Certificate holders

Subtype

Bosch CS5800i/6800iAW 10/12 OR

Certificate Holder
Bosch Thermotechnik GmbH
Junkersstraße 20 - 24
73249 Wernau
Germany
Registration number
011-1W0583
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Bosch CS5800i/6800iAW 10/12 OR
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,700 kg

Certification Date
11.10.2023
Testing basis
HP KEYMARK certification scheme rules V12
Generate PDF Export model CSV
  • Number of models 18

Models

CS5800iAW 10 ORE-T (60°C)
Configure model
Model name
CS5800iAW 10 ORE-T (60°C)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.58 kW

3.49 kW

El input

1.15 kW

1.2 kW

COP

4.84

2.92

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

244 %

171 %

Prated

10.6 kW

9.8 kW

SCOP

6.18

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.58 kW

9.8 kW

COP Tj = +2°C

2.95

2.13

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

6.42 kW

5.97 kW

COP Tj = +7°C

5.23

3.59

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.1 kW

2.86 kW

COP Tj = 12°C

8.39

5.95

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.58 kW

9.8 kW

COP Tj = Tbiv

2.95

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.58 kW

9.8 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.95

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2292 kWh

3017 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

130 %

Prated

10 kW

10 kW

SCOP

4.36

3.33

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.43 kW

5.93 kW

COP Tj = -7°C

3.68

2.67

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.62 kW

3.94 kW

COP Tj = +2°C

5.31

4.08

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.68 kW

2.48 kW

COP Tj = +7°C

6.89

5.35

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

3.05 kW

2.88 kW

COP Tj = 12°C

7.87

6.21

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

8.09 kW

7.75 kW

COP Tj = Tbiv

2.58

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.6 kW

6.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.22

1.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.4 kW

3.69 kW

Annual energy consumption Qhe

5648 kWh

7392 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.09

7.75

COP Tj = -15°C (if TOL<-20°C)

2.58

2.08

Cdh Tj = -15 °C

0.99

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

142 %

Prated

10 kW

10 kW

SCOP

4.77

3.64

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.04 kW

9.32 kW

COP Tj = -7°C

2.68

2.22

Cdh Tj = -7 °C

0.99

1

Pdh Tj = +2°C

5.89 kW

5.47 kW

COP Tj = +2°C

4.84

3.60

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.64 kW

3.41 kW

COP Tj = +7°C

6.16

4.64

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.13 kW

3.01 kW

COP Tj = 12°C

7.92

6.02

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

9.04 kW

9.32 kW

COP Tj = Tbiv

2.68

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.29 kW

8.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.69

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.71 kW

1.23 kW

Annual energy consumption Qhe

4333 kWh

5681 kWh

CS5800iAW 10 ORE-T
Configure model
Model name
CS5800iAW 10 ORE-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.58 kW

3.49 kW

El input

1.15 kW

1.2 kW

COP

4.84

2.92

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

244 %

171 %

Prated

10.6 kW

9.8 kW

SCOP

6.18

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.58 kW

9.8 kW

COP Tj = +2°C

2.95

2.13

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

6.42 kW

5.97 kW

COP Tj = +7°C

5.23

3.59

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.1 kW

2.86 kW

COP Tj = 12°C

8.39

5.95

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.58 kW

9.8 kW

COP Tj = Tbiv

2.95

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.58 kW

9.8 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.95

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2292 kWh

3017 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

130 %

Prated

10 kW

10 kW

SCOP

4.36

3.33

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.43 kW

5.93 kW

COP Tj = -7°C

3.68

2.67

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.62 kW

3.94 kW

COP Tj = +2°C

5.31

4.08

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.68 kW

2.48 kW

COP Tj = +7°C

6.89

5.35

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

3.05 kW

2.88 kW

COP Tj = 12°C

7.87

6.21

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

8.09 kW

7.75 kW

COP Tj = Tbiv

2.58

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.6 kW

6.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.22

1.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.4 kW

3.69 kW

Annual energy consumption Qhe

5648 kWh

7392 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.09

7.75

COP Tj = -15°C (if TOL<-20°C)

2.58

2.08

Cdh Tj = -15 °C

0.99

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

142 %

Prated

10 kW

10 kW

SCOP

4.77

3.64

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.04 kW

9.32 kW

COP Tj = -7°C

2.68

2.22

Cdh Tj = -7 °C

0.99

1

Pdh Tj = +2°C

5.89 kW

5.47 kW

COP Tj = +2°C

4.84

3.60

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.64 kW

3.41 kW

COP Tj = +7°C

6.16

4.64

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.13 kW

3.01 kW

COP Tj = 12°C

7.92

6.02

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

9.04 kW

9.32 kW

COP Tj = Tbiv

2.68

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.29 kW

8.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.69

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.71 kW

1.23 kW

Annual energy consumption Qhe

4333 kWh

5681 kWh

CS6800iAW 10 ORE-T
Configure model
Model name
CS6800iAW 10 ORE-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.58 kW

