Certificate holders

Subtype

Bosch CS3000 AWP 16/19/24

Certificate Holder
Bosch Thermotechnik GmbH
Junkersstraße 20 - 24
73249 Wernau
Germany
Registration number
ICIM-PDC-000179 / 01
Certification Body
ICIM S.p.A.
Subtype title
Bosch CS3000 AWP 16/19/24
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

7,900 kg

Certification Date
04.11.2022
Testing basis
Heat Pump KEYMARK V10
Generate PDF Export model CSV Download certificate
  • Number of models 12

Models

CS3000AWP 16
Configure model
Model name
CS3000AWP 16
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

25.38 kW

23.06 kW

El input

5.81 kW

9.04 kW

COP

4.37

2.55

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

153 %

Prated

20.75 kW

15.97 kW

SCOP

5.39

3.91

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

20.75 kW

15.97 kW

COP Tj = +2°C

3.37

2.08

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

13.85 kW

11.18 kW

COP Tj = +7°C

4.99

3.49

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

14.21 kW

13.51 kW

COP Tj = 12°C

6.72

5.3

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

20.75 kW

15.97 kW

COP Tj = Tbiv

3.37

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.75 kW

15.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.37

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

5147 kWh

5462 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

144 %

106 %

Prated

16.55 kW

17.13 kW

SCOP

3.67

2.73

Tbiv

-15 °C

-12 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

10.54 kW

10.18 kW

COP Tj = -7°C

2.80

2.16

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

10.53 kW

10.09 kW

COP Tj = +2°C

5.01

3.91

Cdh Tj = +2 °C

0.960

0.960

Pdh Tj = +7°C

12.39 kW

11.93 kW

COP Tj = +7°C

5.98

4.95

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

14.30 kW

13.93 kW

COP Tj = 12°C

6.93

6.17

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

13.50 kW

12.62 kW

COP Tj = Tbiv

2.32

1.60

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.14 kW

11.35 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.78

1.45

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

16.55 kW

17.13 kW

Annual energy consumption Qhe

11102 kWh

15484 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.14

11.35

COP Tj = -15°C (if TOL<-20°C)

1.78

1.45

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173 %

127 %

Prated

19.42 kW

16.78 kW

SCOP

4.41

3.24

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

17.18 kW

13.04 kW

COP Tj = -7°C

2.63

1.93

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

11.61 kW

9.50 kW

COP Tj = +2°C

4.63

3.25

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

12.42 kW

11.10 kW

COP Tj = +7°C

5.49

4.40

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

14.75 kW

13.45 kW

COP Tj = 12°C

6.87

6.15

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

17.18 kW

14.20 kW

COP Tj = Tbiv

2.63

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.67 kW

9.15 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.55

1.35

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.76 kW

7.63 kW

Annual energy consumption Qhe

9104 kWh

10709 kWh

CS3000AWP 16 P
Configure model
Model name
CS3000AWP 16 P
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

25.38 kW

23.06 kW

El input

5.81 kW

9.04 kW

COP

4.37

2.55

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

153 %

Prated

20.75 kW

15.97 kW

SCOP

5.39

3.91

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

20.75 kW

15.97 kW

COP Tj = +2°C

3.37

2.08

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

13.85 kW

11.18 kW

COP Tj = +7°C

4.99

3.49

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

14.21 kW

13.51 kW

COP Tj = 12°C

6.72

5.3

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

20.75 kW

15.97 kW

COP Tj = Tbiv

3.37

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.75 kW

15.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.37

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

5147 kWh

5462 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

144 %

106 %

Prated

16.55 kW

17.13 kW

SCOP

3.67

2.73

Tbiv

-15 °C

-12 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

10.54 kW

10.18 kW

COP Tj = -7°C

2.80

2.16

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

10.53 kW

10.09 kW

COP Tj = +2°C

5.01

3.91

Cdh Tj = +2 °C

0.960

0.960

Pdh Tj = +7°C

12.39 kW

11.93 kW

COP Tj = +7°C

5.98

4.95

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

14.30 kW

13.93 kW

COP Tj = 12°C

6.93

6.17

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

13.50 kW

12.62 kW

COP Tj = Tbiv

2.32

1.60

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.14 kW

11.35 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.78

1.45

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

16.55 kW

17.13 kW

Annual energy consumption Qhe

11102 kWh

15484 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.14

11.35

COP Tj = -15°C (if TOL<-20°C)

