Certificate holders

Subtype

DAIKIN ALTHERMA 3 H HT W/F 14KW (180L)

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0353
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA 3 H HT W/F 14KW (180L)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

4,200 kg

Certification Date
07.02.2020
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 28

Models

EPRA14DV3 / ETBH16E(6V/9W)
Configure model
Model name
EPRA14DV3 / ETBH16E(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

EPRA14DW1 / ETBH16E(6V/9W)
Configure model
Model name
EPRA14DW1 / ETBH16E(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

EPRA14DV3 / ETBX16E(6V/9W)
Configure model
Model name
EPRA14DV3 / ETBX16E(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

EPRA14DW1 / ETBX16E(6V/9W)
Configure model
Model name
EPRA14DW1 / ETBX16E(6V/9W)
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

EPRA14DV3 / ETVH16S18E(6V/9W)
Configure model
Model name
EPRA14DV3 / ETVH16S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.62

Heating up time

1:07 h:min

Standby power input

34.2 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DW1 / ETVH16S18E(6V/9W)
Configure model
Model name
EPRA14DW1 / ETVH16S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

106 %

COP

2.51

Heating up time

1:07 h:min

Standby power input

42.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DV3 / ETVX16S18E(6V/9W)
Configure model
Model name
EPRA14DV3 / ETVX16S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.62

Heating up time

1:07 h:min

Standby power input

34.2 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DW1 / ETVX16S18E(6V/9W)
Configure model
Model name
EPRA14DW1 / ETVX16S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

106 %

COP

2.51

Heating up time

1:07 h:min

Standby power input

42.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DV3 / ETVZ16S18E(6V/9W)
Configure model
Model name
EPRA14DV3 / ETVZ16S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.62

Heating up time

1:07 h:min

Standby power input

34.2 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DW1 / ETVZ16S18E(6V/9W)
Configure model
Model name
EPRA14DW1 / ETVZ16S18E(6V/9W)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

106 %

COP

2.51

Heating up time

1:07 h:min

Standby power input

42.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DV3 / ETVH16S18E(6V/9W) + cooling kit
Configure model
Model name
EPRA14DV3 / ETVH16S18E(6V/9W) + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.62

Heating up time

1:07 h:min

Standby power input

34.2 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DW1 / ETVH16S18E(6V/9W) + cooling kit
Configure model
Model name
EPRA14DW1 / ETVH16S18E(6V/9W) + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

106 %

COP

2.51

Heating up time

1:07 h:min

Standby power input

42.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DV3 / ETVH16SU18E6V
Configure model
Model name
EPRA14DV3 / ETVH16SU18E6V
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.62

Heating up time

1:07 h:min

Standby power input

34.2 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DW1 / ETVH16SU18E6V
Configure model
Model name
EPRA14DW1 / ETVH16SU18E6V
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

106 %

COP

2.51

Heating up time

1:07 h:min

Standby power input

42.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DV37 / ETBH16E(6V/9W)7
Configure model
Model name
EPRA14DV37 / ETBH16E(6V/9W)7
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

EPRA14DW17 / ETBH16E(6V/9W)7
Configure model
Model name
EPRA14DW17 / ETBH16E(6V/9W)7
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

EPRA14DV37 / ETBX16E(6V/9W)7
Configure model
Model name
EPRA14DV37 / ETBX16E(6V/9W)7
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

EPRA14DW17 / ETBX16E(6V/9W)7
Configure model
Model name
EPRA14DW17 / ETBX16E(6V/9W)7
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

EPRA14DV37 / ETVH16S18E(6V/9W)7
Configure model
Model name
EPRA14DV37 / ETVH16S18E(6V/9W)7
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.62

Heating up time

1:07 h:min

Standby power input

34.2 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DW17 / ETVH16S18E(6V/9W)7
Configure model
Model name
EPRA14DW17 / ETVH16S18E(6V/9W)7
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

