Certificate holders

Subtype

Hi-Therma Split 8kW with 260L tank

Certificate Holder
Qingdao Hisense Hitachi Air-conditioning Systems Co.,Ltd.
Qianwangang Road
266555 Qingdao, Shandong
China
Registration number
041-k021-08
Certification Body
BRE Global Limited
Subtype title
Hi-Therma Split 8kW with 260L tank
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,050 kg

Certification Date
20.03.2023
Testing basis
Heat-pump Keymark Scheme rules v11
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

AHW-080HCDS1+AHM-080HCDSAA/HDHWT-300L30H**
Configure model
Model name
AHW-080HCDS1+AHM-080HCDSAA/HDHWT-300L30H**
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.14 kW

8.06 kW

El input

1.64 kW

2.79 kW

COP

4.96

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

134 %

Prated

6.54 kW

5.88 kW

SCOP

4.92

3.42

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.76 kW

5.17 kW

COP Tj = -7°C

3.14

1.85

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.52 kW

3.16 kW

COP Tj = +2°C

4.84

3.40

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.32 kW

2.15 kW

COP Tj = +7°C

5.98

4.50

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.98 kW

2.14 kW

COP Tj = 12°C

9.67

7.71

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.76 kW

5.17 kW

COP Tj = Tbiv

3.14

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.16 kW

5.67 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.66

1.54

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

10 W

10 W

PTO

11 W

11 W

PSB

10 W

10 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.37 kW

0.20 kW

Annual energy consumption Qhe

2732 kWh

3536 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

137 %

COP

3.36

Heating up time

2:24 h:min

Standby power input

27.0 W

Reference hot water temperature

47.0 °C

Mixed water at 40°C

280 l