3.49 kW

El input

1.15 kW

1.2 kW

COP

4.84

2.92

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

244 %

171 %

Prated

10.6 kW

9.8 kW

SCOP

6.18

4.34

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.58 kW

9.8 kW

COP Tj = +2°C

2.95

2.13

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

6.42 kW

5.97 kW

COP Tj = +7°C

5.23

3.59

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.1 kW

2.86 kW

COP Tj = 12°C

8.39

5.95

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.58 kW

9.8 kW

COP Tj = Tbiv

2.95

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.58 kW

9.8 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.95

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2292 kWh

3017 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

130 %

Prated

10 kW

10 kW

SCOP

4.36

3.33

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.43 kW

5.93 kW

COP Tj = -7°C

3.68

2.67

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.62 kW

3.94 kW

COP Tj = +2°C

5.31

4.08

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.68 kW

2.48 kW

COP Tj = +7°C

6.89

5.35

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

3.05 kW

2.88 kW

COP Tj = 12°C

7.87

6.21

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

8.09 kW

7.75 kW

COP Tj = Tbiv

2.58

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.6 kW

6.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.22

1.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.4 kW

3.69 kW

Annual energy consumption Qhe

5648 kWh

7392 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.09

7.75

COP Tj = -15°C (if TOL<-20°C)

2.58

2.08

Cdh Tj = -15 °C

0.99

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

142 %

Prated

10 kW

10 kW

SCOP

4.77

3.64

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.04 kW

9.32 kW

COP Tj = -7°C

2.68

2.22

Cdh Tj = -7 °C

0.99

1

Pdh Tj = +2°C

5.89 kW

5.47 kW

COP Tj = +2°C

4.84

3.60

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.64 kW

3.41 kW

COP Tj = +7°C

6.16

4.64

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.13 kW

3.01 kW

COP Tj = 12°C

7.92

6.02

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

9.04 kW

9.32 kW

COP Tj = Tbiv

2.68

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.29 kW

8.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.69

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.71 kW

1.23 kW

Annual energy consumption Qhe

4333 kWh

5681 kWh

CS5800iAW 12 ORE-T
Configure model
Model name
CS5800iAW 12 ORE-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.58 kW

4.96 kW

El input

1.15 kW

1.69 kW

COP

4.84

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

235 %

170 %

Prated

12.6 kW

12.4 kW

SCOP

5.95

4.32

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.61 kW

12.43 kW

COP Tj = +2°C

2.64

2.04

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

8.66 kW

7.91 kW

COP Tj = +7°C

5.17

3.67

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.45 kW

3.58 kW

COP Tj = 12°C

8.07

5.84

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

12.61 kW

12.43 kW

COP Tj = Tbiv

2.64

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.61 kW

12.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2829 kWh

3834 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

128 %

Prated

12 kW

12 kW

SCOP

4.24

3.27

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.3 kW

7.07 kW

COP Tj = -7°C

3.6

2.58

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.72 kW

4.36 kW

COP Tj = +2°C

5.42

4.1

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.86 kW

2.59 kW

COP Tj = +7°C

5.35

5.35

Cdh Tj = +7 °C

0.97

0.96

Pdh Tj = 12°C

3.1 kW

2.87 kW

COP Tj = 12°C

8.1

6.09

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.44 kW

9.85 kW

COP Tj = Tbiv

2.37

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.74 kW

7.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.27

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.26 kW

4.98 kW

Annual energy consumption Qhe

6979 kWh

9035 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.44

9.85

COP Tj = -15°C (if TOL<-20°C)

2.37

1.94

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

137 %

Prated

12.2 kW

12 kW

SCOP

4.66

3.51

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.73 kW

11.11 kW

COP Tj = -7°C

2.44

1.91

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.70 kW

6.28 kW

COP Tj = +2°C

4.72

3.60

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.10 kW

4.23 kW

COP Tj = +7°C

6.28

4.48

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.02 kW

3.67 kW

COP Tj = 12°C

8.12

5.99

Cdh Tj = +12 °C

0.95

0.97

Pdh Tj = Tbiv

11.73 kW

11.11 kW

COP Tj = Tbiv

2.44

1.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.82 kW

11.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.38 kW

0.84 kW

Annual energy consumption Qhe

5405 kWh

7071 kWh

CS6800iAW 12 ORE-T
Configure model
Model name
CS6800iAW 12 ORE-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.58 kW

4.96 kW

El input

1.15 kW

1.69 kW

COP

4.84

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

235 %

170 %

Prated

12.6 kW

12.4 kW

SCOP

5.95

4.32

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.61 kW

12.43 kW

COP Tj = +2°C

2.64

2.04

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

8.66 kW

7.91 kW

COP Tj = +7°C

5.17

3.67

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.45 kW

3.58 kW

COP Tj = 12°C

8.07

5.84

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

12.61 kW

12.43 kW

COP Tj = Tbiv

2.64

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.61 kW

12.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2829 kWh

3834 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

128 %

Prated

12 kW

12 kW

SCOP

4.24

3.27

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.3 kW

7.07 kW

COP Tj = -7°C

3.6

2.58

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.72 kW

4.36 kW

COP Tj = +2°C

5.42

4.1

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.86 kW

2.59 kW

COP Tj = +7°C

5.35

5.35

Cdh Tj = +7 °C

0.97

0.96

Pdh Tj = 12°C

3.1 kW

2.87 kW

COP Tj = 12°C

8.1

6.09

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.44 kW

9.85 kW

COP Tj = Tbiv

2.37

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.74 kW

7.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.27

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.26 kW

4.98 kW

Annual energy consumption Qhe

6979 kWh

9035 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.44

9.85

COP Tj = -15°C (if TOL<-20°C)

