1,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.50 kW
2.95 kW
El input
0.69 kW
1.09 kW
COP
5.10
2.70
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
1.03 kW
Cooling capacity
3.50
EER
3.40
EN 14825
+7°C/+12°C
Pdesignc
3.5 kW
SEER
4.87
Pdc Tj = 35°C
3.5 kW
EER Tj = 35°C
3
Pdc Tj = 30°C
2.58 kW
EER Tj = 30°C
4.33
Cdc Tj = 30 °C
0.98
Pdc Tj = 25°C
1.72 kW
EER Tj = 25°C
5.86
Cdc Tj = 25 °C
0.95
Pdc Tj = 20°C
1.79 kW
EER Tj = 20°C
7.24
Cdc Tj = 20 °C
0.94
Poff
14 W
PTO
14 W
PSB
14 W
PCK
0 W
Annual energy consumption Qce
628 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
48 dB(A)
48 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
2.84 kW
2.35 kW
ηs
240 %
137 %
Prated
2.84 kW
2.35 kW
SCOP
6.06
3.49
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
2.84 kW
2.35 kW
COP Tj = +2°C
4.00
2.19
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
1.88 kW
1.60 kW
COP Tj = +7°C
5.57
2.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
1.91 kW
1.81 kW
COP Tj = 12°C
7.94
5.10
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
2.84 kW
2.35 kW
COP Tj = Tbiv
4.00
2.19
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.84 kW
2.35 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.00
2.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.982
0.988
WTOL
60 °C
60 °C
Poff
13 W
13 W
PTO
13 W
13 W
PSB
13 W
13 W
PCK
13 W
13 W
Supplementary Heater: Type of energy input
Gas
Gas
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
626 kWh
899 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
48 dB(A)
48 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
7.75 kW
7.43 kW
ηs
172 %
134 %
Prated
7.75 kW
7.43 kW
SCOP
4.40
3.43
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.69 kW
4.50 kW
COP Tj = -7°C
3.54
2.76
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.95 kW
2.94 kW
COP Tj = +2°C
5.16
3.99
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
1.89 kW
1.92 kW
COP Tj = +7°C
7.19
5.35
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
1.92 kW
1.93 kW
COP Tj = 12°C
8.55
6.96
Cdh Tj = +12 °C
0.942
0.953
Pdh Tj = Tbiv
4.69 kW
4.50 kW
COP Tj = Tbiv
3.54
2.76
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.03 kW
2.46 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.52
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.992
WTOL
60 °C
60 °C
Poff
13 W
13 W
PTO
13 W
13 W
PSB
13 W
13 W
PCK
13 W
13 W
Supplementary Heater: Type of energy input
Gas
Gas
Supplementary Heater: PSUP
7.34 kW
7.04 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
4355 kWh
5337 kWh
Pdh Tj = -15°C (if TOL<-20°C)
COP Tj = -15°C (if TOL<-20°C)
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
48 dB(A)
48 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
5.20 kW
4.63 kW
ηs
194 %
134 %
Prated
5.20 kW
4.63 kW
SCOP
4.94
3.43
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
4.60 kW
4.10 kW
COP Tj = -7°C
3.21
2.28
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.88 kW
2.63 kW
COP Tj = +2°C
4.66
3.35
Cdh Tj = +2 °C
0.980
0.983
Pdh Tj = +7°C
1.85 kW
1.76 kW
COP Tj = +7°C
6.56
4.22
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
1.92 kW
1.88 kW
COP Tj = 12°C
8.49
6.30
Cdh Tj = +12 °C
0.960
0.960
Pdh Tj = Tbiv
4.60 kW
4.10 kW
COP Tj = Tbiv
3.21
2.28
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.10 kW
3.79 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.90
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.991
0.993
WTOL
60 °C
60 °C
Poff
13 W
13 W
PTO
13 W
13 W
PSB
13 W
13 W
PCK
13 W
13 W
Supplementary Heater: Type of energy input
Gas
Gas
Supplementary Heater: PSUP
1.10 kW
0.80 kW
Backup Heater
4.00 kW
4.00 kW
Annual energy consumption Qhe
2188 kWh
2780 kWh