Certificate holders

Subtype

NEVIS EVO R32 25/35 UD0-I

Certificate Holder
Ariston Thermo Group
Viale Aristide Merloni 45
I-60044 Fabriano (AN)
Italy
Registration number
ICIM-PDC-000172
Certification Body
ICIM S.p.A.
Subtype title
NEVIS EVO R32 25/35 UD0-I
Driving energy
Electricity
Heat Pump Type
Air/Air Single Split
Refrigerant
R32
Mass of Refrigerant

0,620 kg

Certification Date
31.08.2022
Testing basis
Heat Pump KEYMARK V10
Generate PDF Export model CSV
  • Number of models 2

Models

NEVIS EVO R32 35 UD0-I
Configure model
Model name
NEVIS EVO R32 35 UD0-I
Application
Heating + Cooling
Climate zone (for heating)
n/a
EN14511-2 certification (heating mode)
Yes
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

A7/A20

Heating capacity

3.96

El input

0.99 kW

COP

4.00

Cooling

EN 14511-2

A35/A27

El input

0.93 kW

Cooling capacity

3.52

EER

3.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

EN 12102-1

Sound power level indoor

56 dB(A)

Sound power level outdoor

61 dB(A)

EN 14825

Indoor dry(wet) bulb temperature 27(19)°C

Pdesignc

3.50 kW

SEER

8.50

Pdc Tj = 35°C

3.50 kW

EER Tj = 35°C

3.80

Cdc Tj = 35 °C

0.250

Pdc Tj = 30°C

2.35 kW

EER Tj = 30°C

6.27

Cdc Tj = 30 °C

0.250

Pdc Tj = 25°C

1.06 kW

EER Tj = 25°C

10.07

Cdc Tj = 25 °C

0.250

Pdc Tj = 20°C

1.00 kW

EER Tj = 20°C

17.30

Cdc Tj = 20 °C

0.250

Poff

1 W

PTO

13 W

PSB

1 W

PCK

0 W

Annual energy consumption Qce

144 kWh

Average Climate

EN 14825

Indoor dry bulb temperature: 20°C

Pdesignh

2.60 kW

SCOP

4.60

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

2.30 kW

COP Tj = -7°C

3.25

Cdh Tj = -7 °C

0.250

Pdh Tj = +2°C

1.41 kW

COP Tj = +2°C

4.64

Cdh Tj = +2 °C

0.250

Pdh Tj = +7°C

0.91 kW

COP Tj = +7°C

5.50

Cdh Tj = +7 °C

0.250

Pdh Tj = 12°C

0.68 kW

COP Tj = 12°C

6.61

Cdh Tj = +12 °C

0.250

Pdh Tj = Tbiv

2.30 kW

COP Tj = Tbiv

3.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

Poff

1 W

PTO

15 W

PSB

1 W

PCK

0 W

Backup Heater

0.30 kW

Annual energy consumption Qhe

791 kWh

NEVIS EVO R32 25 UD0-I
Configure model
Model name
NEVIS EVO R32 25 UD0-I
Application
Heating + Cooling
Climate zone (for heating)
n/a
EN14511-2 certification (heating mode)
Yes
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

A7/A20

Heating capacity

3.14

El input

0.68 kW

COP

4.61

Cooling

EN 14511-2

A35/A27

El input

0.62 kW

Cooling capacity

2.73

EER

4.41

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

EN 12102-1

Sound power level indoor

56 dB(A)

Sound power level outdoor

59 dB(A)

EN 14825

Indoor dry(wet) bulb temperature 27(19)°C

Pdesignc

2.70 kW

SEER

9.30

Pdc Tj = 35°C

2.70 kW

EER Tj = 35°C

4.50

Cdc Tj = 35 °C

0.250

Pdc Tj = 30°C

1.81 kW

EER Tj = 30°C

7.26

Cdc Tj = 30 °C

0.250

Pdc Tj = 25°C

1.16 kW

EER Tj = 25°C

11.36

Cdc Tj = 25 °C

0.250

Pdc Tj = 20°C

1.10 kW

EER Tj = 20°C

17.40

Cdc Tj = 20 °C

0.250

Poff

1 W

PTO

13 W

PSB

1 W

PCK

0 W

Annual energy consumption Qce

102 kWh

Average Climate

EN 14825

Indoor dry bulb temperature: 20°C

Pdesignh

2.50 kW

SCOP

4.60

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

2.21 kW

COP Tj = -7°C

3.24

Cdh Tj = -7 °C

0.250

Pdh Tj = +2°C

1.36 kW

COP Tj = +2°C

4.68

Cdh Tj = +2 °C

0.250

Pdh Tj = +7°C

0.88 kW

COP Tj = +7°C

5.45

Cdh Tj = +7 °C

0.250

Pdh Tj = 12°C

0.68 kW

COP Tj = 12°C

6.59

Cdh Tj = +12 °C

0.250

Pdh Tj = Tbiv

2.21 kW

COP Tj = Tbiv

3.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

Poff

1 W

PTO

14 W

PSB

1 W

PCK

0 W

Backup Heater

0.29 kW

Annual energy consumption Qhe

761 kWh