1,800 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
4.40 kW
3.94 kW
El input
0.97 kW
1.45 kW
COP
4.53
2.73
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
58 dB(A)
58 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
150 %
Prated
5.80 kW
4.90 kW
SCOP
5.05
3.83
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.45 kW
4.53 kW
COP Tj = +2°C
2.80
2.06
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.37 kW
3.63 kW
COP Tj = +7°C
4.44
3.42
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
4.51 kW
4.38 kW
COP Tj = 12°C
6.36
4.81
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
5.45 kW
4.53 kW
COP Tj = Tbiv
2.80
2.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.45 kW
4.53 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.80
2.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
6 W
6 W
PTO
6 W
6 W
PSB
5 W
5 W
PCK
5 W
5 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1535 kWh
1708 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
58 dB(A)
58 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
149 %
119 %
Prated
5.71 kW
4.22 kW
SCOP
3.79
3.05
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-7 °C
Pdh Tj = -7°C
4.67 kW
3.74 kW
COP Tj = -7°C
2.45
2.00
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
2.90 kW
2.87 kW
COP Tj = +2°C
3.85
3.07
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.38 kW
3.81 kW
COP Tj = +7°C
4.62
4.15
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
4.53 kW
4.47 kW
COP Tj = 12°C
6.55
5.21
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
4.67 kW
3.74 kW
COP Tj = Tbiv
2.45
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.62 kW
3.74 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
2.00
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
60 °C
60 °C
Poff
6 W
6 W
PTO
6 W
6 W
PSB
5 W
5 W
PCK
5 W
5 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.09 kW
4.22 kW
Annual energy consumption Qhe
3110 kWh
2860 kWh