2.37

1.94

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

137 %

Prated

12.2 kW

12 kW

SCOP

4.66

3.51

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.73 kW

11.11 kW

COP Tj = -7°C

2.44

1.91

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.70 kW

6.28 kW

COP Tj = +2°C

4.72

3.60

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.10 kW

4.23 kW

COP Tj = +7°C

6.28

4.48

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.02 kW

3.67 kW

COP Tj = 12°C

8.12

5.99

Cdh Tj = +12 °C

0.95

0.97

Pdh Tj = Tbiv

11.73 kW

11.11 kW

COP Tj = Tbiv

2.44

1.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.82 kW

11.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.38 kW

0.84 kW

Annual energy consumption Qhe

5405 kWh

7071 kWh

CS5800iAW 12 ORMB-T (60°C)
Configure model
Model name
CS5800iAW 12 ORMB-T (60°C)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.57 kW

4.94 kW

El input

1.16 kW

1.7 kW

COP

4.81

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

234 %

169 %

Prated

12.6 kW

12.4 kW

SCOP

5.91

4.29

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.67 kW

12.42 kW

COP Tj = +2°C

2.66

2.04

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

8.66 kW

7.89 kW

COP Tj = +7°C

5.13

3.66

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.44 kW

3.57 kW

COP Tj = 12°C

8

5.79

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

12.67 kW

12.42 kW

COP Tj = Tbiv

2.66

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.67 kW

12.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.66

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2847 kWh

3859 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

166 %

127 %

Prated

12 kW

12 kW

SCOP

4.21

3.25

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.3 kW

7.05 kW

COP Tj = -7°C

3.58

2.56

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.72 kW

4.35 kW

COP Tj = +2°C

5.38

4.08

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.85 kW

2.57 kW

COP Tj = +7°C

5.3

5.18

Cdh Tj = +7 °C

0.97

0.96

Pdh Tj = 12°C

3.09 kW

2.85 kW

COP Tj = 12°C

8.03

5.93

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.47 kW

9.83 kW

COP Tj = Tbiv

2.35

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.73 kW

7 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.26

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.27 kW

5 kW

Annual energy consumption Qhe

7021 kWh

9107 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.47

9.83

COP Tj = -15°C (if TOL<-20°C)

2.35

1.93

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

136 %

Prated

12.2 kW

12 kW

SCOP

4.64

3.48

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.69 kW

11.10 kW

COP Tj = -7°C

2.45

1.90

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.69 kW

6.27 kW

COP Tj = +2°C

4.69

3.58

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.10 kW

4.22 kW

COP Tj = +7°C

6.24

4.45

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.01 kW

3.65 kW

COP Tj = 12°C

8.05

5.84

Cdh Tj = +12 °C

0.95

0.97

Pdh Tj = Tbiv

11.69 kW

11.10 kW

COP Tj = Tbiv

2.45

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.84 kW

11.14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.36 kW

0.86 kW

Annual energy consumption Qhe

5428 kWh

7114 kWh

CS5800iAW 10 ORMB-T
Configure model
Model name
CS5800iAW 10 ORMB-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.57 kW

3.46 kW

El input

1.16 kW

1.2 kW

COP

4.81

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

243 %

168 %

Prated

10.6 kW

9.8 kW

SCOP

6.14

4.28

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.57 kW

9.78 kW

COP Tj = +2°C

2.98

2.12

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

6.42 kW

5.95 kW

COP Tj = +7°C

5.19

3.57

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.1 kW

2.84 kW

COP Tj = 12°C

8.32

5.8

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.57 kW

9.78 kW

COP Tj = Tbiv

2.98

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.57 kW

9.78 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2306 kWh

3059 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

171 %

129 %

Prated

10 kW

10 kW

SCOP

4.34

3.3

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.42 kW

5.91 kW

COP Tj = -7°C

3.66

2.65

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.61 kW

3.93 kW

COP Tj = +2°C

5.28

4.03

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.67 kW

2.46 kW

COP Tj = +7°C

6.84

5.18

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

3.05 kW

2.86 kW

COP Tj = 12°C

7.81

6.05

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

8.08 kW

7.72 kW

COP Tj = Tbiv

2.57

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.6 kW

6.28 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.21

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.4 kW

3.72 kW

Annual energy consumption Qhe

5681 kWh

7474 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.08

7.72

COP Tj = -15°C (if TOL<-20°C)

2.57

2.07

Cdh Tj = -15 °C

0.99

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

141 %

Prated

10 kW

10 kW

SCOP

4.74

3.61

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.07 kW

9.29 kW

COP Tj = -7°C

2.66

2.21

Cdh Tj = -7 °C

0.99

1

Pdh Tj = +2°C

5.88 kW

5.46 kW

COP Tj = +2°C

4.81

3.58

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.63 kW

3.40 kW

COP Tj = +7°C

6.12

4.58

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.12 kW

2.99 kW

COP Tj = 12°C

7.85

5.87

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

9.07 kW

9.29 kW

COP Tj = Tbiv

2.66

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.29 kW

8.74 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.71 kW

1.26 kW

Annual energy consumption Qhe

4361 kWh

5728 kWh

CS6800iAW 10 ORMB-T
Configure model
Model name
CS6800iAW 10 ORMB-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.57 kW

