Certificate holders

Subtype

VWL 85/3 A 230V

Certificate Holder
Vaillant Deutschland GmbH & Co KG
Berghauser Straße 40
42859 Remscheid
Germany
Registration number
40045831
Certification Body
VDE Testing and Certification Institute GmbH
Subtype title
VWL 85/3 A 230V
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,950 kg

Certification Date
22.02.2017
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

VWL 85/3 A 230V
Configure model
Model name
VWL 85/3 A 230V
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.07 kW

6.34 kW

El input

1.74 kW

2.38 kW

COP

4.07

2.66

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

60 dB(A)

60 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

152 %

Prated

6.94 kW

5.49 kW

SCOP

5.27

3.87

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.94 kW

5.49 kW

COP Tj = +2°C

2.75

2.08

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.58 kW

3.65 kW

COP Tj = +7°C

4.84

3.29

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.49 kW

3.27 kW

COP Tj = 12°C

6.35

5.03

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

6.94 kW

5.49 kW

COP Tj = Tbiv

2.75

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.94 kW

5.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.75

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

63 °C

63 °C

Poff

4 W

4 W

PTO

4 W

4 W

PSB

5 W

5 W

PCK

6 W

6 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1760 kWh

1894 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

60 dB(A)

60 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

120 %

Prated

6.45 kW

3.73 kW

SCOP

3.90

3.07

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.71 kW

3.25 kW

COP Tj = -7°C

2.34

1.99

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.57 kW

2.22 kW

COP Tj = +2°C

3.83

2.91

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.98 kW

2.81 kW

COP Tj = +7°C

5.10

4.02

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

3.54 kW

3.49 kW

COP Tj = 12°C

6.70

5.69

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

5.71 kW

3.73 kW

COP Tj = Tbiv

2.34

1.76

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.51 kW

3.73 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.25

1.76

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

63 °C

63 °C

Poff

4 W

4 W

PTO

4 W

4 W

PSB

5 W

5 W

PCK

6 W

6 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.94 kW

0.00 kW

Annual energy consumption Qhe

3420 kWh

2508 kWh