Certificate holders

Subtype

Volan 9

Certificate Holder
THERMAGEN sp. z o.o.
Ul. Warszawska 50
82-100 Nowy Dwór Gdański
Poland
Registration number
011-1W0531
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Volan 9
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,850 kg

Certification Date
01.06.2022
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 9 (as of 2021-03)
Generate PDF Export model CSV
  • Number of models 1

Models

Volan 9
Configure model
Model name
Volan 9
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.20 kW

4.10 kW

El input

0.84 kW

1.30 kW

COP

4.98

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

218 %

171 %

Prated

6.50 kW

6.00 kW

SCOP

5.53

4.35

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.47 kW

5.96 kW

COP Tj = +2°C

3.39

2.49

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

4.12 kW

3.92 kW

COP Tj = +7°C

5.38

3.88

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

4.92 kW

4.59 kW

COP Tj = 12°C

6.66

5.67

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

6.47 kW

5.96 kW

COP Tj = Tbiv

3.39

2.49

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.47 kW

5.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.39

2.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

0 W

0 W

PTO

9 W

9 W

PSB

8 W

8 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1570 kWh

1844 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

125 %

Prated

4.50 kW

4.50 kW

SCOP

3.78

3.20

Tbiv

-15 °C

-15 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

2.75 kW

2.48 kW

COP Tj = -7°C

3.80

2.88

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.12 kW

3.42 kW

COP Tj = +2°C

4.80

4.07

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.18 kW

4.06 kW

COP Tj = +7°C

6.13

5.26

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

2.26 kW

4.81 kW

COP Tj = 12°C

5.29

6.38

Cdh Tj = +12 °C

0.980

0.990

Pdh Tj = Tbiv

3.64 kW

3.71 kW

COP Tj = Tbiv

2.92

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.64 kW

3.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.92

2.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

0 W

0 W

PTO

9 W

9 W

PSB

8 W

8 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.50 kW

4.50 kW

Annual energy consumption Qhe

2936 kWh

3472 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.64

3.71

COP Tj = -15°C (if TOL<-20°C)

2.92

2.24

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

142 %

Prated

5.00 kW

5.00 kW

SCOP

4.57

3.63

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.32 kW

4.40 kW

COP Tj = -7°C

3.27

2.35

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

3.18 kW

3.41 kW

COP Tj = +2°C

4.49

3.58

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.07 kW

3.85 kW

COP Tj = +7°C

5.87

4.81

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.11 kW

4.79 kW

COP Tj = 12°C

6.96

6.11

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

5.03 kW

4.40 kW

COP Tj = Tbiv

3.01

2.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.03 kW

4.52 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.01

2.19

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

70 °C

70 °C

Poff

0 W

0 W

PTO

9 W

9 W

PSB

8 W

8 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.48 kW

Annual energy consumption Qhe

2258 kWh

2844 kWh