3.46 kW

El input

1.16 kW

1.2 kW

COP

4.81

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

243 %

168 %

Prated

10.6 kW

9.8 kW

SCOP

6.14

4.28

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.57 kW

9.78 kW

COP Tj = +2°C

2.98

2.12

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

6.42 kW

5.95 kW

COP Tj = +7°C

5.19

3.57

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.1 kW

2.84 kW

COP Tj = 12°C

8.32

5.8

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.57 kW

9.78 kW

COP Tj = Tbiv

2.98

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.57 kW

9.78 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2306 kWh

3059 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

171 %

129 %

Prated

10 kW

10 kW

SCOP

4.34

3.3

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.42 kW

5.91 kW

COP Tj = -7°C

3.66

2.65

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.61 kW

3.93 kW

COP Tj = +2°C

5.28

4.03

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.67 kW

2.46 kW

COP Tj = +7°C

6.84

5.18

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

3.05 kW

2.86 kW

COP Tj = 12°C

7.81

6.05

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

8.08 kW

7.72 kW

COP Tj = Tbiv

2.57

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.6 kW

6.28 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.21

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.4 kW

3.72 kW

Annual energy consumption Qhe

5681 kWh

7474 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.08

7.72

COP Tj = -15°C (if TOL<-20°C)

2.57

2.07

Cdh Tj = -15 °C

0.99

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

141 %

Prated

10 kW

10 kW

SCOP

4.74

3.61

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.07 kW

9.29 kW

COP Tj = -7°C

2.66

2.21

Cdh Tj = -7 °C

0.99

1

Pdh Tj = +2°C

5.88 kW

5.46 kW

COP Tj = +2°C

4.81

3.58

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.63 kW

3.40 kW

COP Tj = +7°C

6.12

4.58

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.12 kW

2.99 kW

COP Tj = 12°C

7.85

5.87

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

9.07 kW

9.29 kW

COP Tj = Tbiv

2.66

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.29 kW

8.74 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.71 kW

1.26 kW

Annual energy consumption Qhe

4361 kWh

5728 kWh

CS5800iAW 12 ORE-T (60°C)
Configure model
Model name
CS5800iAW 12 ORE-T (60°C)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.58 kW

4.96 kW

El input

1.15 kW

1.69 kW

COP

4.84

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

235 %

170 %

Prated

12.6 kW

12.4 kW

SCOP

5.95

4.32

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.61 kW

12.43 kW

COP Tj = +2°C

2.64

2.04

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

8.66 kW

7.91 kW

COP Tj = +7°C

5.17

3.67

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.45 kW

3.58 kW

COP Tj = 12°C

8.07

5.84

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

12.61 kW

12.43 kW

COP Tj = Tbiv

2.64

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.61 kW

12.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2829 kWh

3834 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

128 %

Prated

12 kW

12 kW

SCOP

4.24

3.27

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.3 kW

7.07 kW

COP Tj = -7°C

3.6

2.58

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.72 kW

4.36 kW

COP Tj = +2°C

5.42

4.1

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.86 kW

2.59 kW

COP Tj = +7°C

5.35

5.35

Cdh Tj = +7 °C

0.97

0.96

Pdh Tj = 12°C

3.1 kW

2.87 kW

COP Tj = 12°C

8.1

6.09

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.44 kW

9.85 kW

COP Tj = Tbiv

2.37

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.74 kW

7.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.27

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.26 kW

4.98 kW

Annual energy consumption Qhe

6979 kWh

9035 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.44

9.85

COP Tj = -15°C (if TOL<-20°C)

2.37

1.94

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

31 dB(A)

31 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

137 %

Prated

12.2 kW

12 kW

SCOP

4.66

3.51

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.73 kW

11.11 kW

COP Tj = -7°C

2.44

1.91

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.70 kW

6.28 kW

COP Tj = +2°C

4.72

3.60

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.10 kW

4.23 kW

COP Tj = +7°C

6.28

4.48

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.02 kW

3.67 kW

COP Tj = 12°C

8.12

5.99

Cdh Tj = +12 °C

0.95

0.97

Pdh Tj = Tbiv

11.73 kW

11.11 kW

COP Tj = Tbiv

2.44

1.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.82 kW

11.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.38 kW

0.84 kW

Annual energy consumption Qhe

5405 kWh

7071 kWh

CS5800iAW 10 ORMB-T (60°C)
Configure model
Model name
CS5800iAW 10 ORMB-T (60°C)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.57 kW

3.46 kW

El input

1.16 kW

1.2 kW

COP

4.81

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

243 %

168 %

Prated

10.6 kW

9.8 kW

SCOP

6.14

4.28

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.57 kW

9.78 kW

COP Tj = +2°C

2.98

2.12

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

6.42 kW

5.95 kW

COP Tj = +7°C

5.19

3.57

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.1 kW

2.84 kW

COP Tj = 12°C

8.32

5.8

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.57 kW

9.78 kW

COP Tj = Tbiv

2.98

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.57 kW

9.78 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2306 kWh

3059 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

171 %

129 %

Prated

10 kW

10 kW

SCOP

4.34

3.3

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.42 kW

5.91 kW

COP Tj = -7°C

3.66

2.65

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.61 kW

3.93 kW

COP Tj = +2°C

5.28

4.03

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.67 kW

2.46 kW

COP Tj = +7°C

6.84

5.18

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

3.05 kW

2.86 kW

COP Tj = 12°C

7.81

6.05

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

8.08 kW

7.72 kW

COP Tj = Tbiv

2.57

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.6 kW

6.28 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.21

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.4 kW

3.72 kW

Annual energy consumption Qhe

5681 kWh

7474 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.08

7.72

COP Tj = -15°C (if TOL<-20°C)

