.14

Pdh Tj = Tbiv

8.25 kW

7.71 kW

COP Tj = Tbiv

2.36

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.48 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.49 kW

8.87 kW

Annual energy consumption Qhe

6039 kWh

7456 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.25

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.53 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.68 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4562 kWh

5389 kWh

Bosch CS7000iAW 13 ORMS-S
Configure model
Model name
Bosch CS7000iAW 13 ORMS-S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.86 kW

4.60 kW

El input

1.47 kW

1.79 kW

COP

4.68

2.56

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

166 %

Prated

12.10 kW

10.00 kW

SCOP

5.78

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.20 kW

10.02 kW

COP Tj = +2°C

2.73

2.18

Pdh Tj = +7°C

7.77 kW

6.46 kW

COP Tj = +7°C

4.99

3.73

Pdh Tj = 12°C

3.46 kW

6.17 kW

COP Tj = 12°C

7.51

5.41

Pdh Tj = Tbiv

12.20 kW

10.02 kW

COP Tj = Tbiv

2.73

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.20 kW

10.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.18

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2796 kWh

3154 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

121 %

Prated

9.80 kW

10.60 kW

SCOP

4.19

3.11

Tbiv

-17 °C

-15 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

6.24 kW

6.49 kW

COP Tj = -7°C

3.56

2.65

Pdh Tj = +2°C

3.66 kW

4.49 kW

COP Tj = +2°C

5.14

3.88

Pdh Tj = +7°C

2.82 kW

5.35 kW

COP Tj = +7°C

6.30

4.87

Pdh Tj = 12°C

3.06 kW

6.32 kW

COP Tj = 12°C

6.86

6.09

Pdh Tj = Tbiv

8.60 kW

8.70 kW

COP Tj = Tbiv

2.24

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

8.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.80 kW

10.60 kW

Annual energy consumption Qhe

5762 kWh

8402 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.38

1.83

COP Tj = -15°C (if TOL<-20°C)

2.44

1.83

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

139 %

Prated

10.40 kW

8.60 kW

SCOP

4.73

3.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.07 kW

7.72 kW

COP Tj = -7°C

2.88

2.28

Pdh Tj = +2°C

5.93 kW

4.45 kW

COP Tj = +2°C

4.65

3.53

Pdh Tj = +7°C

3.75 kW

5.21 kW

COP Tj = +7°C

6.29

4.41

Pdh Tj = 12°C

3.11 kW

6.23 kW

COP Tj = 12°C

7.25

5.75

Pdh Tj = Tbiv

10.45 kW

8.59 kW

COP Tj = Tbiv

2.51

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.45 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4540 kWh

5008 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

100 %

COP

2.32

Heating up time

01:48 h:min

Standby power input

57.0 W

Reference hot water temperature

51.6 °C

Mixed water at 40°C

253 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

80 %

COP

1.87

Heating up time

02:43 h:min

Standby power input

84.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

258 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

89 %

COP

2.09

Heating up time

02:21 h:min

Standby power input

63.0 W

Reference hot water temperature

51.9 °C

Mixed water at 40°C

256 l

Bosch CS7000iAW 13 ORM-S
Configure model
Model name
Bosch CS7000iAW 13 ORM-S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.86 kW

4.60 kW

El input

1.47 kW

1.79 kW

COP

4.68

2.56

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

166 %

Prated

12.10 kW

10.00 kW

SCOP

5.78

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.20 kW

10.02 kW

COP Tj = +2°C

2.73

2.18

Pdh Tj = +7°C

7.77 kW

6.46 kW

COP Tj = +7°C

4.99

3.73

Pdh Tj = 12°C

3.46 kW

6.17 kW

COP Tj = 12°C

7.51

5.41

Pdh Tj = Tbiv

12.20 kW

10.02 kW

COP Tj = Tbiv

2.73

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.20 kW

10.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.18

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2796 kWh

3154 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

121 %

Prated

9.80 kW

10.60 kW

SCOP

4.19

3.11

Tbiv

-17 °C

-15 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

6.24 kW

6.49 kW

COP Tj = -7°C

3.56

2.65

Pdh Tj = +2°C

3.66 kW

4.49 kW

COP Tj = +2°C

5.14

3.88

Pdh Tj = +7°C

2.82 kW

5.35 kW

COP Tj = +7°C

6.30

4.87

Pdh Tj = 12°C

3.06 kW

6.32 kW

COP Tj = 12°C

6.86

6.09

Pdh Tj = Tbiv

8.60 kW

8.70 kW

COP Tj = Tbiv

2.24

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

8.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.80 kW

10.60 kW

Annual energy consumption Qhe

5762 kWh

8402 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.38

1.83

COP Tj = -15°C (if TOL<-20°C)

2.44

1.83

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

139 %

Prated

10.40 kW

8.60 kW

SCOP

4.73

3.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.07 kW

7.72 kW

COP Tj = -7°C

2.88

2.28

Pdh Tj = +2°C

5.93 kW

4.45 kW

COP Tj = +2°C

4.65

3.53

Pdh Tj = +7°C

3.75 kW

5.21 kW

COP Tj = +7°C

6.29

4.41

Pdh Tj = 12°C

3.11 kW

6.23 kW

COP Tj = 12°C

7.25

5.75

Pdh Tj = Tbiv

10.45 kW

8.59 kW

COP Tj = Tbiv

2.51

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.45 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4540 kWh

5008 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.52

Heating up time

01:46 h:min

Standby power input

55.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

267 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

82 %

COP

1.91

Heating up time

02:41 h:min

Standby power input

74.0 W

Reference hot water temperature

53.5 °C

Mixed water at 40°C

270 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.13

Heating up time

02:18 h:min

Standby power input

60.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

266 l

Bosch CS7000iAW 13 ORB-S
Configure model
Model name
Bosch CS7000iAW 13 ORB-S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.86 kW

