Atlantic Ixtra M 15 Tri

Certificate Holder
Groupe Atlantic
44 boulevard des Etats-Unis
85000 La Roche Sur Yon
France
Registration number
012-C700149
Certification Body
RISE CERT
Subtype title
Atlantic Ixtra M 15 Tri
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R452B
Mass of Refrigerant

2,750 kg

Certification Date
30.06.2022
Testing basis
EN 14511:2018, EN 14825:2016, EN 12102:2017
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Atlantic Ixtra M 15 Tri
Configure model
Model name
Atlantic Ixtra M 15 Tri
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

12.90 kW

El input

1.77 kW

4.31 kW

COP

4.79

2.99

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

131 %

Prated

13.50 kW

13.30 kW

SCOP

4.51

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.90 kW

11.80 kW

COP Tj = -7°C

3.04

2.24

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

7.30 kW

7.20 kW

COP Tj = +2°C

4.70

3.38

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

8.60 kW

8.30 kW

COP Tj = +7°C

5.55

4.24

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

10.10 kW

9.80 kW

COP Tj = 12°C

6.53

5.06

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

11.90 kW

11.80 kW

COP Tj = Tbiv

3.09

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.10 kW

11.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

48 W

32 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.40 kW

2.10 kW

Annual energy consumption Qhe

6187 kWh

8179 kWh