Certificate holders

Subtype

DAIKIN ALTHERMA 3 GEO 10KW

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0338
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA 3 GEO 10KW
Driving energy
n/a
Heat Pump Type
Brine/Water
Refrigerant
R32
Mass of Refrigerant

1,700 kg

Certification Date
14.06.2019
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 8

Models

EGSAH10D9W _1P
Configure model
Model name
EGSAH10D9W _1P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.49 kW

5.6 kW

El input

1.17 kW

1.95 kW

COP

4.7

2.87

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

158 %

Prated

8.5 kW

8.5 kW

SCOP

5.32

4.15

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.97 kW

5.43 kW

COP Tj = -7°C

5.45

3.92

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

3.05 kW

3.32 kW

COP Tj = +2°C

5.49

4.58

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.11 kW

2.07 kW

COP Tj = +7°C

5.74

4.73

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.19 kW

0.98 kW

COP Tj = 12°C

4.64

3.82

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3938 kWh

5047 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

152 %

Prated

8.5 kW

8.5 kW

SCOP

5.12

4.00

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.67 kW

7.45 kW

COP Tj = -7°C

4.51

3.15

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.59 kW

4.68 kW

COP Tj = +2°C

5.43

4.09

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.93 kW

2.98 kW

COP Tj = +7°C

5.38

4.54

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.36 kW

1.37 kW

COP Tj = 12°C

5.1

4.59

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3428 kWh

4393 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EGSAH10D9W _3P
Configure model
Model name
EGSAH10D9W _3P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.49 kW

5.6 kW

El input

1.17 kW

1.95 kW

COP

4.7

2.87

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

158 %

Prated

8.5 kW

8.5 kW

SCOP

5.32

4.15

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.97 kW

5.43 kW

COP Tj = -7°C

5.45

3.92

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

3.05 kW

3.32 kW

COP Tj = +2°C

5.49

4.58

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.11 kW

2.07 kW

COP Tj = +7°C

5.74

4.73

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.19 kW

0.98 kW

COP Tj = 12°C

4.64

3.82

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3938 kWh

5047 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

152 %

Prated

8.5 kW

8.5 kW

SCOP

5.12

4.00

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.67 kW

7.45 kW

COP Tj = -7°C

4.51

3.15

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.59 kW

4.68 kW

COP Tj = +2°C

5.43

4.09

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.93 kW

2.98 kW

COP Tj = +7°C

5.38

4.54

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.36 kW

1.37 kW

COP Tj = 12°C

5.1

4.59

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3428 kWh

4393 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EGSAH10UD9W _1P
Configure model
Model name
EGSAH10UD9W _1P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.49 kW

5.6 kW

El input

1.17 kW

1.95 kW

COP

4.7

2.87

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

207 %

159 %

Prated

8.5 kW

8.5 kW

SCOP

5.32

4.15

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.97 kW

5.43 kW

COP Tj = -7°C

5.45

3.92

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

3.05 kW

3.32 kW

COP Tj = +2°C

5.49

4.58

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.11 kW

2.07 kW

COP Tj = +7°C

5.74

4.73

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.19 kW

0.98 kW

COP Tj = 12°C

4.64

3.82

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3938 kWh

5047 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

152 %

Prated

8.5 kW

8.5 kW

SCOP

5.12

4.00

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.67 kW

7.45 kW

COP Tj = -7°C

4.51

3.15

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.59 kW

4.68 kW

COP Tj = +2°C

5.43

4.09

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.93 kW

2.98 kW

COP Tj = +7°C

5.38

4.54

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.36 kW

1.37 kW

COP Tj = 12°C

5.10

4.59

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3428 kWh

4393 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EGSAH10UD9W _3P
Configure model
Model name
EGSAH10UD9W _3P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.49 kW

5.6 kW

El input

1.17 kW

1.95 kW

COP

4.7

2.87

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

207 %

159 %

Prated

8.5 kW

8.5 kW

SCOP

5.32

4.15

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.97 kW

5.43 kW

COP Tj = -7°C

5.45

3.92

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

3.05 kW

3.32 kW

COP Tj = +2°C

5.49

4.58

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.11 kW

2.07 kW

COP Tj = +7°C

5.74

4.73

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.19 kW

0.98 kW

COP Tj = 12°C

4.64

3.82

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3938 kWh

5047 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

152 %

Prated

8.5 kW

8.5 kW

SCOP

5.12

4.00

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.67 kW

7.45 kW

COP Tj = -7°C

4.51

3.15

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.59 kW

4.68 kW

COP Tj = +2°C

5.43

4.09

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.93 kW

2.98 kW

COP Tj = +7°C

5.38

4.54

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.36 kW

1.37 kW

COP Tj = 12°C

5.10

4.59

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3428 kWh

4393 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EGSAX10D9W(G) _1P
Configure model
Model name
EGSAX10D9W(G) _1P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.49 kW