4.60 kW

El input

1.47 kW

1.79 kW

COP

4.68

2.56

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

166 %

Prated

12.10 kW

10.00 kW

SCOP

5.78

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.20 kW

10.02 kW

COP Tj = +2°C

2.73

2.18

Pdh Tj = +7°C

7.77 kW

6.46 kW

COP Tj = +7°C

4.99

3.73

Pdh Tj = 12°C

3.46 kW

6.17 kW

COP Tj = 12°C

7.51

5.41

Pdh Tj = Tbiv

12.20 kW

10.02 kW

COP Tj = Tbiv

2.73

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.20 kW

10.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.18

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2796 kWh

3154 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

121 %

Prated

9.80 kW

10.60 kW

SCOP

4.19

3.11

Tbiv

-17 °C

-15 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

6.24 kW

6.49 kW

COP Tj = -7°C

3.56

2.65

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

3.66 kW

4.49 kW

COP Tj = +2°C

5.14

3.88

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

2.82 kW

5.35 kW

COP Tj = +7°C

6.30

4.87

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

3.06 kW

6.32 kW

COP Tj = 12°C

6.86

6.09

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

8.60 kW

8.70 kW

COP Tj = Tbiv

2.24

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

8.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

9.80 kW

10.60 kW

Annual energy consumption Qhe

5762 kWh

8402 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.38

1.83

COP Tj = -15°C (if TOL<-20°C)

2.44

1.83

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

139 %

Prated

10.40 kW

8.60 kW

SCOP

4.73

3.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.07 kW

7.72 kW

COP Tj = -7°C

2.88

2.28

Pdh Tj = +2°C

5.93 kW

4.45 kW

COP Tj = +2°C

4.65

3.53

Pdh Tj = +7°C

3.75 kW

5.21 kW

COP Tj = +7°C

6.29

4.41

Pdh Tj = 12°C

3.11 kW

6.23 kW

COP Tj = 12°C

7.25

5.75

Pdh Tj = Tbiv

10.45 kW

8.59 kW

COP Tj = Tbiv

2.51

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.45 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4540 kWh

5008 kWh

Bosch CS7000iAW 13 ORE-S
Configure model
Model name
Bosch CS7000iAW 13 ORE-S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.86 kW

4.60 kW

El input

1.47 kW

1.79 kW

COP

4.68

2.56

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

166 %

Prated

12.10 kW

10.00 kW

SCOP

5.78

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.20 kW

10.02 kW

COP Tj = +2°C

2.73

2.18

Pdh Tj = +7°C

7.77 kW

6.46 kW

COP Tj = +7°C

4.99

3.73

Pdh Tj = 12°C

3.46 kW

6.17 kW

COP Tj = 12°C

7.51

5.41

Pdh Tj = Tbiv

12.20 kW

10.02 kW

COP Tj = Tbiv

2.73

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.20 kW

10.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.18

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2796 kWh

3154 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

121 %

Prated

9.80 kW

10.60 kW

SCOP

4.19

3.11

Tbiv

-17 °C

-15 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

6.24 kW

6.49 kW

COP Tj = -7°C

3.56

2.65

Pdh Tj = +2°C

3.66 kW

4.49 kW

COP Tj = +2°C

5.14

3.88

Pdh Tj = +7°C

2.82 kW

5.35 kW

COP Tj = +7°C

6.30

4.87

Pdh Tj = 12°C

3.06 kW

6.32 kW

COP Tj = 12°C

6.86

6.09

Pdh Tj = Tbiv

8.60 kW

8.70 kW

COP Tj = Tbiv

2.24

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

8.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.80 kW

10.60 kW

Annual energy consumption Qhe

5762 kWh

8402 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.38

1.83

COP Tj = -15°C (if TOL<-20°C)

2.44

1.83

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

139 %

Prated

10.40 kW

8.60 kW

SCOP

4.73

3.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.07 kW

7.72 kW

COP Tj = -7°C

2.88

2.28

Pdh Tj = +2°C

5.93 kW

4.45 kW

COP Tj = +2°C

4.65

3.53

Pdh Tj = +7°C

3.75 kW

5.21 kW

COP Tj = +7°C

6.29

4.41

Pdh Tj = 12°C

3.11 kW

6.23 kW

COP Tj = 12°C

7.25

5.75

Pdh Tj = Tbiv

10.45 kW

8.59 kW

COP Tj = Tbiv

2.51

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.45 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4540 kWh

5008 kWh

Bosch Compress 6000 AW-13 AWB
Configure model
Model name
Bosch Compress 6000 AW-13 AWB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.19 kW

4.62 kW

El input

1.04 kW

1.62 kW

COP

4.98

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

167 %

Prated

11.80 kW

11.43 kW

SCOP

6.30

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.80 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.62 kW

7.90 kW

COP Tj = +7°C

5.37

3.61

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

11.80 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2504 kWh

3603 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

114 %

Prated

9.49 kW

8.87 kW

SCOP

3.87

2.93

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

7.25 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

5.48 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

6.14

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

8.25 kW

7.71 kW

COP Tj = Tbiv

2.36

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.48 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

9.49 kW

8.87 kW

Annual energy consumption Qhe

6039 kWh

7456 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.25

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.53 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.68 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4562 kWh

5389 kWh

Bosch Compress 6000 AW-13 AWM
Configure model
Model name
Bosch Compress 6000 AW-13 AWM
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.19 kW

4.62 kW

El input

1.04 kW

1.62 kW

COP

4.98

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

167 %

Prated

11.80 kW

11.43 kW

SCOP

6.30

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.80 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.62 kW

7.90 kW

COP Tj = +7°C

5.37

3.61

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

11.80 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2504 kWh

3603 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

114 %

Prated

9.49 kW

8.87 kW

SCOP

3.87

2.93

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Pdh Tj = +2°C

7.25 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Pdh Tj = +7°C

5.48 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

6.14

Pdh Tj = Tbiv

8.25 kW

7.71 kW

COP Tj = Tbiv

2.36

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.48 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.49 kW