1.78

1.45

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173 %

127 %

Prated

19.42 kW

16.78 kW

SCOP

4.41

3.24

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

17.18 kW

13.04 kW

COP Tj = -7°C

2.63

1.93

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

11.61 kW

9.50 kW

COP Tj = +2°C

4.63

3.25

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

12.42 kW

11.10 kW

COP Tj = +7°C

5.49

4.40

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

14.75 kW

13.45 kW

COP Tj = 12°C

6.87

6.15

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

17.18 kW

14.20 kW

COP Tj = Tbiv

2.63

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.67 kW

9.15 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.55

1.35

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.76 kW

7.63 kW

Annual energy consumption Qhe

9104 kWh

10709 kWh

CS3000AWP 16 S
Configure model
Model name
CS3000AWP 16 S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

25.38 kW

23.06 kW

El input

5.81 kW

9.04 kW

COP

4.37

2.55

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

153 %

Prated

20.75 kW

15.97 kW

SCOP

5.39

3.91

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

20.75 kW

15.97 kW

COP Tj = +2°C

3.37

2.08

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

13.85 kW

11.18 kW

COP Tj = +7°C

4.99

3.49

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

14.21 kW

13.51 kW

COP Tj = 12°C

6.72

5.3

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

20.75 kW

15.97 kW

COP Tj = Tbiv

3.37

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.75 kW

15.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.37

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

5147 kWh

5462 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

144 %

106 %

Prated

16.55 kW

17.13 kW

SCOP

3.67

2.73

Tbiv

-15 °C

-12 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

10.54 kW

10.18 kW

COP Tj = -7°C

2.80

2.16

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

10.53 kW

10.09 kW

COP Tj = +2°C

5.01

3.91

Cdh Tj = +2 °C

0.960

0.960

Pdh Tj = +7°C

12.39 kW

11.93 kW

COP Tj = +7°C

5.98

4.95

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

14.30 kW

13.93 kW

COP Tj = 12°C

6.93

6.17

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

13.50 kW

12.62 kW

COP Tj = Tbiv

2.32

1.60

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.14 kW

11.35 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.78

1.45

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

16.55 kW

17.13 kW

Annual energy consumption Qhe

11102 kWh

15484 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.14

11.35

COP Tj = -15°C (if TOL<-20°C)

1.78

1.45

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173 %

127 %

Prated

19.42 kW

16.78 kW

SCOP

4.41

3.24

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

17.18 kW

13.04 kW

COP Tj = -7°C

2.63

1.93

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

11.61 kW

9.50 kW

COP Tj = +2°C

4.63

3.25

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

12.42 kW

11.10 kW

COP Tj = +7°C

5.49

4.40

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

14.75 kW

13.45 kW

COP Tj = 12°C

6.87

6.15

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

17.18 kW

14.20 kW

COP Tj = Tbiv

2.63

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.67 kW

9.15 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.55

1.35

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.76 kW

7.63 kW

Annual energy consumption Qhe

9104 kWh

10709 kWh

CS3000AWP 16 MB
Configure model
Model name
CS3000AWP 16 MB
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