2.57

2.07

Cdh Tj = -15 °C

0.99

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

141 %

Prated

10 kW

10 kW

SCOP

4.74

3.61

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.07 kW

9.29 kW

COP Tj = -7°C

2.66

2.21

Cdh Tj = -7 °C

0.99

1

Pdh Tj = +2°C

5.88 kW

5.46 kW

COP Tj = +2°C

4.81

3.58

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.63 kW

3.40 kW

COP Tj = +7°C

6.12

4.58

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.12 kW

2.99 kW

COP Tj = 12°C

7.85

5.87

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

9.07 kW

9.29 kW

COP Tj = Tbiv

2.66

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.29 kW

8.74 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.71 kW

1.26 kW

Annual energy consumption Qhe

4361 kWh

5728 kWh

CS5800iAW 12 ORMB-T
Configure model
Model name
CS5800iAW 12 ORMB-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.57 kW

4.94 kW

El input

1.16 kW

1.7 kW

COP

4.81

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

234 %

169 %

Prated

12.6 kW

12.4 kW

SCOP

5.91

4.29

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.67 kW

12.42 kW

COP Tj = +2°C

2.66

2.04

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

8.66 kW

7.89 kW

COP Tj = +7°C

5.13

3.66

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.44 kW

3.57 kW

COP Tj = 12°C

8

5.79

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

12.67 kW

12.42 kW

COP Tj = Tbiv

2.66

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.67 kW

12.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.66

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2847 kWh

3859 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

166 %

127 %

Prated

12 kW

12 kW

SCOP

4.21

3.25

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.3 kW

7.05 kW

COP Tj = -7°C

3.58

2.56

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.72 kW

4.35 kW

COP Tj = +2°C

5.38

4.08

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.85 kW

2.57 kW

COP Tj = +7°C

5.3

5.18

Cdh Tj = +7 °C

0.97

0.96

Pdh Tj = 12°C

3.09 kW

2.85 kW

COP Tj = 12°C

8.03

5.93

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.47 kW

9.83 kW

COP Tj = Tbiv

2.35

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.73 kW

7 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.26

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.27 kW

5 kW

Annual energy consumption Qhe

7021 kWh

9107 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.47

9.83

COP Tj = -15°C (if TOL<-20°C)

2.35

1.93

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

136 %

Prated

12.2 kW

12 kW

SCOP

4.64

3.48

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.69 kW

11.10 kW

COP Tj = -7°C

2.45

1.90

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.69 kW

6.27 kW

COP Tj = +2°C

4.69

3.58

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.10 kW

4.22 kW

COP Tj = +7°C

6.24

4.45

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.01 kW

3.65 kW

COP Tj = 12°C

8.05

5.84

Cdh Tj = +12 °C

0.95

0.97

Pdh Tj = Tbiv

11.69 kW

11.10 kW

COP Tj = Tbiv

2.45

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.84 kW

11.14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.36 kW

0.86 kW

Annual energy consumption Qhe

5428 kWh

7114 kWh

CS6800iAW 12 ORMB-T
Configure model
Model name
CS6800iAW 12 ORMB-T
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.57 kW

4.94 kW

El input

1.16 kW

1.7 kW

COP

4.81

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

234 %

169 %

Prated

12.6 kW

12.4 kW

SCOP

5.91

4.29

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.67 kW

12.42 kW

COP Tj = +2°C

2.66

2.04

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

8.66 kW

7.89 kW

COP Tj = +7°C

5.13

3.66

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.44 kW

3.57 kW

COP Tj = 12°C

8

5.79

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

12.67 kW

12.42 kW

COP Tj = Tbiv

2.66

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.67 kW

12.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.66

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2847 kWh

3859 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

166 %

127 %

Prated

12 kW

12 kW

SCOP

4.21

3.25

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.3 kW

7.05 kW

COP Tj = -7°C

3.58

2.56

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.72 kW

4.35 kW

COP Tj = +2°C

5.38

4.08

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.85 kW

2.57 kW

COP Tj = +7°C

5.3

5.18

Cdh Tj = +7 °C

0.97

0.96

Pdh Tj = 12°C

3.09 kW

2.85 kW

COP Tj = 12°C

8.03

5.93

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.47 kW

9.83 kW

COP Tj = Tbiv

2.35

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.73 kW

7 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.26

1.64

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.27 kW

5 kW

Annual energy consumption Qhe

7021 kWh

9107 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.47

9.83

COP Tj = -15°C (if TOL<-20°C)

2.35

1.93

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

136 %

Prated

12.2 kW

12 kW

SCOP

4.64

3.48

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.69 kW

11.10 kW

COP Tj = -7°C

2.45

1.90

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.69 kW

6.27 kW

COP Tj = +2°C

4.69

3.58

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.10 kW

4.22 kW

COP Tj = +7°C

6.24

4.45

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.01 kW

3.65 kW

COP Tj = 12°C

8.05

5.84

Cdh Tj = +12 °C

0.95

0.97

Pdh Tj = Tbiv

11.69 kW

11.10 kW

COP Tj = Tbiv

2.45

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.84 kW

11.14 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.36 kW

0.86 kW

Annual energy consumption Qhe

5428 kWh

7114 kWh

CS5800iAW 10 ORM-T (60°C)
Configure model
Model name
CS5800iAW 10 ORM-T (60°C)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.56 kW