8.87 kW

Annual energy consumption Qhe

6039 kWh

7456 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.25

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.53 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.68 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4562 kWh

5389 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

111 %

COP

2.55

Heating up time

01:48 h:min

Standby power input

66.0 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

266 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

76 %

COP

1.77

Heating up time

02:34 h:min

Standby power input

83.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

269 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

92 %

COP

2.15

Heating up time

02:12 h:min

Standby power input

68.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

265 l

Bosch Compress 6000 AW-13 AWE
Configure model
Model name
Bosch Compress 6000 AW-13 AWE
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.19 kW

4.62 kW

El input

1.04 kW

1.62 kW

COP

4.98

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

167 %

Prated

11.80 kW

11.43 kW

SCOP

6.30

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.80 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.62 kW

7.90 kW

COP Tj = +7°C

5.37

3.61

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

11.80 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2504 kWh

3603 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

114 %

Prated

9.49 kW

8.87 kW

SCOP

3.87

2.93

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Pdh Tj = +2°C

7.25 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Pdh Tj = +7°C

5.48 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

6.14

Pdh Tj = Tbiv

8.25 kW

7.71 kW

COP Tj = Tbiv

2.36

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.48 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.49 kW

8.87 kW

Annual energy consumption Qhe

6039 kWh

7456 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.25

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.53 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.68 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4562 kWh

5389 kWh

Bosch Compress 6000 AW-13 AWMS
Configure model
Model name
Bosch Compress 6000 AW-13 AWMS
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.19 kW

4.62 kW

El input

1.04 kW

1.62 kW

COP

4.98

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

167 %

Prated

11.80 kW

11.43 kW

SCOP

6.30

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.80 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.62 kW

7.90 kW

COP Tj = +7°C

5.37

3.61

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

11.80 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2504 kWh

3603 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

114 %

Prated

9.49 kW

8.87 kW

SCOP

3.87

2.93

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Pdh Tj = +2°C

7.25 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Pdh Tj = +7°C

5.48 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

6.14

Pdh Tj = Tbiv

8.25 kW

7.71 kW

COP Tj = Tbiv

2.36

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.48 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.49 kW

8.87 kW

Annual energy consumption Qhe

6039 kWh

7456 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.25

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.53 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.68 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4562 kWh

5389 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

102 %

COP

2.35

Heating up time

01:51 h:min

Standby power input

69.0 W

Reference hot water temperature

51.3 °C

Mixed water at 40°C

252 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

75 %

COP

1.73

Heating up time

02:37 h:min

Standby power input

94.0 W

Reference hot water temperature

51.3 °C

Mixed water at 40°C

257 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.11

Heating up time

02:15 h:min

Standby power input

71.0 W

Reference hot water temperature

52.2 °C

Mixed water at 40°C

255 l

Bosch Compress 6000 AW-13s AWB
Configure model
Model name
Bosch Compress 6000 AW-13s AWB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.86 kW

4.60 kW

El input

1.47 kW

1.79 kW

COP

4.68

2.56

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

166 %

Prated

12.10 kW

10.00 kW

SCOP

5.78

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.20 kW

10.02 kW

COP Tj = +2°C

2.73

2.18

Pdh Tj = +7°C

7.77 kW

6.46 kW

COP Tj = +7°C

4.99

3.73

Pdh Tj = 12°C

3.46 kW

6.17 kW

COP Tj = 12°C

7.51

5.41

Pdh Tj = Tbiv

12.20 kW

10.02 kW

COP Tj = Tbiv

2.73

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.20 kW

10.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.18

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2796 kWh

3154 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

121 %

Prated

9.80 kW

10.60 kW

SCOP

4.19

3.11

Tbiv

-17 °C

-15 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

6.24 kW

6.49 kW

COP Tj = -7°C

3.56

2.65

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

3.66 kW

4.49 kW

COP Tj = +2°C

5.14

3.88

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

2.82 kW

5.35 kW

COP Tj = +7°C

6.30

4.87

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

3.06 kW

6.32 kW

COP Tj = 12°C

6.86

6.09

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

8.60 kW

8.70 kW

COP Tj = Tbiv

2.24

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

8.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

9.80 kW

10.60 kW

Annual energy consumption Qhe

5762 kWh

8402 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.38

1.83

COP Tj = -15°C (if TOL<-20°C)

2.44

1.83

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

139 %

Prated

10.40 kW

8.60 kW

SCOP

4.73

3.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.07 kW

7.72 kW

COP Tj = -7°C

2.88

2.28

Pdh Tj = +2°C

5.93 kW

4.45 kW

COP Tj = +2°C

4.65

3.53

Pdh Tj = +7°C

3.75 kW

5.21 kW

COP Tj = +7°C

6.29

4.41

Pdh Tj = 12°C

3.11 kW

6.23 kW

COP Tj = 12°C

7.25

5.75

Pdh Tj = Tbiv

10.45 kW

8.59 kW

COP Tj = Tbiv

2.51

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.45 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4540 kWh

5008 kWh

Bosch Compress 6000 AW-13s AWM
Configure model
Model name
Bosch Compress 6000 AW-13s AWM
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.86 kW

4.60 kW

El input

1.47 kW

1.79 kW

COP

4.68

2.56

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

166 %

Prated

12.10 kW

10.00 kW

SCOP

5.78

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.20 kW

10.02 kW

COP Tj = +2°C

2.73

2.18

Pdh Tj = +7°C

7.77 kW

6.46 kW

COP Tj = +7°C

4.99

3.73

Pdh Tj = 12°C

3.46 kW

6.17 kW

COP Tj = 12°C

7.51

5.41

Pdh Tj = Tbiv

12.20 kW

10.02 kW

COP Tj = Tbiv

2.73

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.20 kW

10.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.18

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2796 kWh

3154 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

121 %

Prated

9.80 kW

10.60 kW

SCOP

4.19

3.11

Tbiv

-17 °C

-15 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

6.24 kW

6.49 kW

COP Tj = -7°C

3.56

2.65

Pdh Tj = +2°C

3.66 kW

4.49 kW

COP Tj = +2°C

5.14

3.88

Pdh Tj = +7°C

2.82 kW

5.35 kW

COP Tj = +7°C

6.30

4.87

Pdh Tj = 12°C

3.06 kW

6.32 kW

COP Tj = 12°C

6.86

6.09

Pdh Tj = Tbiv

8.60 kW

8.70 kW

COP Tj = Tbiv

2.24

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

8.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.80 kW

10.60 kW

Annual energy consumption Qhe

5762 kWh

8402 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.38

1.83

COP Tj = -15°C (if TOL<-20°C)

