Certificate holders

Subtype

Hi-Therma Split 4 6kW with 185L tank

Certificate Holder
Qingdao Hisense Hitachi Air-conditioning Systems Co.,Ltd.
Qianwangang Road
266555 Qingdao, Shandong
China
Registration number
041-k021-05
Certification Body
BRE Global Limited
Subtype title
Hi-Therma Split 4 6kW with 185L tank
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

0,980 kg

Certification Date
20.03.2023
Testing basis
Heat-pump Keymark Scheme rules v11
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

AHW-044HCDS1+AHM-044HCDSAA/HDHWT-200L30H**
Configure model
Model name
AHW-044HCDS1+AHM-044HCDSAA/HDHWT-200L30H**
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.40 kW

4.49 kW

El input

0.83 kW

1.60 kW

COP

5.30

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

126 %

Prated

4.44 kW

3.87 kW

SCOP

5.00

3.23

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.90 kW

3.40 kW

COP Tj = -7°C

3.29

1.97

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.39 kW

2.13 kW

COP Tj = +2°C

4.80

3.22

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.65 kW

1.41 kW

COP Tj = +7°C

6.44

3.97

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.22 kW

2.04 kW

COP Tj = 12°C

9.92

7.24

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.90 kW

3.40 kW

COP Tj = Tbiv

3.29

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.31 kW

3.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.62

1.68

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

10 W

10 W

PTO

11 W

11 W

PSB

10 W

10 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.13 kW

0.32 kW

Annual energy consumption Qhe

1824 kWh

2457 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

125 %

COP

3.03

Heating up time

1:52 h:min

Standby power input

20.0 W

Reference hot water temperature

47.5 °C

Mixed water at 40°C

190 l

AHW-060HCDS1+AHM-060HCDSAA/HDHWT-200L30H**
Configure model
Model name
AHW-060HCDS1+AHM-060HCDSAA/HDHWT-200L30H**
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.85 kW

6.17 kW

El input

1.22 kW

1.93 kW

COP

4.80

3.19

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

130 %

Prated

6.09 kW

5.37 kW

SCOP

4.93

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.36 kW

4.72 kW

COP Tj = -7°C

3.13

2.04

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.25 kW

2.95 kW

COP Tj = +2°C

4.67

3.21

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.00 kW

1.97 kW

COP Tj = +7°C

6.63

4.34

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.22 kW

2.04 kW

COP Tj = 12°C

9.92

7.24

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.36 kW

4.72 kW

COP Tj = Tbiv

3.13

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.32 kW

4.53 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.66

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

10 W

10 W

PTO

11 W

11 W

PSB

10 W

10 W

PCK

1 W

1 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.74 kW

0.81 kW

Annual energy consumption Qhe

2539 kWh

3312 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

125 %

COP

3.03

Heating up time

1:52 h:min

Standby power input

20.0 W

Reference hot water temperature

47.5 °C

Mixed water at 40°C

190 l