Certificate holders

Subtype

Jersey 7

Certificate Holder
ait-deutschland GmbH
Industriestr. 3
95359 Kasendorf
Germany
Registration number
041-K001-48 / 01
Certification Body
BRE
Subtype title
Jersey 7
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,550 kg

Certification Date
29.04.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Testing laboratory
Universität Stuttgart, Prüfstelle HLK am Institut für Gebäudeenergetik, Thermotechnik und Energiespeicherung (IGTE), DE
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

alpha innotec Jersey 7-1
Configure model
Model name
alpha innotec Jersey 7-1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.87 kW

3.09 kW

El input

0.85 kW

1.21 kW

COP

4.54

2.55

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

162 %

123 %

Prated

8.20 kW

7.49 kW

SCOP

4.13

3.15

Tbiv

-8 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.18 kW

6.55 kW

COP Tj = -7°C

2.65

2.03

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.14 kW

3.70 kW

COP Tj = +2°C

3.99

3.00

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.63 kW

2.49 kW

COP Tj = +7°C

5.34

4.25

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

2.24 kW

2.16 kW

COP Tj = 12°C

7.15

5.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.22 kW

6.55 kW

COP Tj = Tbiv

2.59

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.94 kW

5.26 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

58 °C

58 °C

Poff

41 W

41 W

PTO

45 W

45 W

PSB

45 W

45 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.26 kW

2.33 kW

Annual energy consumption Qhe

4102 kWh

4917 kWh

NOVELAN Jabbah 7-1
Configure model
Model name
NOVELAN Jabbah 7-1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.87 kW

3.09 kW

El input

0.85 kW

1.21 kW

COP

4.54

2.55

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

162 %

123 %

Prated

8.20 kW

7.49 kW

SCOP

4.13

3.15

Tbiv

-8 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.18 kW

6.55 kW

COP Tj = -7°C

2.65

2.03

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.14 kW

3.70 kW

COP Tj = +2°C

3.99

3.00

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.63 kW

2.49 kW

COP Tj = +7°C

5.34

4.25

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

2.24 kW

2.16 kW

COP Tj = 12°C

7.15

5.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.22 kW

6.55 kW

COP Tj = Tbiv

2.59

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.94 kW

5.26 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

58 °C

58 °C

Poff

41 W

41 W

PTO

45 W

45 W

PSB

45 W

45 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.26 kW

2.33 kW

Annual energy consumption Qhe

4102 kWh

4917 kWh

alpha innotec Jersey 7-2
Configure model
Model name
alpha innotec Jersey 7-2
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.87 kW

3.09 kW

El input

0.85 kW

1.21 kW

COP

4.54

2.55

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

162 %

123 %

Prated

8.20 kW

7.49 kW

SCOP

4.13

3.15

Tbiv

-8 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.18 kW

6.55 kW

COP Tj = -7°C

2.65

2.03

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.14 kW

3.70 kW

COP Tj = +2°C

3.99

3.00

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.63 kW

2.49 kW

COP Tj = +7°C

5.34

4.25

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

2.24 kW

2.16 kW

COP Tj = 12°C

7.15

5.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.22 kW

6.55 kW

COP Tj = Tbiv

2.59

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.94 kW

5.26 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

58 °C

58 °C

Poff

41 W

41 W

PTO

45 W

45 W

PSB

45 W

45 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.26 kW

2.33 kW

Annual energy consumption Qhe

4102 kWh

4917 kWh

NOVELAN Jabbah 7-2
Configure model
Model name
NOVELAN Jabbah 7-2
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.87 kW

3.09 kW

El input

0.85 kW

1.21 kW

COP

4.54

2.55

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

162 %

123 %

Prated

8.20 kW

7.49 kW

SCOP

4.13

3.15

Tbiv

-8 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.18 kW

6.55 kW

COP Tj = -7°C

2.65

2.03

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.14 kW

3.70 kW

COP Tj = +2°C

3.99

3.00

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.63 kW

2.49 kW

COP Tj = +7°C

5.34

4.25

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

2.24 kW

2.16 kW

COP Tj = 12°C

7.15

5.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.22 kW

6.55 kW

COP Tj = Tbiv

2.59

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.94 kW

5.26 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

58 °C

58 °C

Poff

41 W

41 W

PTO

45 W

45 W

PSB

45 W

45 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.26 kW

2.33 kW

Annual energy consumption Qhe

4102 kWh

4917 kWh