2.44

1.83

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

139 %

Prated

10.40 kW

8.60 kW

SCOP

4.73

3.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.07 kW

7.72 kW

COP Tj = -7°C

2.88

2.28

Pdh Tj = +2°C

5.93 kW

4.45 kW

COP Tj = +2°C

4.65

3.53

Pdh Tj = +7°C

3.75 kW

5.21 kW

COP Tj = +7°C

6.29

4.41

Pdh Tj = 12°C

3.11 kW

6.23 kW

COP Tj = 12°C

7.25

5.75

Pdh Tj = Tbiv

10.45 kW

8.59 kW

COP Tj = Tbiv

2.51

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.45 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4540 kWh

5008 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.52

Heating up time

01:46 h:min

Standby power input

55.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

267 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

82 %

COP

1.91

Heating up time

02:41 h:min

Standby power input

74.0 W

Reference hot water temperature

53.5 °C

Mixed water at 40°C

270 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.13

Heating up time

02:18 h:min

Standby power input

60.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

266 l

Bosch Compress 6000 AW-13s AWMS
Configure model
Model name
Bosch Compress 6000 AW-13s AWMS
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.86 kW

4.60 kW

El input

1.47 kW

1.79 kW

COP

4.68

2.56

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

166 %

Prated

12.10 kW

10.00 kW

SCOP

5.78

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.20 kW

10.02 kW

COP Tj = +2°C

2.73

2.18

Pdh Tj = +7°C

7.77 kW

6.46 kW

COP Tj = +7°C

4.99

3.73

Pdh Tj = 12°C

3.46 kW

6.17 kW

COP Tj = 12°C

7.51

5.41

Pdh Tj = Tbiv

12.20 kW

10.02 kW

COP Tj = Tbiv

2.73

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.20 kW

10.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.18

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2796 kWh

3154 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

121 %

Prated

9.80 kW

10.60 kW

SCOP

4.19

3.11

Tbiv

-17 °C

-15 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

6.24 kW

6.49 kW

COP Tj = -7°C

3.56

2.65

Pdh Tj = +2°C

3.66 kW

4.49 kW

COP Tj = +2°C

5.14

3.88

Pdh Tj = +7°C

2.82 kW

5.35 kW

COP Tj = +7°C

6.30

4.87

Pdh Tj = 12°C

3.06 kW

6.32 kW

COP Tj = 12°C

6.86

6.09

Pdh Tj = Tbiv

8.60 kW

8.70 kW

COP Tj = Tbiv

2.24

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

8.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.80 kW

10.60 kW

Annual energy consumption Qhe

5762 kWh

8402 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.38

1.83

COP Tj = -15°C (if TOL<-20°C)

2.44

1.83

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

139 %

Prated

10.40 kW

8.60 kW

SCOP

4.73

3.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.07 kW

7.72 kW

COP Tj = -7°C

2.88

2.28

Pdh Tj = +2°C

5.93 kW

4.45 kW

COP Tj = +2°C

4.65

3.53

Pdh Tj = +7°C

3.75 kW

5.21 kW

COP Tj = +7°C

6.29

4.41

Pdh Tj = 12°C

3.11 kW

6.23 kW

COP Tj = 12°C

7.25

5.75

Pdh Tj = Tbiv

10.45 kW

8.59 kW

COP Tj = Tbiv

2.51

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.45 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4540 kWh

5008 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

100 %

COP

2.32

Heating up time

01:48 h:min

Standby power input

57.0 W

Reference hot water temperature

51.6 °C

Mixed water at 40°C

253 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

80 %

COP

1.87

Heating up time

02:43 h:min

Standby power input

84.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

258 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

89 %

COP

2.09

Heating up time

02:21 h:min

Standby power input

63.0 W

Reference hot water temperature

51.9 °C

Mixed water at 40°C

256 l

Bosch Compress 6000 AW-13s AWE
Configure model
Model name
Bosch Compress 6000 AW-13s AWE
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.86 kW

4.60 kW

El input

1.47 kW

1.79 kW

COP

4.68

2.56

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

166 %

Prated

12.10 kW

10.00 kW

SCOP

5.78

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.20 kW

10.02 kW

COP Tj = +2°C

2.73

2.18

Pdh Tj = +7°C

7.77 kW

6.46 kW

COP Tj = +7°C

4.99

3.73

Pdh Tj = 12°C

3.46 kW

6.17 kW

COP Tj = 12°C

7.51

5.41

Pdh Tj = Tbiv

12.20 kW

10.02 kW

COP Tj = Tbiv

2.73

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.20 kW

10.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.18

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2796 kWh

3154 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

121 %

Prated

9.80 kW

10.60 kW

SCOP

4.19

3.11

Tbiv

-17 °C

-15 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

6.24 kW

6.49 kW

COP Tj = -7°C

3.56

2.65

Pdh Tj = +2°C

3.66 kW

4.49 kW

COP Tj = +2°C

5.14

3.88

Pdh Tj = +7°C

2.82 kW

5.35 kW

COP Tj = +7°C

6.30

4.87

Pdh Tj = 12°C

3.06 kW

6.32 kW

COP Tj = 12°C

6.86

6.09

Pdh Tj = Tbiv

8.60 kW

8.70 kW

COP Tj = Tbiv

2.24

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

8.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.80 kW

10.60 kW

Annual energy consumption Qhe

5762 kWh

8402 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.38

1.83

COP Tj = -15°C (if TOL<-20°C)

