Certificate holders

Subtype

Q-ton HP KEYMARK

Certificate Holder
Mitsubishi Heavy Industries Air Conditioning Europe
5 The Square
UB11 1ET Uxbridge, Middlesex
United Kingdom
Registration number
041-K0003-01 / 1
Certification Body
BRE Global Limited
Subtype title
Q-ton HP KEYMARK
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R744
Mass of Refrigerant

8,500 kg

Certification Date
01.09.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Testing laboratory
BRE Limited, UK
Generate PDF Export model CSV Download certificate
  • Number of models 3

Models

ESA30EH-25
Configure model
Model name
ESA30EH-25
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

22.70 kW

kW

El input

8.53 kW

kW

COP

2.66

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

73 dB(A)

dB(A)

EN 14825

Low temperature

Medium temperature

ηs

146 %

%

Prated

27.00 kW

kW

SCOP

3.65

 

Tbiv

-10 °C

°C

TOL

-10 °C

°C

Pdh Tj = -7°C

23.60 kW

kW

COP Tj = -7°C

2.53

 

Cdh Tj = -7 °C

0.980

 

Pdh Tj = +2°C

14.20 kW

kW

COP Tj = +2°C

3.49

 

Cdh Tj = +2 °C

0.980

 

Pdh Tj = +7°C

12.00 kW

kW

COP Tj = +7°C

4.77

 

Cdh Tj = +7 °C

0.980

 

Pdh Tj = 12°C

14.80 kW

kW

COP Tj = 12°C

6.05

 

Cdh Tj = +12 °C

0.980

 

Pdh Tj = Tbiv

26.50 kW

kW

COP Tj = Tbiv

2.43

 

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

26.50 kW

kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

 

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

 

WTOL

52 °C

°C

Poff

47 W

W

PTO

71 W

W

PSB

47 W

W

PCK

20 W

W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

kW

Annual energy consumption Qhe

1909 kWh

kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

114 %

COP

2.85

Heating up time

01:09 h:min

Standby power input

183.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

1647 l

ESA30EH2-25
Configure model
Model name
ESA30EH2-25
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

22.70 kW

kW

El input

8.53 kW

kW

COP

2.66

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

73 dB(A)

dB(A)

EN 14825

Low temperature

Medium temperature

ηs

146 %

%

Prated

27.00 kW

kW

SCOP

3.65

 

Tbiv

-10 °C

°C

TOL

-10 °C

°C

Pdh Tj = -7°C

23.60 kW

kW

COP Tj = -7°C

2.53

 

Cdh Tj = -7 °C

0.980

 

Pdh Tj = +2°C

14.20 kW

kW

COP Tj = +2°C

3.49

 

Cdh Tj = +2 °C

0.980

 

Pdh Tj = +7°C

12.00 kW

kW

COP Tj = +7°C

4.77

 

Cdh Tj = +7 °C

0.980

 

Pdh Tj = 12°C

14.80 kW

kW

COP Tj = 12°C

6.05

 

Cdh Tj = +12 °C

0.980

 

Pdh Tj = Tbiv

26.50 kW

kW

COP Tj = Tbiv

2.43

 

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

26.50 kW

kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

 

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

 

WTOL

52 °C

°C

Poff

47 W

W

PTO

71 W

W

PSB

47 W

W

PCK

20 W

W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

kW

Annual energy consumption Qhe

1909 kWh

kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

114 %

COP

2.85

Heating up time

01:09 h:min

Standby power input

183.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

1647 l

ESA30E-25
Configure model
Model name
ESA30E-25
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Average Climate

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

114 %

COP

2.85

Heating up time

01:09 h:min

Standby power input

183.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

1647 l