0,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.83 kW
6.28 kW
El input
1.22 kW
2.05 kW
COP
4.79
3.07
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
57 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
197 %
146 %
Prated
4.92 kW
4.71 kW
SCOP
5.00
3.71
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.35 kW
4.17 kW
COP Tj = -7°C
3.23
2.32
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.66 kW
2.67 kW
COP Tj = +2°C
4.92
3.66
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.06 kW
2.57 kW
COP Tj = +7°C
6.18
4.64
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
2.35 kW
2.83 kW
COP Tj = 12°C
8.29
6.32
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
4.35 kW
4.17 kW
COP Tj = Tbiv
3.23
2.32
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.95 kW
4.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.84
2.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
67 °C
67 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
42 W
42 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.01 kW
Annual energy consumption Qhe
2031 kWh
2623 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.38 kW
4.50 kW
El input
0.88 kW
1.53 kW
COP
4.97
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
57 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
191 %
137 %
Prated
4.51 kW
4.52 kW
SCOP
4.84
3.49
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.99 kW
4.00 kW
COP Tj = -7°C
3.18
2.25
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.43 kW
2.52 kW
COP Tj = +2°C
4.69
3.44
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.91 kW
1.66 kW
COP Tj = +7°C
6.42
4.37
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.28 kW
2.09 kW
COP Tj = 12°C
8.82
6.36
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
3.99 kW
4.00 kW
COP Tj = Tbiv
3.18
2.25
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.47 kW
4.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.79
1.98
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
41 W
41 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.04 kW
0.12 kW
Annual energy consumption Qhe
1928 kWh
2681 kWh