2.44

1.83

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

139 %

Prated

10.40 kW

8.60 kW

SCOP

4.73

3.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.07 kW

7.72 kW

COP Tj = -7°C

2.88

2.28

Pdh Tj = +2°C

5.93 kW

4.45 kW

COP Tj = +2°C

4.65

3.53

Pdh Tj = +7°C

3.75 kW

5.21 kW

COP Tj = +7°C

6.29

4.41

Pdh Tj = 12°C

3.11 kW

6.23 kW

COP Tj = 12°C

7.25

5.75

Pdh Tj = Tbiv

10.45 kW

8.59 kW

COP Tj = Tbiv

2.51

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.45 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4540 kWh

5008 kWh

Bosch CS7001iAW 13 ORMS-T
Configure model
Model name
Bosch CS7001iAW 13 ORMS-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.19 kW

4.62 kW

El input

1.04 kW

1.62 kW

COP

4.98

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

167 %

Prated

11.80 kW

11.43 kW

SCOP

6.30

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.80 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.62 kW

7.90 kW

COP Tj = +7°C

5.37

3.61

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

11.80 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2504 kWh

3603 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

114 %

Prated

9.49 kW

8.87 kW

SCOP

3.87

2.93

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Pdh Tj = +2°C

7.25 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Pdh Tj = +7°C

5.48 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

6.14

Pdh Tj = Tbiv

8.25 kW

7.71 kW

COP Tj = Tbiv

2.36

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.48 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.49 kW

8.87 kW

Annual energy consumption Qhe

6039 kWh

7456 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.25

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.53 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.68 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4562 kWh

5389 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

102 %

COP

2.35

Heating up time

01:51 h:min

Standby power input

69.0 W

Reference hot water temperature

51.3 °C

Mixed water at 40°C

252 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

75 %

COP

1.73

Heating up time

02:37 h:min

Standby power input

94.0 W

Reference hot water temperature

51.3 °C

Mixed water at 40°C

257 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.11

Heating up time

02:15 h:min

Standby power input

71.0 W

Reference hot water temperature

52.2 °C

Mixed water at 40°C

255 l

Bosch CS7001iAW 13 ORM-T
Configure model
Model name
Bosch CS7001iAW 13 ORM-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.19 kW

4.62 kW

El input

1.04 kW

1.62 kW

COP

4.98

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

167 %

Prated

11.80 kW

11.43 kW

SCOP

6.30

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.80 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.62 kW

7.90 kW

COP Tj = +7°C

5.37

3.61

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

11.80 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2504 kWh

3603 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

114 %

Prated

9.49 kW

8.87 kW

SCOP

3.87

2.93

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Pdh Tj = +2°C

7.25 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Pdh Tj = +7°C

5.48 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

6.14

Pdh Tj = Tbiv

8.25 kW

7.71 kW

COP Tj = Tbiv

2.36

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.48 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.49 kW

8.87 kW

Annual energy consumption Qhe

6039 kWh

7456 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.25

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.53 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.68 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4562 kWh

5389 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

111 %

COP

2.55

Heating up time

01:48 h:min

Standby power input

66.0 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

266 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

76 %

COP

1.77

Heating up time

02:34 h:min

Standby power input

83.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

269 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

92 %

COP

2.15

Heating up time

02:12 h:min

Standby power input

68.0 W

Reference hot water temperature

53.2 °C

Mixed water at 40°C

265 l

Bosch CS7001iAW 13 ORB-T
Configure model
Model name
Bosch CS7001iAW 13 ORB-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.19 kW

4.62 kW

El input

1.04 kW

1.62 kW

COP

4.98

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

167 %

Prated

11.80 kW

11.43 kW

SCOP

6.30

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.80 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.62 kW

7.90 kW

COP Tj = +7°C

5.37

3.61

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

11.80 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2504 kWh

3603 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

114 %

Prated

9.49 kW

8.87 kW

SCOP

3.87

2.93

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

7.25 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

5.48 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

6.14

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

8.25 kW

7.71 kW

COP Tj = Tbiv

2.36

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.48 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

9.49 kW

8.87 kW

Annual energy consumption Qhe

6039 kWh

7456 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.25

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.53 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.68 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4562 kWh

5389 kWh

Bosch CS7001iAW 13 ORE-T
Configure model
Model name
Bosch CS7001iAW 13 ORE-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.19 kW

4.62 kW

El input

1.04 kW

1.62 kW

COP

4.98

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

167 %

Prated

11.80 kW

11.43 kW

SCOP

6.30

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.80 kW

11.43 kW

COP Tj = +2°C

3.04

2.17

Pdh Tj = +7°C

7.62 kW

7.90 kW

COP Tj = +7°C

5.37

3.61

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

8.25

5.56

Pdh Tj = Tbiv

11.80 kW

11.43 kW

COP Tj = Tbiv

3.04

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

2.17

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2504 kWh

3603 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

114 %

Prated

9.49 kW

8.87 kW

SCOP

3.87

2.93

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.61

2.70

Pdh Tj = +2°C

7.25 kW

6.86 kW

COP Tj = +2°C

4.12

3.23

Pdh Tj = +7°C

5.48 kW

5.19 kW

COP Tj = +7°C

6.35

4.86

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.59

6.14

Pdh Tj = Tbiv

8.25 kW

7.71 kW

COP Tj = Tbiv

2.36

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.48 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.16

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.49 kW

8.87 kW

Annual energy consumption Qhe

6039 kWh

7456 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.25

1.92

COP Tj = -15°C (if TOL<-20°C)

2.61

1.92

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

140 %

Prated

9.97 kW

9.33 kW

SCOP

4.52

3.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.53 kW

8.41 kW

COP Tj = -7°C

2.95

2.21

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

4.04

3.58

Pdh Tj = +7°C

3.68 kW

5.12 kW

COP Tj = +7°C

6.71

4.54

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.94

5.66

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4562 kWh

5389 kWh

Bosch CS7001iAW 13 ORM-S
Configure model
Model name
Bosch CS7001iAW 13 ORM-S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.86 kW