3.44 kW

El input

1.16 kW

1.2 kW

COP

4.8

2.86

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

168 %

Prated

10.6 kW

9.8 kW

SCOP

6.14

4.27

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.56 kW

9.76 kW

COP Tj = +2°C

2.98

2.12

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

6.41 kW

5.93 kW

COP Tj = +7°C

5.19

3.56

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.1 kW

2.84 kW

COP Tj = 12°C

8.31

5.79

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.56 kW

9.76 kW

COP Tj = Tbiv

2.98

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.56 kW

9.76 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2308 kWh

3067 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

129 %

Prated

10 kW

10 kW

SCOP

4.34

3.29

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.41 kW

5.89 kW

COP Tj = -7°C

3.66

2.65

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.61 kW

3.92 kW

COP Tj = +2°C

5.27

4.02

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.67 kW

2.45 kW

COP Tj = +7°C

6.83

5.17

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

3.05 kW

2.85 kW

COP Tj = 12°C

7.8

6.04

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

8.08 kW

7.71 kW

COP Tj = Tbiv

2.57

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.59 kW

6.25 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.21

1.71

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.41 kW

3.75 kW

Annual energy consumption Qhe

5685 kWh

7492 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.08

7.71

COP Tj = -15°C (if TOL<-20°C)

2.57

2.06

Cdh Tj = -15 °C

0.99

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

141 %

Prated

10 kW

10 kW

SCOP

4.73

3.6

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.06 kW

9.27 kW

COP Tj = -7°C

2.66

2.20

Cdh Tj = -7 °C

0.99

1

Pdh Tj = +2°C

5.88 kW

5.45 kW

COP Tj = +2°C

4.81

3.58

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.63 kW

3.39 kW

COP Tj = +7°C

6.11

4.57

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.12 kW

2.98 kW

COP Tj = 12°C

7.84

5.86

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

9.06 kW

9.27 kW

COP Tj = Tbiv

2.66

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.28 kW

8.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.72 kW

1.29 kW

Annual energy consumption Qhe

4365 kWh

5742 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.88

Heating up time

2:15 h:min

Standby power input

90 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

83 %

COP

2.02

Heating up time

2:34 h:min

Standby power input

128.6 W

Reference hot water temperature

52.6 °C

Mixed water at 40°C

237 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

95 %

COP

2.33

Heating up time

2:56 h:min

Standby power input

106 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

235 l

CS5800iAW 10 ORM-T
Configure model
Model name
CS5800iAW 10 ORM-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.56 kW

3.44 kW

El input

1.16 kW

1.2 kW

COP

4.8

2.86

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

168 %

Prated

10.6 kW

9.8 kW

SCOP

6.14

4.27

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.56 kW

9.76 kW

COP Tj = +2°C

2.98

2.12

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

6.41 kW

5.93 kW

COP Tj = +7°C

5.19

3.56

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.1 kW

2.84 kW

COP Tj = 12°C

8.31

5.79

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.56 kW

9.76 kW

COP Tj = Tbiv

2.98

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.56 kW

9.76 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2308 kWh

3067 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

129 %

Prated

10 kW

10 kW

SCOP

4.34

3.29

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.41 kW

5.89 kW

COP Tj = -7°C

3.66

2.65

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.61 kW

3.92 kW

COP Tj = +2°C

5.27

4.02

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.67 kW

2.45 kW

COP Tj = +7°C

6.83

5.17

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

3.05 kW

2.85 kW

COP Tj = 12°C

7.8

6.04

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

8.08 kW

7.71 kW

COP Tj = Tbiv

2.57

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.59 kW

6.25 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.21

1.71

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.41 kW

3.75 kW

Annual energy consumption Qhe

5685 kWh

7492 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.08

7.71

COP Tj = -15°C (if TOL<-20°C)

2.57

2.06

Cdh Tj = -15 °C

0.99

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

141 %

Prated

10 kW

10 kW

SCOP

4.73

3.6

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.06 kW

9.27 kW

COP Tj = -7°C

2.66

2.20

Cdh Tj = -7 °C

0.99

1

Pdh Tj = +2°C

5.88 kW

5.45 kW

COP Tj = +2°C

4.81

3.58

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.63 kW

3.39 kW

COP Tj = +7°C

6.11

4.57

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.12 kW

2.98 kW

COP Tj = 12°C

7.84

5.86

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

9.06 kW

9.27 kW

COP Tj = Tbiv

2.66

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.28 kW

8.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.72 kW

1.29 kW

Annual energy consumption Qhe

4365 kWh

5742 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.88

Heating up time

2:15 h:min

Standby power input

90 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

83 %

COP

2.02

Heating up time

2:34 h:min

Standby power input

128.6 W

Reference hot water temperature

52.6 °C

Mixed water at 40°C

237 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

95 %

COP

2.33

Heating up time

2:56 h:min

Standby power input

106 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

235 l

CS6800iAW 10 ORM-T
Configure model
Model name
CS6800iAW 10 ORM-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.56 kW