25.38 kW

23.06 kW

El input

5.81 kW

9.04 kW

COP

4.37

2.55

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

153 %

Prated

20.75 kW

15.97 kW

SCOP

5.39

3.91

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

20.75 kW

15.97 kW

COP Tj = +2°C

3.37

2.08

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

13.85 kW

11.18 kW

COP Tj = +7°C

4.99

3.49

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

14.21 kW

13.51 kW

COP Tj = 12°C

6.72

5.3

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

20.75 kW

15.97 kW

COP Tj = Tbiv

3.37

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.75 kW

15.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.37

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

5147 kWh

5462 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

144 %

106 %

Prated

16.55 kW

17.13 kW

SCOP

3.67

2.73

Tbiv

-15 °C

-12 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

10.54 kW

10.18 kW

COP Tj = -7°C

2.80

2.16

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

10.53 kW

10.09 kW

COP Tj = +2°C

5.01

3.91

Cdh Tj = +2 °C

0.960

0.960

Pdh Tj = +7°C

12.39 kW

11.93 kW

COP Tj = +7°C

5.98

4.95

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

14.30 kW

13.93 kW

COP Tj = 12°C

6.93

6.17

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

13.50 kW

12.62 kW

COP Tj = Tbiv

2.32

1.60

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.14 kW

11.35 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.78

1.45

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

16.55 kW

17.13 kW

Annual energy consumption Qhe

11102 kWh

15484 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.14

11.35

COP Tj = -15°C (if TOL<-20°C)

1.78

1.45

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173 %

127 %

Prated

19.42 kW

16.78 kW

SCOP

4.41

3.24

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

17.18 kW

13.04 kW

COP Tj = -7°C

2.63

1.93

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

11.61 kW

9.50 kW

COP Tj = +2°C

4.63

3.25

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

12.42 kW

11.10 kW

COP Tj = +7°C

5.49

4.40

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

14.75 kW

13.45 kW

COP Tj = 12°C

6.87

6.15

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

17.18 kW

14.20 kW

COP Tj = Tbiv

2.63

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.67 kW

9.15 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.55

1.35

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.76 kW

7.63 kW

Annual energy consumption Qhe

9104 kWh

10709 kWh

CS3000AWP 19
Configure model
Model name
CS3000AWP 19
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

30 kW

27.7 kW

El input

6.88 kW

11.49 kW

COP

4.36

2.41

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

154 %

Prated

24.4 kW

17.75 kW

SCOP

5.33

3.92

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

24.4 kW

17.75 kW

COP Tj = +2°C

3.28

2.04

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

16.03 kW

11.18 kW

COP Tj = +7°C

4.83

3.49

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

14.26 kW

13.5 kW

COP Tj = 12°C

6.67

5.28

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

24.4 kW

17.75 kW

COP Tj = Tbiv

3.28

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

24.4 kW

17.75 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.28

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

6120 kWh

6042 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

143 %

106 %

Prated

18.75 kW

19.01 kW

SCOP

3.65

2.73

Tbiv

-15 °C

-12 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

10.57 kW

11.35 kW

COP Tj = -7°C

2.78

2.14

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

10.56 kW

10.09 kW

COP Tj = +2°C

4.94

3.91

Cdh Tj = +2 °C

0.960

0.960

Pdh Tj = +7°C

12.43 kW

11.93 kW

COP Tj = +7°C

5.90

4.95

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

14.34 kW

13.93 kW

COP Tj = 12°C

6.87

6.17

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

15.30 kW

14.01 kW

COP Tj = Tbiv

2.28

1.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.17 kW

13.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.76

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

18.75 kW

19.01 kW

Annual energy consumption Qhe

12674 kWh

17151 kWh

Pdh Tj = -15°C (if TOL<-20°C)

12.17

13.07

COP Tj = -15°C (if TOL<-20°C)

1.76

1.49

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

126 %

Prated

22.5 kW

19.53 kW

SCOP

4.36

3.22

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

19.90 kW

15.95 kW

COP Tj = -7°C

2.60

1.94

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

12.43 kW

10.80 kW

COP Tj = +2°C

4.52

3.20

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

12.42 kW

11.47 kW

COP Tj = +7°C

5.46

4.41

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

14.76 kW

13.80 kW

COP Tj = 12°C

6.85

6.14

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

19.90 kW

16.52 kW

COP Tj = Tbiv

2.60

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.28 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.21 kW

9.53 kW

Annual energy consumption Qhe

10646 kWh

12512 kWh

CS3000AWP 19 P
Configure model
Model name
CS3000AWP 19 P
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