4.60 kW

El input

1.47 kW

1.79 kW

COP

4.68

2.56

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

166 %

Prated

12.10 kW

10.00 kW

SCOP

5.78

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.20 kW

10.02 kW

COP Tj = +2°C

2.73

2.18

Pdh Tj = +7°C

7.77 kW

6.46 kW

COP Tj = +7°C

4.99

3.73

Pdh Tj = 12°C

3.46 kW

6.17 kW

COP Tj = 12°C

7.51

5.41

Pdh Tj = Tbiv

12.20 kW

10.02 kW

COP Tj = Tbiv

2.73

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.20 kW

10.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.18

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2796 kWh

3154 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

121 %

Prated

9.80 kW

10.60 kW

SCOP

4.19

3.11

Tbiv

-17 °C

-15 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

6.24 kW

6.49 kW

COP Tj = -7°C

3.56

2.65

Pdh Tj = +2°C

3.66 kW

4.49 kW

COP Tj = +2°C

5.14

3.88

Pdh Tj = +7°C

2.82 kW

5.35 kW

COP Tj = +7°C

6.30

4.87

Pdh Tj = 12°C

3.06 kW

6.32 kW

COP Tj = 12°C

6.86

6.09

Pdh Tj = Tbiv

8.60 kW

8.70 kW

COP Tj = Tbiv

2.24

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

8.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.80 kW

10.60 kW

Annual energy consumption Qhe

5762 kWh

8402 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.38

1.83

COP Tj = -15°C (if TOL<-20°C)

2.44

1.83

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

139 %

Prated

10.40 kW

8.60 kW

SCOP

4.73

3.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.07 kW

7.72 kW

COP Tj = -7°C

2.88

2.28

Pdh Tj = +2°C

5.93 kW

4.45 kW

COP Tj = +2°C

4.65

3.53

Pdh Tj = +7°C

3.75 kW

5.21 kW

COP Tj = +7°C

6.29

4.41

Pdh Tj = 12°C

3.11 kW

6.23 kW

COP Tj = 12°C

7.25

5.75

Pdh Tj = Tbiv

10.45 kW

8.59 kW

COP Tj = Tbiv

2.51

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.45 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.89

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4540 kWh

5008 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.52

Heating up time

01:46 h:min

Standby power input

55.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

267 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

82 %

COP

1.91

Heating up time

02:41 h:min

Standby power input

74.0 W

Reference hot water temperature

53.5 °C

Mixed water at 40°C

270 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.13

Heating up time

02:18 h:min

Standby power input

60.0 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

266 l

Bosch CS7001iAW 13 ORMS-S
Configure model
Model name
Bosch CS7001iAW 13 ORMS-S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.86 kW

4.60 kW

El input

1.47 kW

1.79 kW

COP

4.68

2.56

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

166 %

Prated

12.10 kW

10.00 kW

SCOP

5.78

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.20 kW

10.02 kW

COP Tj = +2°C

2.73

2.18

Pdh Tj = +7°C

7.77 kW

6.46 kW

COP Tj = +7°C

4.99

3.73

Pdh Tj = 12°C

3.46 kW

6.17 kW

COP Tj = 12°C

7.51

5.41

Pdh Tj = Tbiv

12.20 kW

10.02 kW

COP Tj = Tbiv

2.73

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.20 kW

10.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.18

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2796 kWh

3154 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

121 %

Prated

9.80 kW

10.60 kW

SCOP

4.19

3.11

Tbiv

-17 °C

-15 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

6.24 kW

6.49 kW

COP Tj = -7°C

3.56

2.65

Pdh Tj = +2°C

3.66 kW

4.49 kW

COP Tj = +2°C

5.14

3.88

Pdh Tj = +7°C

2.82 kW

5.35 kW

COP Tj = +7°C

6.30

4.87

Pdh Tj = 12°C

3.06 kW

6.32 kW

COP Tj = 12°C

6.86

6.09

Pdh Tj = Tbiv

8.60 kW

8.70 kW

COP Tj = Tbiv

2.24

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

8.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.80 kW

10.60 kW

Annual energy consumption Qhe

5762 kWh

8402 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.38

1.83

COP Tj = -15°C (if TOL<-20°C)

2.44

1.83

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

26 dB(A)

26 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

139 %

Prated

10.40 kW

8.60 kW

SCOP

4.73

3.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.07 kW

7.72 kW

COP Tj = -7°C

2.88

2.28

Pdh Tj = +2°C

5.93 kW

4.45 kW

COP Tj = +2°C

4.65

3.53

Pdh Tj = +7°C

3.75 kW

5.21 kW

COP Tj = +7°C

6.29

4.41

Pdh Tj = 12°C

3.11 kW

6.23 kW

COP Tj = 12°C

7.25

5.75

Pdh Tj = Tbiv

10.45 kW

8.59 kW

COP Tj = Tbiv

2.51

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.45 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.89

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4540 kWh

5008 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

100 %

COP

2.32

Heating up time

01:48 h:min

Standby power input

57.0 W

Reference hot water temperature

51.6 °C

Mixed water at 40°C

253 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

80 %

COP

1.87

Heating up time

02:43 h:min

Standby power input

84.0 W

Reference hot water temperature

52.3 °C

Mixed water at 40°C

258 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

89 %

COP

2.09

Heating up time

02:21 h:min

Standby power input

63.0 W

Reference hot water temperature

51.9 °C

Mixed water at 40°C

256 l

Bosch CS7001iAW 13 ORE-S
Configure model
Model name
Bosch CS7001iAW 13 ORE-S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.86 kW

