1,000 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
12.42 kW
11.85 kW
El input
2.75 kW
3.93 kW
COP
4.52
3.01
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
192 %
143 %
Prated
14.67 kW
13.90 kW
SCOP
5.00
3.76
Tbiv
4 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.42 kW
11.85 kW
COP Tj = +2°C
4.52
3.03
Cdh Tj = +2 °C
0.997
0.998
Pdh Tj = +7°C
12.73 kW
11.98 kW
COP Tj = +7°C
4.90
3.50
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
12.96 kW
12.22 kW
COP Tj = 12°C
5.31
4.22
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
12.57 kW
11.91 kW
COP Tj = Tbiv
4.73
3.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.42 kW
11.85 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.52
3.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.998
WTOL
65 °C
65 °C
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.25 kW
2.05 kW
Annual energy consumption Qhe
3922 kWh
4932 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
196 %
145 %
Prated
14.56 kW
14.18 kW
SCOP
5.09
3.83
Tbiv
-17 °C
-16 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
12.83 kW
12.02 kW
COP Tj = -7°C
5.02
3.63
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
12.95 kW
12.14 kW
COP Tj = +2°C
5.25
4.02
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
12.98 kW
12.32 kW
COP Tj = +7°C
5.40
4.39
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
12.99 kW
12.49 kW
COP Tj = 12°C
5.44
4.70
Cdh Tj = +12 °C
0.996
0.996
Pdh Tj = Tbiv
12.65 kW
11.94 kW
COP Tj = Tbiv
4.81
3.37
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.42 kW
11.85 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.52
3.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.14 kW
2.33 kW
Annual energy consumption Qhe
7049 kWh
9120 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
142 %
Prated
13.51 kW
14.79 kW
SCOP
4.94
3.74
Tbiv
-8 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.49 kW
11.90 kW
COP Tj = -7°C
4.64
3.22
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
12.75 kW
12.06 kW
COP Tj = +2°C
4.92
3.76
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
12.94 kW
12.17 kW
COP Tj = +7°C
5.22
4.10
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
13.00 kW
12.40 kW
COP Tj = 12°C
5.46
4.53
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
12.47 kW
11.94 kW
COP Tj = Tbiv
4.59
3.38
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.42 kW
11.85 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.52
3.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.09 kW
2.94 kW
Annual energy consumption Qhe
5650 kWh
8167 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
16.19 kW
15.12 kW
El input
2.81 kW
4.05 kW
COP
5.76
3.73
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
242 %
185 %
Prated
17.53 kW
18.01 kW
SCOP
6.25
4.82
Tbiv
3 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
16.26 kW
15.12 kW
COP Tj = +2°C
5.78
3.73
Cdh Tj = +2 °C
0.997
0.998
Pdh Tj = +7°C
16.38 kW
15.69 kW
COP Tj = +7°C
6.12
4.44
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
16.50 kW
16.18 kW
COP Tj = 12°C
6.58
5.50
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
16.28 kW
15.44 kW
COP Tj = Tbiv
5.89
4.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
16.26 kW
15.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.78
3.73
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.27 kW
2.89 kW
Annual energy consumption Qhe
3749 kWh
4991 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
246 %
189 %
Prated
18.25 kW
17.85 kW
SCOP
6.35
4.92
Tbiv
-18 °C
-17 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
16.44 kW
15.78 kW
COP Tj = -7°C
6.26
4.61
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
16.49 kW
16.06 kW
COP Tj = +2°C
6.51
5.19
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
16.50 kW
16.26 kW
COP Tj = +7°C
6.69
5.71
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
16.50 kW
16.40 kW
COP Tj = 12°C
6.73
6.14
Cdh Tj = +12 °C
0.996
0.996
Pdh Tj = Tbiv
16.33 kW
15.50 kW
COP Tj = Tbiv
6.02
4.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
16.26 kW
15.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.78
3.73
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.99 kW
2.73 kW
Annual energy consumption Qhe
7088 kWh
8942 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
240 %
183 %
Prated
16.92 kW
18.30 kW
SCOP
6.20
4.78
Tbiv
-9 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
16.29 kW
15.38 kW
COP Tj = -7°C
5.91
4.02
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
16.40 kW
15.88 kW
COP Tj = +2°C
6.17
4.79
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
16.49 kW
16.11 kW
COP Tj = +7°C
6.47
5.31
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
16.50 kW
16.32 kW
COP Tj = 12°C
6.76
5.90
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
16.27 kW
15.48 kW
COP Tj = Tbiv
5.82
4.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
16.26 kW
15.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.78
3.73
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
6 W
6 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.66 kW
3.18 kW
Annual energy consumption Qhe
5640 kWh
7910 kWh