1,950 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.07 kW
6.34 kW
El input
1.74 kW
2.38 kW
COP
4.07
2.66
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
60 dB(A)
60 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
208 %
152 %
Prated
6.94 kW
5.49 kW
SCOP
5.27
3.87
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.94 kW
5.49 kW
COP Tj = +2°C
2.75
2.08
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.58 kW
3.65 kW
COP Tj = +7°C
4.84
3.29
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.49 kW
3.27 kW
COP Tj = 12°C
6.35
5.03
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
6.94 kW
5.49 kW
COP Tj = Tbiv
2.75
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.94 kW
5.49 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.75
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
63 °C
63 °C
Poff
4 W
4 W
PTO
4 W
4 W
PSB
5 W
5 W
PCK
6 W
6 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1760 kWh
1894 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
60 dB(A)
60 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
153 %
120 %
Prated
6.45 kW
3.73 kW
SCOP
3.90
3.07
Tbiv
-7 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.71 kW
3.25 kW
COP Tj = -7°C
2.34
1.99
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.57 kW
2.22 kW
COP Tj = +2°C
3.83
2.91
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.98 kW
2.81 kW
COP Tj = +7°C
5.10
4.02
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
3.54 kW
3.49 kW
COP Tj = 12°C
6.70
5.69
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
5.71 kW
3.73 kW
COP Tj = Tbiv
2.34
1.76
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.51 kW
3.73 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.76
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
63 °C
63 °C
Poff
4 W
4 W
PTO
4 W
4 W
PSB
5 W
5 W
PCK
6 W
6 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.94 kW
0.00 kW
Annual energy consumption Qhe
3420 kWh
2508 kWh