4.60 kW

El input

1.47 kW

1.79 kW

COP

4.68

2.56

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

166 %

Prated

12.10 kW

10.00 kW

SCOP

5.78

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.20 kW

10.02 kW

COP Tj = +2°C

2.73

2.18

Pdh Tj = +7°C

7.77 kW

6.46 kW

COP Tj = +7°C

4.99

3.73

Pdh Tj = 12°C

3.46 kW

6.17 kW

COP Tj = 12°C

7.51

5.41

Pdh Tj = Tbiv

12.20 kW

10.02 kW

COP Tj = Tbiv

2.73

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.20 kW

10.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.18

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2796 kWh

3154 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

121 %

Prated

9.80 kW

10.60 kW

SCOP

4.19

3.11

Tbiv

-17 °C

-15 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

6.24 kW

6.49 kW

COP Tj = -7°C

3.56

2.65

Pdh Tj = +2°C

3.66 kW

4.49 kW

COP Tj = +2°C

5.14

3.88

Pdh Tj = +7°C

2.82 kW

5.35 kW

COP Tj = +7°C

6.30

4.87

Pdh Tj = 12°C

3.06 kW

6.32 kW

COP Tj = 12°C

6.86

6.09

Pdh Tj = Tbiv

8.60 kW

8.70 kW

COP Tj = Tbiv

2.24

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

8.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.69

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.80 kW

10.60 kW

Annual energy consumption Qhe

5762 kWh

8402 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.38

1.83

COP Tj = -15°C (if TOL<-20°C)

2.44

1.83

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

139 %

Prated

10.40 kW

8.60 kW

SCOP

4.73

3.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.07 kW

7.72 kW

COP Tj = -7°C

2.88

2.28

Pdh Tj = +2°C

5.93 kW

4.45 kW

COP Tj = +2°C

4.65

3.53

Pdh Tj = +7°C

3.75 kW

5.21 kW

COP Tj = +7°C

6.29

4.41

Pdh Tj = 12°C

3.11 kW

6.23 kW

COP Tj = 12°C

7.25

5.75

Pdh Tj = Tbiv

10.45 kW

8.59 kW

COP Tj = Tbiv

2.51

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.45 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.89

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4540 kWh

5008 kWh

Bosch CS7001iAW 13 ORB-S
Configure model
Model name
Bosch CS7001iAW 13 ORB-S
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.86 kW

4.60 kW

El input

1.47 kW

1.79 kW

COP

4.68

2.56

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

166 %

Prated

12.10 kW

10.00 kW

SCOP

5.78

4.24

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.20 kW

10.02 kW

COP Tj = +2°C

2.73

2.18

Pdh Tj = +7°C

7.77 kW

6.46 kW

COP Tj = +7°C

4.99

3.73

Pdh Tj = 12°C

3.46 kW

6.17 kW

COP Tj = 12°C

7.51

5.41

Pdh Tj = Tbiv

12.20 kW

10.02 kW

COP Tj = Tbiv

2.73

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.20 kW

10.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.18

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2796 kWh

3154 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

121 %

Prated

9.80 kW

10.60 kW

SCOP

4.19

3.11

Tbiv

-17 °C

-15 °C

TOL

-20 °C

-17 °C

Pdh Tj = -7°C

6.24 kW

6.49 kW

COP Tj = -7°C

3.56

2.65

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

3.66 kW

4.49 kW

COP Tj = +2°C

5.14

3.88

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

2.82 kW

5.35 kW

COP Tj = +7°C

6.30

4.87

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

3.06 kW

6.32 kW

COP Tj = 12°C

6.86

6.09

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

8.60 kW

8.70 kW

COP Tj = Tbiv

2.24

1.83

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

8.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

9.80 kW

10.60 kW

Annual energy consumption Qhe

5762 kWh

8402 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.38

1.83

COP Tj = -15°C (if TOL<-20°C)

2.44

1.83

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

139 %

Prated

10.40 kW

8.60 kW

SCOP

4.73

3.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.07 kW

7.72 kW

COP Tj = -7°C

2.88

2.28

Pdh Tj = +2°C

5.93 kW

4.45 kW

COP Tj = +2°C

4.65

3.53

Pdh Tj = +7°C

3.75 kW

5.21 kW

COP Tj = +7°C

6.29

4.41

Pdh Tj = 12°C

3.11 kW

6.23 kW

COP Tj = 12°C

7.25

5.75

Pdh Tj = Tbiv

10.45 kW

8.59 kW

COP Tj = Tbiv

2.51

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.45 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.89

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4540 kWh

5008 kWh

Bosch CS7001iAW 13 ORMB-T
Configure model
Model name
Bosch CS7001iAW 13 ORMB-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.19 kW

4.62 kW

El input

1.09 kW

1.65 kW

COP

4.76

2.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

233 %

161 %

Prated

11.80 kW

11.43 kW

SCOP

5.90

4.10

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.80 kW

11.43 kW

COP Tj = +2°C

2.98

2.14

Pdh Tj = +7°C

7.62 kW

7.90 kW

COP Tj = +7°C

5.11

3.54

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

7.61

5.38

Pdh Tj = Tbiv

11.80 kW

11.43 kW

COP Tj = Tbiv

2.98

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.14

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2673 kWh

3720 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

145 %

112 %

Prated

9.49 kW

8.88 kW

SCOP

3.71

2.87

Tbiv

-17 °C

-17 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.49

2.65

Pdh Tj = +2°C

7.25 kW

6.86 kW

COP Tj = +2°C

3.95

3.16

Pdh Tj = +7°C

5.48 kW

5.19 kW

COP Tj = +7°C

6.00

4.71

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.04

5.92

Pdh Tj = Tbiv

8.25 kW

7.71 kW

COP Tj = Tbiv

2.30

1.70

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.48 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.11

1.67

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.49 kW

8.88 kW

Annual energy consumption Qhe

6307 kWh

7636 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.80

7.29

COP Tj = -15°C (if TOL<-20°C)