30 kW

27.7 kW

El input

6.88 kW

11.49 kW

COP

4.36

2.41

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

154 %

Prated

24.4 kW

17.75 kW

SCOP

5.33

3.92

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

24.4 kW

17.75 kW

COP Tj = +2°C

3.28

2.04

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

16.03 kW

11.18 kW

COP Tj = +7°C

4.83

3.49

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

14.26 kW

13.5 kW

COP Tj = 12°C

6.67

5.28

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

24.4 kW

17.75 kW

COP Tj = Tbiv

3.28

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

24.4 kW

17.75 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.28

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

6120 kWh

6042 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

143 %

106 %

Prated

18.75 kW

19.01 kW

SCOP

3.65

2.73

Tbiv

-15 °C

-12 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

10.57 kW

11.35 kW

COP Tj = -7°C

2.78

2.14

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

10.56 kW

10.09 kW

COP Tj = +2°C

4.94

3.91

Cdh Tj = +2 °C

0.960

0.960

Pdh Tj = +7°C

12.43 kW

11.93 kW

COP Tj = +7°C

5.90

4.95

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

14.34 kW

13.93 kW

COP Tj = 12°C

6.87

6.17

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

15.30 kW

14.01 kW

COP Tj = Tbiv

2.28

1.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.17 kW

13.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.76

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

18.75 kW

19.01 kW

Annual energy consumption Qhe

12674 kWh

17151 kWh

Pdh Tj = -15°C (if TOL<-20°C)

12.17

13.07

COP Tj = -15°C (if TOL<-20°C)

1.76

1.49

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

126 %

Prated

22.5 kW

19.53 kW

SCOP

4.36

3.22

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

19.90 kW

15.95 kW

COP Tj = -7°C

2.60

1.94

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

12.43 kW

10.80 kW

COP Tj = +2°C

4.52

3.20

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

12.42 kW

11.47 kW

COP Tj = +7°C

5.46

4.41

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

14.76 kW

13.80 kW

COP Tj = 12°C

6.85

6.14

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

19.90 kW

16.52 kW

COP Tj = Tbiv

2.60

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.28 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.21 kW

9.53 kW

Annual energy consumption Qhe

10646 kWh

12512 kWh

CS3000AWP 19 S
Configure model
Model name
CS3000AWP 19 S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

30 kW

27.7 kW

El input

6.88 kW

11.49 kW

COP

4.36

2.41

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

154 %

Prated

24.4 kW

17.75 kW

SCOP

5.33

3.92

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

24.4 kW

17.75 kW

COP Tj = +2°C

3.28

2.04

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

16.03 kW

11.18 kW

COP Tj = +7°C

4.83

3.49

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

14.26 kW

13.5 kW

COP Tj = 12°C

6.67

5.28

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

24.4 kW

17.75 kW

COP Tj = Tbiv

3.28

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

24.4 kW

17.75 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.28

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

6120 kWh

6042 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

143 %

106 %

Prated

18.75 kW

19.01 kW

SCOP

3.65

2.73

Tbiv

-15 °C

-12 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

10.57 kW

11.35 kW

COP Tj = -7°C

2.78

2.14

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

10.56 kW

10.09 kW

COP Tj = +2°C

4.94

3.91

Cdh Tj = +2 °C

0.960

0.960

Pdh Tj = +7°C

12.43 kW

11.93 kW

COP Tj = +7°C

5.90

4.95

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

14.34 kW

13.93 kW

COP Tj = 12°C

6.87

6.17

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

15.30 kW

14.01 kW

COP Tj = Tbiv

2.28

1.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.17 kW

13.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.76

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

18.75 kW

19.01 kW

Annual energy consumption Qhe

12674 kWh

17151 kWh

Pdh Tj = -15°C (if TOL<-20°C)

12.17

13.07

COP Tj = -15°C (if TOL<-20°C)

1.76

1.49

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

126 %

Prated

22.5 kW

19.53 kW

SCOP

4.36

3.22

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

19.90 kW

15.95 kW

COP Tj = -7°C

2.60

1.94

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

12.43 kW

10.80 kW

COP Tj = +2°C

4.52

3.20

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

12.42 kW

11.47 kW

COP Tj = +7°C

5.46

4.41

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

14.76 kW

13.80 kW

COP Tj = 12°C

6.85

6.14

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

19.90 kW

16.52 kW

COP Tj = Tbiv

2.60

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.28 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.21 kW