5.6 kW

El input

1.17 kW

1.95 kW

COP

4.7

2.87

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

207 %

159 %

Prated

8.5 kW

8.5 kW

SCOP

5.36

4.18

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.97 kW

5.43 kW

COP Tj = -7°C

5.45

3.92

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

3.05 kW

3.32 kW

COP Tj = +2°C

5.49

4.58

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.11 kW

2.07 kW

COP Tj = +7°C

5.74

4.73

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.19 kW

0.98 kW

COP Tj = 12°C

4.64

3.82

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3905 kWh

5015 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

154 %

Prated

8.5 kW

8.5 kW

SCOP

5.2

4.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.67 kW

7.45 kW

COP Tj = -7°C

4.51

3.15

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.59 kW

4.68 kW

COP Tj = +2°C

5.43

4.09

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.93 kW

2.98 kW

COP Tj = +7°C

5.38

4.54

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.36 kW

1.37 kW

COP Tj = 12°C

5.1

4.59

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3373 kWh

4339 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EGSAX10D9W(G) _3P
Configure model
Model name
EGSAX10D9W(G) _3P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.49 kW

5.6 kW

El input

1.17 kW

1.95 kW

COP

4.7

2.87

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

207 %

159 %

Prated

8.5 kW

8.5 kW

SCOP

5.36

4.18

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.97 kW

5.43 kW

COP Tj = -7°C

5.45

3.92

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

3.05 kW

3.32 kW

COP Tj = +2°C

5.49

4.58

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.11 kW

2.07 kW

COP Tj = +7°C

5.74

4.73

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.19 kW

0.98 kW

COP Tj = 12°C

4.64

3.82

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3905 kWh

5015 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

154 %

Prated

8.5 kW

8.5 kW

SCOP

5.2

4.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.67 kW

7.45 kW

COP Tj = -7°C

4.51

3.15

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.59 kW

4.68 kW

COP Tj = +2°C

5.43

4.09

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.93 kW

2.98 kW

COP Tj = +7°C

5.38

4.54

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.36 kW

1.37 kW

COP Tj = 12°C

5.1

4.59

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3373 kWh

4339 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EGSAX10UD9W _1P
Configure model
Model name
EGSAX10UD9W _1P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.49 kW

5.6 kW

El input

1.17 kW

1.95 kW

COP

4.7

2.87

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

207 %

159 %

Prated

8.5 kW

8.5 kW

SCOP

5.36

4.18

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.97 kW

5.43 kW

COP Tj = -7°C

5.45

3.92

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

3.05 kW

3.32 kW

COP Tj = +2°C

5.49

4.58

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.11 kW

2.07 kW

COP Tj = +7°C

5.74

4.73

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.19 kW

0.98 kW

COP Tj = 12°C

4.64

3.82

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3905 kWh

5015 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

154 %

Prated

8.5 kW

8.5 kW

SCOP

5.20

4.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.67 kW

7.45 kW

COP Tj = -7°C

4.51

3.15

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.59 kW

4.68 kW

COP Tj = +2°C

5.43

4.09

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.93 kW

2.98 kW

COP Tj = +7°C

5.38

4.54

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.36 kW

1.37 kW

COP Tj = 12°C

5.10

4.59

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3373 kWh

4339 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

EGSAX10UD9W _3P
Configure model
Model name
EGSAX10UD9W _3P
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.49 kW

5.6 kW

El input

1.17 kW

1.95 kW

COP

4.7

2.87

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

0.75 kW

0.49 kW

Cooling capacity

8.13

8.42

EER

10.8

17.13

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.4 kW

8.4 kW

SEER

12.93

13.87

Pdc Tj = 35°C

8.13 kW

8.42 kW

EER Tj = 35°C

10.8

17.13

Pdc Tj = 30°C

6.56 kW

6.13 kW

EER Tj = 30°C

15.17

17.1

Cdc Tj = 30 °C

0.97

0.96

Pdc Tj = 25°C

4.02 kW

3.77 kW

EER Tj = 25°C

15.98

14.26

Cdc Tj = 25 °C

0.94

0.94

Pdc Tj = 20°C

3.28 kW

3.57 kW

EER Tj = 20°C

12.99

16.42

Cdc Tj = 20 °C

0.94

0.93

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

390 kWh

363 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

207 %

159 %

Prated

8.5 kW

8.5 kW

SCOP

5.36

4.18

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.97 kW

5.43 kW

COP Tj = -7°C

5.45

3.92

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

3.05 kW

3.32 kW

COP Tj = +2°C

5.49

4.58

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.11 kW

2.07 kW

COP Tj = +7°C

5.74

4.73

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.19 kW

0.98 kW

COP Tj = 12°C

4.64

3.82

Cdh Tj = +12 °C

1.0

1.0

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3905 kWh

5015 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

154 %

Prated

8.5 kW

8.5 kW

SCOP

5.20

4.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.67 kW

7.45 kW

COP Tj = -7°C

4.51

3.15

Cdh Tj = -7 °C

1

1

Pdh Tj = +2°C

4.59 kW

4.68 kW

COP Tj = +2°C

5.43

4.09

Cdh Tj = +2 °C

1.0

1.0

Pdh Tj = +7°C

2.93 kW

2.98 kW

COP Tj = +7°C

5.38

4.54

Cdh Tj = +7 °C

1.0

1.0

Pdh Tj = 12°C

1.36 kW

1.37 kW

COP Tj = 12°C

5.10

4.59

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

8.55 kW

8.49 kW

COP Tj = Tbiv

4.29

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

8.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.85

WTOL

35 °C

55 °C

Poff

15 W

15 W

PTO

24 W

24 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

3373 kWh

4339 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

117 %

COP

2.82

Heating up time

1:43 h:min

Standby power input

26.2 W

Reference hot water temperature

53.0 °C

Mixed water at 40°C

239 l