106 %

COP

2.51

Heating up time

1:07 h:min

Standby power input

42.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DV37 / ETVH16SU18E6V7
Configure model
Model name
EPRA14DV37 / ETVH16SU18E6V7
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.62

Heating up time

1:07 h:min

Standby power input

34.2 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DW17 / ETVH16SU18E6V7
Configure model
Model name
EPRA14DW17 / ETVH16SU18E6V7
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

106 %

COP

2.51

Heating up time

1:07 h:min

Standby power input

42.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DV37 / ETVX16S18E(6V/9W)7
Configure model
Model name
EPRA14DV37 / ETVX16S18E(6V/9W)7
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.62

Heating up time

1:07 h:min

Standby power input

34.2 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DW17 / ETVX16S18E(6V/9W)7
Configure model
Model name
EPRA14DW17 / ETVX16S18E(6V/9W)7
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

106 %

COP

2.51

Heating up time

1:07 h:min

Standby power input

42.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DV37 / ETVZ16S18E(6V/9W)7
Configure model
Model name
EPRA14DV37 / ETVZ16S18E(6V/9W)7
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.62

Heating up time

1:07 h:min

Standby power input

34.2 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DW17 / ETVZ16S18E(6V/9W)7
Configure model
Model name
EPRA14DW17 / ETVZ16S18E(6V/9W)7
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

106 %

COP

2.51

Heating up time

1:07 h:min

Standby power input

42.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DV37 / ETVH16S18E(6V/9W)7 + cooling kit
Configure model
Model name
EPRA14DV37 / ETVH16S18E(6V/9W)7 + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.69 kW

7.24 kW

El input

1.22 kW

2.41 kW

COP

4.67

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.99

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1038 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.1 kW

11.2 kW

COP Tj = -7°C

3.12

2.47

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.7 kW

6.9 kW

COP Tj = +2°C

4.44

3.56

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

5.7 kW

6.9 kW

COP Tj = +7°C

5.84

4.44

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

6 kW

6.2 kW

COP Tj = 12°C

7.4

5.72

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

11.1 kW

12.2 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.1 kW

12.2 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.4 kW

0 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

110 %

COP

2.62

Heating up time

1:07 h:min

Standby power input

34.2 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l

EPRA14DW17 / ETVH16S18E(6V/9W)7 + cooling kit
Configure model
Model name
EPRA14DW17 / ETVH16S18E(6V/9W)7 + cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.9 kW

7.24 kW

El input

1.23 kW

2.47 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.56 kW

Cooling capacity

6.9

EER

2.7

EN 14825

+7°C/+12°C

Pdesignc

6.9 kW

SEER

3.87

Pdc Tj = 35°C

6.9 kW

EER Tj = 35°C

2.7

Pdc Tj = 30°C

5.23 kW

EER Tj = 30°C

3.65

Cdc Tj = 30 °C

1

Pdc Tj = 25°C

5.05 kW

EER Tj = 25°C

4.58

Cdc Tj = 25 °C

1

Pdc Tj = 20°C

4.94 kW

EER Tj = 20°C

5.41

Cdc Tj = 20 °C

1

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1069 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

140 %

Prated

12.5 kW

12.5 kW

SCOP

4.71

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.7 kW

11.1 kW

COP Tj = -7°C

2.97

2.43

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

6.9 kW

6.7 kW

COP Tj = +2°C

4.94

3.52

Cdh Tj = +2 °C

1

1

Pdh Tj = +7°C

6.2 kW

6.5 kW

COP Tj = +7°C

5.95

4.54

Cdh Tj = +7 °C

1

1

Pdh Tj = 12°C

5.6 kW

5.2 kW

COP Tj = 12°C

7.07

5.97

Cdh Tj = +12 °C

1

1

Pdh Tj = Tbiv

10.7 kW

12.5 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.1 kW

12.5 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.88

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.4 kW

0 kW

Annual energy consumption Qhe

5479 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

106 %

COP

2.51

Heating up time

1:07 h:min

Standby power input

42.9 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

240 l