9.53 kW

Annual energy consumption Qhe

10646 kWh

12512 kWh

CS3000AWP 19 MB
Configure model
Model name
CS3000AWP 19 MB
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

30 kW

27.7 kW

El input

6.88 kW

11.49 kW

COP

4.36

2.41

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

154 %

Prated

24.4 kW

17.75 kW

SCOP

5.33

3.92

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

24.4 kW

17.75 kW

COP Tj = +2°C

3.28

2.04

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

16.03 kW

11.18 kW

COP Tj = +7°C

4.83

3.49

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

14.26 kW

13.5 kW

COP Tj = 12°C

6.67

5.28

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

24.4 kW

17.75 kW

COP Tj = Tbiv

3.28

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

24.4 kW

17.75 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.28

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

6120 kWh

6042 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

143 %

106 %

Prated

18.75 kW

19.01 kW

SCOP

3.65

2.73

Tbiv

-15 °C

-12 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

10.57 kW

11.35 kW

COP Tj = -7°C

2.78

2.14

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

10.56 kW

10.09 kW

COP Tj = +2°C

4.94

3.91

Cdh Tj = +2 °C

0.960

0.960

Pdh Tj = +7°C

12.43 kW

11.93 kW

COP Tj = +7°C

5.90

4.95

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

14.34 kW

13.93 kW

COP Tj = 12°C

6.87

6.17

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

15.30 kW

14.01 kW

COP Tj = Tbiv

2.28

1.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.17 kW

13.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.76

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

18.75 kW

19.01 kW

Annual energy consumption Qhe

12674 kWh

17151 kWh

Pdh Tj = -15°C (if TOL<-20°C)

12.17

13.07

COP Tj = -15°C (if TOL<-20°C)

1.76

1.49

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

126 %

Prated

22.5 kW

19.53 kW

SCOP

4.36

3.22

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

19.90 kW

15.95 kW

COP Tj = -7°C

2.60

1.94

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

12.43 kW

10.80 kW

COP Tj = +2°C

4.52

3.20

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

12.42 kW

11.47 kW

COP Tj = +7°C

5.46

4.41

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

14.76 kW

13.80 kW

COP Tj = 12°C

6.85

6.14

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

19.90 kW

16.52 kW

COP Tj = Tbiv

2.60

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.28 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.21 kW

9.53 kW

Annual energy consumption Qhe

10646 kWh

12512 kWh

CS3000AWP 24
Configure model
Model name
CS3000AWP 24
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

35.78 kW

32.64 kW

El input

8.75 kW

14.01 kW

COP

4.09

2.33

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

155 %

Prated

27.9 kW

19.9 kW

SCOP

5.05

3.95

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

27.9 kW

19.9 kW

COP Tj = +2°C

3.08

2.04

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

19.1 kW

12.4 kW

COP Tj = +7°C

4.41

3.48

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

14.34 kW

13.52 kW

COP Tj = 12°C

6.48

5.29

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

27.9 kW

19.9 kW

COP Tj = Tbiv

3.08

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

27.9 kW

19.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

7376 kWh

6734 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

140 %

106 %

Prated

21.57 kW

20.72 kW

SCOP

3.57

2.73

Tbiv

-15 °C

-12 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

11.9 kW

12.58 kW

COP Tj = -7°C

2.7

2.12

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

10.64 kW

10.1 kW

COP Tj = +2°C

4.78

3.9

Cdh Tj = +2 °C

0.96

0.96

Pdh Tj = +7°C

12.5 kW

11.95 kW

COP Tj = +7°C

5.72

4.96

Cdh Tj = +7 °C

0.96

0.96

Pdh Tj = 12°C

14.42 kW

13.93 kW

COP Tj = 12°C

6.69

6.17

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

17.6 kW

15.27 kW

COP Tj = Tbiv

2.22

1.59

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.8 kW

13.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.84

1.47

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

21.57 kW

20.72 kW

Annual energy consumption Qhe

14915 kWh

18714 kWh

Pdh Tj = -15°C (if TOL<-20°C)

