Certificate holders

Subtype

Volan 7

Certificate Holder
THERMAGEN sp. z o.o.
Ul. Warszawska 50
82-100 Nowy Dwór Gdański
Poland
Registration number
011-1W0530
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Volan 7
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,750 kg

Certification Date
01.06.2022
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 9 (as of 2021-03)
Generate PDF Export model CSV
  • Number of models 1

Models

Volan 7
Configure model
Model name
Volan 7
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.30 kW

2.80 kW

El input

0.64 kW

0.85 kW

COP

5.20

3.30

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

159 %

Prated

4.00 kW

3.60 kW

SCOP

5.11

4.04

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.02 kW

3.63 kW

COP Tj = +2°C

3.00

2.11

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.54 kW

2.41 kW

COP Tj = +7°C

6.15

3.79

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

1.23 kW

1.51 kW

COP Tj = 12°C

5.26

5.26

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

4.02 kW

3.63 kW

COP Tj = Tbiv

3.00

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.02 kW

3.63 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.00

2.11

WTOL

75 °C

75 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

8 W

8 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1045 kWh

1191 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

146 %

120 %

Prated

4.50 kW

4.30 kW

SCOP

3.72

3.07

Tbiv

-12 °C

-12 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

2.73 kW

2.64 kW

COP Tj = -7°C

3.69

2.79

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

1.64 kW

1.57 kW

COP Tj = +2°C

4.95

3.87

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

1.10 kW

1.27 kW

COP Tj = +7°C

4.73

4.64

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

1.25 kW

1.20 kW

COP Tj = 12°C

5.47

5.02

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

3.29 kW

3.07 kW

COP Tj = Tbiv

3.17

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.32 kW

3.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.09

2.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

75 °C

75 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

8 W

8 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.50 kW

4.30 kW

Annual energy consumption Qhe

2983 kWh

3458 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.32

3.09

COP Tj = -15°C (if TOL<-20°C)

3.09

2.40

Cdh Tj = -15 °C

1.000

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

135 %

Prated

4.10 kW

4.00 kW

SCOP

4.45

3.45

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.69 kW

3.47 kW

COP Tj = -7°C

2.96

2.21

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.26 kW

2.18 kW

COP Tj = +2°C

4.63

3.46

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

1.50 kW

1.37 kW

COP Tj = +7°C

5.61

4.46

Cdh Tj = +7 °C

0.97

0.97

Pdh Tj = 12°C

1.34 kW

1.45 kW

COP Tj = 12°C

5.79

5.57

Cdh Tj = +12 °C

0.96

0.96

Pdh Tj = Tbiv

3.69 kW

3.47 kW

COP Tj = Tbiv

2.96

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.63 kW

3.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.83

2.07

WTOL

75 °C

75 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

8 W

8 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.47 kW

0.66 kW

Annual energy consumption Qhe

1902 kWh

2396 kWh