2.54

1.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

137 %

Prated

9.97 kW

9.26 kW

SCOP

4.31

3.49

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.53 kW

8.41 kW

COP Tj = -7°C

2.89

2.18

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

3.88

3.50

Pdh Tj = +7°C

3.68 kW

5.12 kW

COP Tj = +7°C

6.30

4.42

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.35

5.51

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.54

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.82

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4776 kWh

5484 kWh

Bosch CS7000iAW 13 IRMB-T
Configure model
Model name
Bosch CS7000iAW 13 IRMB-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.67 kW

4.39 kW

El input

0.98 kW

1.66 kW

COP

4.77

2.64

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

233 %

158 %

Prated

10.87 kW

11.43 kW

SCOP

5.89

4.02

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.87 kW

11.43 kW

COP Tj = +2°C

2.98

2.14

Pdh Tj = +7°C

7.30 kW

7.90 kW

COP Tj = +7°C

5.10

3.38

Pdh Tj = 12°C

3.13 kW

6.01 kW

COP Tj = 12°C

7.61

5.38

Pdh Tj = Tbiv

10.87 kW

11.43 kW

COP Tj = Tbiv

2.98

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.87 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.14

WTOL

60 °C

60 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

12 W

12 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2466 kWh

3799 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

143 %

111 %

Prated

9.05 kW

9.15 kW

SCOP

3.64

2.84

Tbiv

-17 °C

-16 °C

TOL

-18 °C

-17 °C

Pdh Tj = -7°C

5.98 kW

5.62 kW

COP Tj = -7°C

3.49

2.66

Pdh Tj = +2°C

5.40 kW

6.86 kW

COP Tj = +2°C

3.97

3.17

Pdh Tj = +7°C

2.77 kW

5.19 kW

COP Tj = +7°C

5.95

4.72

Pdh Tj = 12°C

3.07 kW

6.14 kW

COP Tj = 12°C

7.04

5.70

Pdh Tj = Tbiv

7.39 kW

7.71 kW

COP Tj = Tbiv

2.07

1.70

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.18 kW

6.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.12

1.67

WTOL

60 °C

60 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

12 W

12 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.05 kW

9.15 kW

Annual energy consumption Qhe

6132 kWh

7938 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.80

7.29

COP Tj = -15°C (if TOL<-20°C)

2.54

1.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

37 dB(A)

37 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

136 %

Prated

9.97 kW

9.33 kW

SCOP

4.32

3.48

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.14 kW

8.41 kW

COP Tj = -7°C

2.88

2.18

Pdh Tj = +2°C

5.48 kW

4.74 kW

COP Tj = +2°C

3.89

3.50

Pdh Tj = +7°C

3.54 kW

5.12 kW

COP Tj = +7°C

6.30

4.41

Pdh Tj = 12°C

3.11 kW

6.10 kW

COP Tj = 12°C

7.35

5.47

Pdh Tj = Tbiv

9.97 kW

9.33 kW

COP Tj = Tbiv

2.54

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.97 kW

9.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.82

WTOL

60 °C

60 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

12 W

12 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4766 kWh

5534 kWh

Bosch CS7001i AW 13 O TH
Configure model
Model name
Bosch CS7001i AW 13 O TH
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.18 kW

7.41 kW

El input

1.06 kW

2.61 kW

COP

4.89

2.84

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

24 dB(A)

24 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

161 %

Prated

11.80 kW

11.40 kW

SCOP

6.00

4.11

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.80 kW

11.43 kW

COP Tj = +2°C

2.97

2.08

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.71 kW

7.96 kW

COP Tj = +7°C

5.04

3.53

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

3.21 kW

5.96 kW

COP Tj = 12°C

8.31

5.57

Cdh Tj = +12 °C

1.000

0.970

Pdh Tj = Tbiv

11.80 kW

11.43 kW

COP Tj = Tbiv

2.97

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.97

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

27 W

27 W

PSB

26 W

26 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2628 kWh

3705 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

24 dB(A)

24 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

168 %

119 %

Prated

9.50 kW

8.90 kW

SCOP

4.16

3.05

Tbiv

-17 °C

-12 °C

TOL

-20 °C

-18 °C

Pdh Tj = -7°C

5.79 kW

5.78 kW

COP Tj = -7°C

3.72

2.68

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.50 kW

3.83 kW

COP Tj = +2°C

4.89

3.28

Cdh Tj = +2 °C

1.000

0.980

Pdh Tj = +7°C

2.77 kW

5.23 kW

COP Tj = +7°C

7.49

4.71

Cdh Tj = +7 °C

0.930

0.980

Pdh Tj = 12°C

3.20 kW

6.11 kW

COP Tj = 12°C

8.18

6.04

Cdh Tj = +12 °C

0.930

0.970

Pdh Tj = Tbiv

8.55 kW

6.42 kW

COP Tj = Tbiv

2.25

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.86 kW

5.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

27 W

27 W

PSB

26 W

26 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Gas

Gas

Supplementary Heater: PSUP

9.50 kW

8.90 kW

Annual energy consumption Qhe

5487 kWh

7194 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.31

 

COP Tj = -15°C (if TOL<-20°C)

2.46

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

24 dB(A)

24 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

136 %

Prated

10.00 kW

9.30 kW

SCOP

4.92

3.47

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.31 kW

8.39 kW

COP Tj = -7°C

3.00

2.15

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

5.17 kW

4.65 kW

COP Tj = +2°C

4.88

3.48

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

3.70 kW

5.06 kW

COP Tj = +7°C

6.56

4.46

Cdh Tj = +7 °C

1.000

0.980

Pdh Tj = 12°C

3.22 kW

6.05 kW

COP Tj = 12°C

8.28

5.81

Cdh Tj = +12 °C

0.930

0.970

Pdh Tj = Tbiv

10.23 kW

8.39 kW

COP Tj = Tbiv

2.60

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.23 kW

6.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

11 W

11 W

PTO

27 W

27 W

PSB

26 W

26 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

Gas

Supplementary Heater: PSUP

0.00 kW

2.97 kW

Annual energy consumption Qhe

4198 kWh

5535 kWh