TALIA HYBRID FLEX LINK R32

Certificate Holder
Ariston Thermo Group
Viale Aristide Merloni 45
I-60044 Fabriano (AN)
Italy
Registration number
ICIM-PDC-000195
Certification Body
ICIM S.p.A.
Subtype title
TALIA HYBRID FLEX LINK R32
Driving energy
Hybrid
Heat Pump Type
Hybrid Air/Water
Refrigerant
R32
Mass of Refrigerant

1,000 kg

Certification Date
02.05.2023
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

TALIA HYBRID FLEX LINK R32
Configure model
Model name
TALIA HYBRID FLEX LINK R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.50 kW

2.95 kW

El input

0.69 kW

1.09 kW

COP

5.10

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.03 kW

Cooling capacity

3.50

EER

3.40

EN 14825

+7°C/+12°C

Pdesignc

3.5 kW

SEER

4.87

Pdc Tj = 35°C

3.5 kW

EER Tj = 35°C

3

Pdc Tj = 30°C

2.58 kW

EER Tj = 30°C

4.33

Cdc Tj = 30 °C

0.98

Pdc Tj = 25°C

1.72 kW

EER Tj = 25°C

5.86

Cdc Tj = 25 °C

0.95

Pdc Tj = 20°C

1.79 kW

EER Tj = 20°C

7.24

Cdc Tj = 20 °C

0.94

Poff

14 W

PTO

14 W

PSB

14 W

PCK

0 W

Annual energy consumption Qce

628 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

5.20 kW

4.63 kW

ηs

194 %

134 %

Prated

5.20 kW

4.63 kW

SCOP

4.94

3.43

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.60 kW

4.10 kW

COP Tj = -7°C

3.21

2.28

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.88 kW

2.63 kW

COP Tj = +2°C

4.66

3.35

Cdh Tj = +2 °C

0.980

0.983

Pdh Tj = +7°C

1.85 kW

1.76 kW

COP Tj = +7°C

6.56

4.22

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

1.92 kW

1.88 kW

COP Tj = 12°C

8.49

6.30

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

4.60 kW

4.10 kW

COP Tj = Tbiv

3.21

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.10 kW

3.79 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.993

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

13 W

13 W

Supplementary Heater: Type of energy input

Gas

Electricity

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Backup Heater

4.00 kW

4.00 kW

Annual energy consumption Qhe

2780 kWh

2790 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

128 %

COP

3.00

Heating up time

1:55 h:min

Standby power input

40.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

240 l