3.44 kW

El input

1.16 kW

1.2 kW

COP

4.8

2.86

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

242 %

168 %

Prated

10.6 kW

9.8 kW

SCOP

6.14

4.27

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.56 kW

9.76 kW

COP Tj = +2°C

2.98

2.12

Cdh Tj = +2 °C

0.99

1

Pdh Tj = +7°C

6.41 kW

5.93 kW

COP Tj = +7°C

5.19

3.56

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.1 kW

2.84 kW

COP Tj = 12°C

8.31

5.79

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.56 kW

9.76 kW

COP Tj = Tbiv

2.98

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.56 kW

9.76 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2308 kWh

3067 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

129 %

Prated

10 kW

10 kW

SCOP

4.34

3.29

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.41 kW

5.89 kW

COP Tj = -7°C

3.66

2.65

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.61 kW

3.92 kW

COP Tj = +2°C

5.27

4.02

Cdh Tj = +2 °C

0.97

0.98

Pdh Tj = +7°C

2.67 kW

2.45 kW

COP Tj = +7°C

6.83

5.17

Cdh Tj = +7 °C

0.95

0.96

Pdh Tj = 12°C

3.05 kW

2.85 kW

COP Tj = 12°C

7.8

6.04

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

8.08 kW

7.71 kW

COP Tj = Tbiv

2.57

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.59 kW

6.25 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.21

1.71

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.41 kW

3.75 kW

Annual energy consumption Qhe

5685 kWh

7492 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.08

7.71

COP Tj = -15°C (if TOL<-20°C)

2.57

2.06

Cdh Tj = -15 °C

0.99

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

141 %

Prated

10 kW

10 kW

SCOP

4.73

3.6

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.06 kW

9.27 kW

COP Tj = -7°C

2.66

2.20

Cdh Tj = -7 °C

0.99

1

Pdh Tj = +2°C

5.88 kW

5.45 kW

COP Tj = +2°C

4.81

3.58

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.63 kW

3.39 kW

COP Tj = +7°C

6.11

4.57

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.12 kW

2.98 kW

COP Tj = 12°C

7.84

5.86

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

9.06 kW

9.27 kW

COP Tj = Tbiv

2.66

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.28 kW

8.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

34 W

34 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.72 kW

1.29 kW

Annual energy consumption Qhe

4365 kWh

5742 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.88

Heating up time

2:15 h:min

Standby power input

90 W

Reference hot water temperature

52.8 °C

Mixed water at 40°C

239 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

83 %

COP

2.02

Heating up time

2:34 h:min

Standby power input

128.6 W

Reference hot water temperature

52.6 °C

Mixed water at 40°C

237 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

95 %

COP

2.33

Heating up time

2:56 h:min

Standby power input

106 W

Reference hot water temperature

52.7 °C

Mixed water at 40°C

235 l

CS5800iAW 12 ORM-T (60°C)
Configure model
Model name
CS5800iAW 12 ORM-T (60°C)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.56 kW

4.91 kW

El input

1.16 kW

1.7 kW

COP

4.8

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

233 %

168 %

Prated

12.6 kW

12.4 kW

SCOP

5.91

4.28

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.66 kW

12.4 kW

COP Tj = +2°C

2.66

2.03

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

8.66 kW

7.87 kW

COP Tj = +7°C

5.13

3.65

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.44 kW

3.57 kW

COP Tj = 12°C

8

5.78

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

12.66 kW

12.4 kW

COP Tj = Tbiv

2.66

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.66 kW

12.4 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.66

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2848 kWh

3866 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

127 %

Prated

12 kW

12 kW

SCOP

4.21

3.24

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.3 kW

7.03 kW

COP Tj = -7°C

3.58

2.56

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.71 kW

4.34 kW

COP Tj = +2°C

5.38

4.07

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.85 kW

2.56 kW

COP Tj = +7°C

5.3

5.17

Cdh Tj = +7 °C

0.97

0.96

Pdh Tj = 12°C

3.09 kW

2.85 kW

COP Tj = 12°C

8.02

5.92

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.47 kW

9.81 kW

COP Tj = Tbiv

2.35

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.72 kW

6.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.26

1.63

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.28 kW

5.03 kW

Annual energy consumption Qhe

7025 kWh

9125 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.47

9.81

COP Tj = -15°C (if TOL<-20°C)

2.35

1.93

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

136 %

Prated

12.2 kW

12 kW

SCOP

4.64

3.48

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.69 kW

11.07 kW

COP Tj = -7°C

2.45

1.90

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.68 kW

6.25 kW

COP Tj = +2°C

4.68

3.57

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.10 kW

4.21 kW

COP Tj = +7°C

6.24

4.45

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.01 kW

3.64 kW

COP Tj = 12°C

8.04

5.83

Cdh Tj = +12 °C

0.95

0.97

Pdh Tj = Tbiv

11.69 kW

11.07 kW

COP Tj = Tbiv

2.45

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.83 kW

11.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

60 °C

60 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.37 kW

0.89 kW

Annual energy consumption Qhe

5432 kWh

7130 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.87

Heating up time

2:03 h:min

Standby power input

90 W

Reference hot water temperature

53 °C

Mixed water at 40°C

244 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

83 %

COP

1.99

Heating up time

2:24 h:min

Standby power input

170 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

238 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

95 %

COP

2.34

Heating up time

2:12 h:min

Standby power input

100 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

235 l

CS5800iAW 12 ORM-T
Configure model
Model name
CS5800iAW 12 ORM-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.56 kW

