0,980 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.40 kW
4.49 kW
El input
0.83 kW
1.60 kW
COP
5.30
2.81
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
197 %
126 %
Prated
4.44 kW
3.87 kW
SCOP
5.00
3.23
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.90 kW
3.40 kW
COP Tj = -7°C
3.29
1.97
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.39 kW
2.13 kW
COP Tj = +2°C
4.80
3.22
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.65 kW
1.41 kW
COP Tj = +7°C
6.44
3.97
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.22 kW
2.04 kW
COP Tj = 12°C
9.92
7.24
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
3.90 kW
3.40 kW
COP Tj = Tbiv
3.29
1.97
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.31 kW
3.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.62
1.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
11 W
11 W
PSB
10 W
10 W
PCK
1 W
1 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.13 kW
0.32 kW
Annual energy consumption Qhe
1824 kWh
2457 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
137 %
COP
3.33
Heating up time
2:24 h:min
Standby power input
28.0 W
Reference hot water temperature
47.0 °C
Mixed water at 40°C
280 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.85 kW
6.17 kW
El input
1.22 kW
1.93 kW
COP
4.80
3.19
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
62 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
194 %
130 %
Prated
6.09 kW
5.37 kW
SCOP
4.93
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.36 kW
4.72 kW
COP Tj = -7°C
3.13
2.04
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.25 kW
2.95 kW
COP Tj = +2°C
4.67
3.21
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.00 kW
1.97 kW
COP Tj = +7°C
6.63
4.34
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.22 kW
2.04 kW
COP Tj = 12°C
9.92
7.24
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.36 kW
4.72 kW
COP Tj = Tbiv
3.13
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.32 kW
4.53 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.66
1.75
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
11 W
11 W
PSB
10 W
10 W
PCK
1 W
1 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.74 kW
0.81 kW
Annual energy consumption Qhe
2539 kWh
3312 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
137 %
COP
3.33
Heating up time
2:24 h:min
Standby power input
28.0 W
Reference hot water temperature
47.0 °C
Mixed water at 40°C
280 l