Certificate holders

Subtype

VWL 55/3 A 230V

Certificate Holder
Vaillant Deutschland GmbH & Co KG
Berghauser Straße 40
42859 Remscheid
Germany
Registration number
40045821
Certification Body
VDE Prüf- und Zertifizierungsinstitut GmbH
Subtype title
VWL 55/3 A 230V
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,800 kg

Certification Date
22.02.2017
Testing basis
DIN EN 14825:2013-12; EN 14825:2013
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

VWL 55/3 A 230V
Configure model
Model name
VWL 55/3 A 230V
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.40 kW

3.94 kW

El input

0.97 kW

1.45 kW

COP

4.53

2.73

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

58 dB(A)

58 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

150 %

Prated

5.80 kW

4.90 kW

SCOP

5.05

3.83

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.45 kW

4.53 kW

COP Tj = +2°C

2.80

2.06

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.37 kW

3.63 kW

COP Tj = +7°C

4.44

3.42

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

4.51 kW

4.38 kW

COP Tj = 12°C

6.36

4.81

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

5.45 kW

4.53 kW

COP Tj = Tbiv

2.80

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.45 kW

4.53 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

6 W

6 W

PTO

6 W

6 W

PSB

5 W

5 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1535 kWh

1708 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

58 dB(A)

58 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

149 %

119 %

Prated

5.71 kW

4.22 kW

SCOP

3.79

3.05

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-7 °C

Pdh Tj = -7°C

4.67 kW

3.74 kW

COP Tj = -7°C

2.45

2.00

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.90 kW

2.87 kW

COP Tj = +2°C

3.85

3.07

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.38 kW

3.81 kW

COP Tj = +7°C

4.62

4.15

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

4.53 kW

4.47 kW

COP Tj = 12°C

6.55

5.21

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

4.67 kW

3.74 kW

COP Tj = Tbiv

2.45

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.62 kW

3.74 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.37

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

6 W

6 W

PTO

6 W

6 W

PSB

5 W

5 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.09 kW

4.22 kW

Annual energy consumption Qhe

3110 kWh

2860 kWh