4.91 kW

El input

1.16 kW

1.7 kW

COP

4.8

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

233 %

168 %

Prated

12.6 kW

12.4 kW

SCOP

5.91

4.28

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.66 kW

12.4 kW

COP Tj = +2°C

2.66

2.03

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

8.66 kW

7.87 kW

COP Tj = +7°C

5.13

3.65

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.44 kW

3.57 kW

COP Tj = 12°C

8

5.78

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

12.66 kW

12.4 kW

COP Tj = Tbiv

2.66

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.66 kW

12.4 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.66

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2848 kWh

3866 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

127 %

Prated

12 kW

12 kW

SCOP

4.21

3.24

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.3 kW

7.03 kW

COP Tj = -7°C

3.58

2.56

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.71 kW

4.34 kW

COP Tj = +2°C

5.38

4.07

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.85 kW

2.56 kW

COP Tj = +7°C

5.3

5.17

Cdh Tj = +7 °C

0.97

0.96

Pdh Tj = 12°C

3.09 kW

2.85 kW

COP Tj = 12°C

8.02

5.92

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.47 kW

9.81 kW

COP Tj = Tbiv

2.35

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.72 kW

6.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.26

1.63

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.28 kW

5.03 kW

Annual energy consumption Qhe

7025 kWh

9125 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.47

9.81

COP Tj = -15°C (if TOL<-20°C)

2.35

1.93

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

136 %

Prated

12.2 kW

12 kW

SCOP

4.64

3.48

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.69 kW

11.07 kW

COP Tj = -7°C

2.45

1.90

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.68 kW

6.25 kW

COP Tj = +2°C

4.68

3.57

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.10 kW

4.21 kW

COP Tj = +7°C

6.24

4.45

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.01 kW

3.64 kW

COP Tj = 12°C

8.04

5.83

Cdh Tj = +12 °C

0.95

0.97

Pdh Tj = Tbiv

11.69 kW

11.07 kW

COP Tj = Tbiv

2.45

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.83 kW

11.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.37 kW

0.89 kW

Annual energy consumption Qhe

5432 kWh

7130 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.87

Heating up time

2:03 h:min

Standby power input

90 W

Reference hot water temperature

53 °C

Mixed water at 40°C

244 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

83 %

COP

1.99

Heating up time

2:24 h:min

Standby power input

170 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

238 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

95 %

COP

2.34

Heating up time

2:12 h:min

Standby power input

100 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

235 l

CS6800iAW 12 ORM-T
Configure model
Model name
CS6800iAW 12 ORM-T
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.56 kW

4.91 kW

El input

1.16 kW

1.7 kW

COP

4.8

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

233 %

168 %

Prated

12.6 kW

12.4 kW

SCOP

5.91

4.28

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.66 kW

12.4 kW

COP Tj = +2°C

2.66

2.03

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

8.66 kW

7.87 kW

COP Tj = +7°C

5.13

3.65

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.44 kW

3.57 kW

COP Tj = 12°C

8

5.78

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

12.66 kW

12.4 kW

COP Tj = Tbiv

2.66

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.66 kW

12.4 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.66

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2848 kWh

3866 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

127 %

Prated

12 kW

12 kW

SCOP

4.21

3.24

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.3 kW

7.03 kW

COP Tj = -7°C

3.58

2.56

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.71 kW

4.34 kW

COP Tj = +2°C

5.38

4.07

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.85 kW

2.56 kW

COP Tj = +7°C

5.3

5.17

Cdh Tj = +7 °C

0.97

0.96

Pdh Tj = 12°C

3.09 kW

2.85 kW

COP Tj = 12°C

8.02

5.92

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

10.47 kW

9.81 kW

COP Tj = Tbiv

2.35

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.72 kW

6.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.26

1.63

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.28 kW

5.03 kW

Annual energy consumption Qhe

7025 kWh

9125 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.47

9.81

COP Tj = -15°C (if TOL<-20°C)

2.35

1.93

Cdh Tj = -15 °C

1

1

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

45 dB(A)

45 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

136 %

Prated

12.2 kW

12 kW

SCOP

4.64

3.48

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.69 kW

11.07 kW

COP Tj = -7°C

2.45

1.90

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.68 kW

6.25 kW

COP Tj = +2°C

4.68

3.57

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.10 kW

4.21 kW

COP Tj = +7°C

6.24

4.45

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.01 kW

3.64 kW

COP Tj = 12°C

8.04

5.83

Cdh Tj = +12 °C

0.95

0.97

Pdh Tj = Tbiv

11.69 kW

11.07 kW

COP Tj = Tbiv

2.45

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.83 kW

11.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.44

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1

1

WTOL

75 °C

75 °C

Poff

33 W

33 W

PTO

18 W

18 W

PSB

33 W

33 W

PCK

67 W

67 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.37 kW

0.89 kW

Annual energy consumption Qhe

5432 kWh

7130 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.87

Heating up time

2:03 h:min

Standby power input

90 W

Reference hot water temperature

53 °C

Mixed water at 40°C

244 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

83 %

COP

1.99

Heating up time

2:24 h:min

Standby power input

170 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

238 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

95 %

COP

2.34

Heating up time

2:12 h:min

Standby power input

100 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

235 l