13.8

13.86

COP Tj = -15°C (if TOL<-20°C)

1.84

1.47

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

124 %

Prated

25.5 kW

22.97 kW

SCOP

4.31

3.18

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

22.60 kW

18.82 kW

COP Tj = -7°C

2.60

1.89

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

13.25 kW

12.44 kW

COP Tj = +2°C

4.41

3.15

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

12.44 kW

11.48 kW

COP Tj = +7°C

5.44

4.40

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

14.77 kW

13.82 kW

COP Tj = 12°C

6.83

6.12

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

22.60 kW

19.44 kW

COP Tj = Tbiv

2.60

1.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

18.38 kW

11.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

7.17 kW

11.97 kW

Annual energy consumption Qhe

12250 kWh

14935 kWh

CS3000AWP 24 P
Configure model
Model name
CS3000AWP 24 P
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

35.78 kW

32.64 kW

El input

8.75 kW

14.01 kW

COP

4.09

2.33

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

155 %

Prated

27.9 kW

19.9 kW

SCOP

5.05

3.95

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

27.9 kW

19.9 kW

COP Tj = +2°C

3.08

2.04

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

19.1 kW

12.4 kW

COP Tj = +7°C

4.41

3.48

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

14.34 kW

13.52 kW

COP Tj = 12°C

6.48

5.29

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

27.9 kW

19.9 kW

COP Tj = Tbiv

3.08

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

27.9 kW

19.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

7376 kWh

6734 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

140 %

106 %

Prated

21.57 kW

20.72 kW

SCOP

3.57

2.73

Tbiv

-15 °C

-12 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

11.9 kW

12.58 kW

COP Tj = -7°C

2.7

2.12

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

10.64 kW

10.1 kW

COP Tj = +2°C

4.78

3.9

Cdh Tj = +2 °C

0.96

0.96

Pdh Tj = +7°C

12.5 kW

11.95 kW

COP Tj = +7°C

5.72

4.96

Cdh Tj = +7 °C

0.96

0.96

Pdh Tj = 12°C

14.42 kW

13.93 kW

COP Tj = 12°C

6.69

6.17

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

17.6 kW

15.27 kW

COP Tj = Tbiv

2.22

1.59

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.8 kW

13.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.84

1.47

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

21.57 kW

20.72 kW

Annual energy consumption Qhe

14915 kWh

18714 kWh

Pdh Tj = -15°C (if TOL<-20°C)

13.8

13.86

COP Tj = -15°C (if TOL<-20°C)

1.84

1.47

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

124 %

Prated

25.5 kW

22.97 kW

SCOP

4.31

3.18

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

22.60 kW

18.82 kW

COP Tj = -7°C

2.60

1.89

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

13.25 kW

12.44 kW

COP Tj = +2°C

4.41

3.15

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

12.44 kW

11.48 kW

COP Tj = +7°C

5.44

4.40

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

14.77 kW

13.82 kW

COP Tj = 12°C

6.83

6.12

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

22.60 kW

19.44 kW

COP Tj = Tbiv

2.60

1.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

18.38 kW

11.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

7.17 kW

11.97 kW

Annual energy consumption Qhe

12250 kWh

14935 kWh

CS3000AWP 24 S
Configure model
Model name
CS3000AWP 24 S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

35.78 kW

32.64 kW

El input

8.75 kW

14.01 kW

COP

4.09

2.33

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

155 %

Prated

27.9 kW

19.9 kW

SCOP

5.05

3.95

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

27.9 kW

19.9 kW

COP Tj = +2°C

3.08

2.04

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

19.1 kW

12.4 kW

COP Tj = +7°C

4.41

3.48

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

14.34 kW

13.52 kW

COP Tj = 12°C

6.48

5.29

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

27.9 kW

19.9 kW

COP Tj = Tbiv

3.08

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

27.9 kW

19.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

7376 kWh

6734 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

140 %

106 %

Prated

21.57 kW

20.72 kW

SCOP

3.57

2.73

Tbiv

-15 °C

-12 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

11.9 kW

12.58 kW

COP Tj = -7°C

2.7

2.12

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

10.64 kW

10.1 kW

COP Tj = +2°C

4.78

3.9

Cdh Tj = +2 °C

0.96

0.96

Pdh Tj = +7°C

12.5 kW

11.95 kW

COP Tj = +7°C

5.72

4.96

Cdh Tj = +7 °C

0.96

0.96

Pdh Tj = 12°C

14.42 kW

13.93 kW

COP Tj = 12°C

6.69

6.17

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

17.6 kW

15.27 kW

COP Tj = Tbiv

2.22

1.59

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.8 kW

13.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.84

1.47

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

21.57 kW

20.72 kW

Annual energy consumption Qhe

14915 kWh

18714 kWh

Pdh Tj = -15°C (if TOL<-20°C)

13.8

13.86

COP Tj = -15°C (if TOL<-20°C)

1.84

1.47

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

124 %

Prated

25.5 kW

22.97 kW

SCOP

4.31

3.18

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

22.60 kW

18.82 kW

COP Tj = -7°C

2.60

1.89

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

13.25 kW

12.44 kW

COP Tj = +2°C

4.41

3.15

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

12.44 kW

11.48 kW

COP Tj = +7°C

5.44

4.40

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

14.77 kW

13.82 kW

COP Tj = 12°C

6.83

6.12

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

22.60 kW

19.44 kW

COP Tj = Tbiv

2.60

1.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

18.38 kW

11.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

7.17 kW

11.97 kW

Annual energy consumption Qhe

12250 kWh

14935 kWh

CS3000AWP 24 MB
Configure model
Model name
CS3000AWP 24 MB
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

35.78 kW

32.64 kW

El input

8.75 kW

14.01 kW

COP

4.09

2.33

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

155 %

Prated

27.9 kW

19.9 kW

SCOP

5.05

3.95

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

27.9 kW

19.9 kW

COP Tj = +2°C

3.08

2.04

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

19.1 kW

12.4 kW

COP Tj = +7°C

4.41

3.48

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

14.34 kW

13.52 kW

COP Tj = 12°C

6.48

5.29

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

27.9 kW

19.9 kW

COP Tj = Tbiv

3.08

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

27.9 kW

19.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.08

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

7376 kWh

6734 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

140 %

106 %

Prated

21.57 kW

20.72 kW

SCOP

3.57

2.73

Tbiv

-15 °C

-12 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

11.9 kW

12.58 kW

COP Tj = -7°C

2.7

2.12

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

10.64 kW

10.1 kW

COP Tj = +2°C

4.78

3.9

Cdh Tj = +2 °C

0.96

0.96

Pdh Tj = +7°C

12.5 kW

11.95 kW

COP Tj = +7°C

5.72

4.96

Cdh Tj = +7 °C

0.96

0.96

Pdh Tj = 12°C

14.42 kW

13.93 kW

COP Tj = 12°C

6.69

6.17

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

17.6 kW

15.27 kW

COP Tj = Tbiv

2.22

1.59

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.8 kW

13.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.84

1.47

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

21.57 kW

20.72 kW

Annual energy consumption Qhe

14915 kWh

18714 kWh

Pdh Tj = -15°C (if TOL<-20°C)

13.8

13.86

COP Tj = -15°C (if TOL<-20°C)

1.84

1.47

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

-99 dB(A)

-99 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

124 %

Prated

25.5 kW

22.97 kW

SCOP

4.31

3.18

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

22.60 kW

18.82 kW

COP Tj = -7°C

2.60

1.89

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

13.25 kW

12.44 kW

COP Tj = +2°C

4.41

3.15

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

12.44 kW

11.48 kW

COP Tj = +7°C

5.44

4.40

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

14.77 kW

13.82 kW

COP Tj = 12°C

6.83

6.12

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

22.60 kW

19.44 kW

COP Tj = Tbiv

2.60

1.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

18.38 kW

11.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

100 W

100 W

PSB

50 W

50 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

7.17 kW

11.97 kW

Annual energy consumption Qhe

12250 kWh

14935 kWh